When you need air conditioning, heating and water heater services in Honey Brook, PA, you need DiBiase Heating & Cooling Company. We’ve earned a reputation over the years for providing customer-first service you can count on.
We live by rock-solid values of integrity, honesty and quality. Read our reviews and find out why your neighbors think of our trusty frog mascot whenever they need local heating, air conditioning and water heater services in Honey Brook, PA.

Local Reviews
for Honey Brook, PA

DiBiase Heating and Cooling Company Rated 5.0 out of 5 stars based on 49 customer reviews


Annual Service Call




Review of DiBiase Heating and Cooling Company


Great Service




Review of DiBiase Heating and Cooling Company

On time and work completed as required. Service Tech was very professional and answered all the questions I had.


The service was great




Review of DiBiase Heating and Cooling Company


Great service




Review of DiBiase Heating and Cooling Company


Great service, knowledge, skillful repairman.




Review of DiBiase Heating and Cooling Company


Great Professional Service




Review of DiBiase Heating and Cooling Company

Outstanding visit. Technician was knowledgeable, professional and took time to explain everything in detail.


Great Service!




Review of DiBiase Heating and Cooling Company


excellent work




Review of DiBiase Heating and Cooling Company


Thoroughly satisfactory service




Review of DiBiase Heating and Cooling Company


Great service




Review of DiBiase Heating and Cooling Company


Exceptional Service!




Review of DiBiase Heating and Cooling Company

The technician, Louis, was prompt, curteous & very knowledgeable. We’re very pleased with his service & the information he shared with us. Thank you.


ACcheck and water question




Review of DiBiase Heating and Cooling Company

Always very satisfied with your service, thanks. ET


Great service at no cost!




Review of DiBiase Heating and Cooling Company


Always prompt and thorough.




Review of DiBiase Heating and Cooling Company

Chris is a very thorough and competent mechanic. I trust him to maintain our HVAC system.


Service Rating




Review of DiBiase Heating and Cooling Company


Chris & Tom performed our scheduled semi annual tune up in a professional manner.




Review of DiBiase Heating and Cooling Company


Great Service




Review of DiBiase Heating and Cooling Company

Very professional, courteous, and explained things in detail. Very neat and clean.


emergency repair




Review of DiBiase Heating and Cooling Company

Chris arrived earlier than scheduled, which was a good thing since it freed us up to do other things. Chris was courteous and proficient and got right to work. He analyzed the problem and did the necessary repairs to the condensate drain and was finished in a little over an hour.


Always great service




Review of DiBiase Heating and Cooling Company

Got some great advice about the filter, your men are always polite and clean about their work


Prompt service for warranty item




Review of DiBiase Heating and Cooling Company


Exceptional service!




Review of DiBiase Heating and Cooling Company

Chris did an excellent job. He’s very prompt & professional. Thanks for such great service!


Semi annual check up




Review of DiBiase Heating and Cooling Company

Technician was a nice young man. Left everything clean and neat just like a professional. He all took time to answer of couple of questions very throughly. Represent you folks well.


Dibiase service was great




Review of DiBiase Heating and Cooling Company

Our technician from Dibiase was great. Very professional, took the time to explain issues, was on time and did a great job fixing our heating issue. I would highly recommend Dibiase to anyone needing HVAC work.


Great service




Review of DiBiase Heating and Cooling Company

Nathan always gives us a thorough & professional service call. He knows his stuff.


Fall Service Call




Review of DiBiase Heating and Cooling Company

Diabese always call to schedule maintenance visit in a timely manner. Scheduled appointment on time and efficiently completed


Christopher B.

Christopher B.

Performed Quality Assurance On recently installed Amana AC and Evaporator Coil. Performed Inspection of System and completed Checklist. Homeowners were not home during inspection so I was unable to get feedback about the actual install.

Near Whitehorse Dr, Honey Brook, PA 19344
Christopher B.

Christopher B.

Performed Quality Assurance On Amana Installation. Reviewed with Homeowners operation of the Thermostat and Settings. Installed LP Low Pressure Switch onto the Gas Valve. Checked Gas Piping for Leaks. Inspected Condensation Drain Pipes that were accessible. Had homeowner sign financing paperwork and reviewed paperwork.

Near Cog Hill Dr, Honey Brook, PA 19344
Luis T.

Luis T.

New coil and ac install.. we installed a new amana coil inside, with out disconnecting venting we re attached supply plenum ran new condensate from coil with an ez trap wired in series with a new condensate pump for drain protection used 2 coz cartridges and blew out existing vinyl tubing was ran through finished basement couldn’t replace. Also re ran furnace drain with union for easy clean out. Outdoor unit was set and leveled on a new pad with a new whip and disconnect system was triple evacuated and vacuumed down to 325 microns.. all penetrations we’re sealed

Near Whitehorse Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Installed new gas furnace and heat pump. Inside we installed a new furnace and coil with an April air media filter size for replacement is #213. Modified the return and supply trunks to reconnect to main ducting. Installed a new April air humidifier 600 series. Installed water lines for humidifier as well shark bite fitting above the water heater with a shut off valve. We re connected the venting and installed an eztrap and condensate pump which are all wired in for saftey. A union was installed in all 3 lines for easy access. A junction box was installed for the high voltage wire and bx cabled wire was ran to a new 4x4 box with an outlet and switch. We re connected the gas line and ran new track pipe for the connections unit was converted to propane and pressures were adjusted. A low pressure switch was also installed in the unit. We ran new thermostat wire and refrigerant lines to the outdoor unit along with new vinyl tubing ran from the condensate pump to the discharge line and an

Near Windswept Ln, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac check up check electrical low and high ok check filter 413, flushed drain ok check outdoor unit 410 pressures contactor and capacitor ok cycle unit ok clean outdoor coil with water system ok

Near Cog Hill Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac check up, check electrical low and high ok replace filter, check blower cap reading little low, blower wheels needs to be clean, also Clear partially clogged drain trap, flushed with water ok check split ok, found inducer transition cracked, shield get replace, check outdoor unit r22 pressures ok capacitor and contactor ok cycle unit ok

Near Cog Hill Dr, Honey Brook, PA 19344
Luis T.

Luis T.

No ac, found unit off upon arrival, customer took a video of what was happening, condenser fan motor would not spin, turn ac on and check operation motor would not spin, check capacitor reading 5.05 mfd, try to spin motor, and work, motor staring to go bad, due to all problems customer has had would recommend replacing ac unit joe will send estimate for new ac unit

Near Whitehorse Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Installed amana single stage gas furnace and ac. Converted gas furnace to lp