Great technician—Super knowledgeable and personable. It was a pleasure dealing with Kurt.


Brian B.

Brian B.

Performed heating maintenance, cleaned burners and flame sensor, inspected heat exchanger. Checked boiler pressure and temperature, adjusted boiler pressure to 20 psi. Inspected venting. Started boiler, measured fuel pressures. Tested limit and safety switches. Performed combustion test.

Near Saratoga Rd, Berwyn, PA 19312
Brian B.

Brian B.

Performed heating maintenance, checked media air filters. Cleaned burners and flame sensors, inspected heat exchangers. Checked voltage, amperage and electrical connections. Started gas furnaces, tested limit and safety switches. Performed combustion test. Checked operation and temperature rise.

Near Bodine Rd, Berwyn, PA 19312
Kurt M.

Kurt M.

Found that tenet said when oil boiler kicks on sometimes she can smell exahaust. Found some soot in the boiler. Boiler could be cleaned. She said she did not see any smoke in the house just could smell it when it first kicks on. Called landlord let him know we will need to come back to perform the maintenance. Sent him over pricing in an email. Boiler needs cleaned but is not extremely sooted up.

Near Greene Rd, Berwyn, PA 19312
Kurt M.

Kurt M.

Performed precision a/c tune up on trane heat pump system. Replaced 20x22x1 air filter. Checked all electrical conections and components. Blew out condensate drain drain. Checked temperature split at indoor unit. Checked refrigerant pressures and temperatures at indoor and outdoor units. System is working fine at time of inspection.

Near Carol Ln, Berwyn, PA 19312
Brian B.

Brian B.

Checked no cooling complaint, found wet switch tripped but no water is in the pan. Reset wet switch, started air conditioner and checked refrigerant charge and temperature drop across coil.

Near Saratoga Rd, Berwyn, PA 19312
Kurt M.

Kurt M.

Performed 6 month inspection on mini split system for the basement, and performed 2 precision a/c tune ups on 2 amana a/c systems. Cleaned washable filters on mini split system, replaced 2 Aprilaire 413 air filters on 1st and 2nd floor a/c systems. Blew out all condensation drains. Checked temperature split on all a/c systems. Checked refrigerant pressures and temperatures at indoor and outdoor units. Systems are working fine at time of inspection.

Near Bodine Rd, Berwyn, PA 19312
Christopher B.

Christopher B.

Performed Quality Assurance on Daikin Mini Split system. Reviewed installation with homeowner. Tested unit in both heating and cooling modes. Completed checklist form in system.

Near Leopard Rd, Berwyn, PA 19312
Kurt M.

Kurt M.

Installed new txv at air handler. Also put down 3/4 plywood in the attic for walkway. After installing new valve, pressure tested and leak checked at 200 psi nitrogen. Put system on vacuum pump and pump system down to 400 microns. Released charge pulled back in condenser and performed quality assurance inspection. Temperature inside was a little cool during testing process only 62 degrees. Checked all electrical conections and components. Checked refrigerant pressures at outdoor unit. They were 206/ 104 with a subcooling of 26 and a super heat of 15. Covered outdoor fan and pressures were changing with fan being covered. System is working fine at time of service. 24x24x1 air filter is clean.

Near Saratoga Rd, Berwyn, PA 19312
Paul W.

Paul W.

Reclaimed and removed old equipment. Leveled new condensate pad and installed new Amana condenser with new disconnect and whip. Flushed lineset and brazed in with nitrogen. Installed new Amana air handler and brazed in with nitrogen. Pressure tested to 300 and evacuated to 132 microns. Reconnected electric with new disconnect and tied in low volt wires with ez trap and wet switch safteys. Reconnected supply and return ducts and sealed. Reconnected condensate lines. Installed new Honeywell t6 thermostat. Went to test system and found bad txv from factory. Will return to replace and test again.

Near Saratoga Rd, Berwyn, PA 19312
Paul W.

Paul W.

Reclaimed and removed old equipment. Installed new daikin heat pump on new leveled pad and ductless head. Installed new whip, disconnect, and surge protector. Installed new lineset and flared into both units with flare tite seals. Pressure tested to 400 psi and checked with bubbles. Evacuated down to 65 microns. Replaced all linehide and installed new pump for condensate. Tested system operation. System running perfectly at time of install.

Near Leopard Rd, Berwyn, PA 19312
Luis T.

Luis T.

Performed ac tune up check electrical low and high ok replace air filter check blower and coil flushed drain ok check outdoor unit refrigerant pressures capacitor and contactor ok noticed condenser fan motor pulling 1.5 amps and rated at 1.5 informed customer and recommended having system replace bill to come out on Wednesday at 10 am for new system replacement attic

Near Saratoga Rd, Berwyn, PA 19312
Luis T.

Luis T.

Daiken mini split unit not working, upon arrival found unit off, after talking to customer, they said unit was not coming for cooling or heating, set unit for heating and 86, unit came on check supply and rerun temp supply 120 return 70, explained to customer that mini split ac mode does not operate when outdoor temperature is below 50 but also by having dirty filters and blower housing unit runs below freezing and prevents the unit from coming, blower housing/wheel and coil needs to be cleaned, and also unit need to come off the wall to insulate both lines behind unit, if new piping is required we will informed customer additional cost will be required if new piping is needed, emailed proposal for repairs removed indoor unit from wall insulate lines and clean blower wheel, also we will be sending proposal for new system replacement

Near Leopard Rd, Berwyn, PA 19312
Luis T.

Luis T.

Performed ac tune up check electrical low and high ok replace air filter, flushed drain test pump check blower cap ok check split, check outdoor unit refrigerant pressures capacitor and contactor ok, recommend adding hard start kit to unit quoted but customer would do it next year, also performed water test water has 10 grains of calcium and magnesium chlorine levels are in the middle emailed customer proposal for water treatment systems

Near First Ave, Berwyn, PA 19312
Kurt M.

Kurt M.

Found no surge protection on ecm blower motor for first floor or second floor blower. Added surge protection to both systems. Performed precision peco heat tune up on 2 Lennox heat pump systems. First floor system has a 20x20x5 filter, second floor air filter is 20x25x5(homeowner to replace both filters). Checked all electrical conections and components. Checked refrigerant pressures and temperatures at indoor and outdoor units. Both systems are working fine at time of inspection. Do recommend switching over to high efficiency propane systems, homeowners are not very comfortable with heat pump systems. Found no surge protection on second floor blower motor

Near Leopard Way, Berwyn, PA 19312
Kurt M.

Kurt M.

Performed precision heat tune up on trane heat pump. Replaced dirty 20x22x1 air filter. ( recommended to homeowner to change more often, showed her how to change it). Checked all electrical conections and components. Checked refrigerant pressures and temperatures at indoor and outdoor units. System is working fine at time of service. Installed surge protector.

Near Carol Ln, Berwyn, PA 19312
Luis T.

Luis T.

Ran 10inch Return to the new room as well as a 6 inch supply vent. Put in mini split with outdoor unit ran line hide new disconnect drain and refrigerant lines inside line hide ran new power wire and tied into electrical panel with new 20 amp double poll breaker unit was triple evacuated and held pressure for 25 minutes. Unit was vacuumed down to 100 microns and held for 20 minutes... system is charged and running to factory standards. Went over everything with customer.

Near Bodine Rd, Berwyn, PA 19312
Luis T.

Luis T.

Replace gas valve on first floor system test and cycle furnace ok check for gas leaks on work performed no leaks combustion test ok system is running at no issues

Near Bodine Rd, Berwyn, PA 19312
Luis T.

Luis T.

No heat return visit to continue troubleshooting, after checking gas pressures incoming and manifold, check all grounding, furnace drain, found out bad connection on gas valve, contact Amana tech support and both agreed that gas valve should be replaced,

Near Bodine Rd, Berwyn, PA 19312
Luis T.

Luis T.

No heat, found furnace running upon arrival, check heater operation and test ok check errors on history found E0 ignition lock out, check all electrical, ground wire ok, check pressure switch and tubing ok, could not get furnace to failed did not din any issues, talked to Amana Rep, and he recommend to check heat exchanger for any leaks, inspect exchanger found lot of areas with rust, looks like condensation is getting to exchanger, could not check exchanger with my camera we will need a High definition camera and try to inspect heat exchanger deeper, return visit is need to check heat exchanger

Near Bodine Rd, Berwyn, PA 19312
Luis T.

Luis T.

Installed new pressure switch under warranty. Also found one of the pressure switch hoses to be a little loose. Re secured pressure switch hose with zip tie to make tight connection. Ran furnace for about 20 minutes and had no issues with it cutting out on any error codes. Also checked outside exahaust vent for debris, vent is clear. As furnace was running it displayed an e3 error code which is high limit code. Increased fan speed by 5% trim to help with temp rise. Now have a 51 degree temperature rise. Homeowner also would like an estimate from our office to add supplies and returns downstairs off of existing duct work.

Near Bodine Rd, Berwyn, PA 19312
Christopher B.

Christopher B.

Service call that the Gas Furnace for the First Floor of the Home was not working. Upon arrival found furnace in the EO Error Code. Tested system and found Proper Pressure at the Front Door Pressure Switch. Pressure switch did not close on several attempts for the furnace to fire. The pressure switch began closing after several ignition retries. Exercised the Pressure Switch and the contacts were closing. Restarted system and cycled multiple times to ensure the Furnace was firing. Will follow up about replacement of the Pressure Switch.

Near Bodine Rd, Berwyn, PA 19312
Joseph D.

Joseph D.

Removed Reme air scrubbers and inspected cells. Found cells not connected properly to wiring harness. Reconnected sales for downstairs and upstairs unit and tested operation. Back to downstairs furnace and clean drain lines and install vent on condensate drain line. Removed and inspected and clean flame sensor. Removed pressure switch tubing line and inspected and found small crack, replaced tubing line. Checked over all wiring harnesses and connections, and tested grounds. Tested furnace to ensure proper operation.

Near Bodine Rd, Berwyn, PA 19312
Christopher B.

Christopher B.

Homeowner called about water damage on the ceiling. Found mold and growth in the Bathroom Linen Closet. Found area in attic where damage to the drywall was occurring. Found no signs of water present during visit. Inspected Vent Piping and Condensation Drain Line. Inspected Refrigerant Pipes to insure it was insulated. This area is directly below the Exhaust Pipe where it terminates out of the roof. The Roof Flashing May be leaking and the water is running down the exhaust pipe. Also checked Reme Halo Air Cleaners on both systems. Both Air Cleaners are receiving the 24 Volts but are not turning on. Checked Ballast Connections. Checked Transformer wiring on both units. Need to replace both Remes. When we return to install the Remes we will further diagnose the First Floor system.

Near Bodine Rd, Berwyn, PA 19312
Christopher B.

Christopher B.

Service call that the First Floor system was not heating. Upon arrival found Furnace in a E0 Lockout Code. While testing system, unit began to operate. Checked Pressures on the Pressure Switches. Cleaned Flame Sensor and measured Micro-Amps which were measuring about 1.5 Micro-Amps. Measured Resistance across the Ignitor at 66 Ohms. Cycled system multiple times to ensure it was firing properly.

Near Bodine Rd, Berwyn, PA 19312
Christopher B.

Christopher B.

Returned to site to install new Control Board. Turned Power off to system and removed the old Control Board. Mounted new Control Board and made all wiring connections. Reviewed Dip-Switch settings on system and set all Dip-Switches. Reviewed Wiring on system and put system in operation. Checked Pressure Switch Tubing. Tested system in Heating and Cooling Modes to insure that it was running properly. System Was responding to the thermostat properly and is operating to standards at this time. While inspecting system, found Reme Halo Air Cleaner was not operating. Checked unit and verified that it was receiving proper voltage. Would recommend replacement of the Cell Membrane on unit. Reme recommends replacement of cell membrane every 2 Years for optimal performance. Homeowner has purchased new Cell and is going to replace. After testing system, found the Fan was continuing to run between cycles. The thermostat was not calling for Fan but was receiving 24V signal at the Board on the G

Near Bodine Rd, Berwyn, PA 19312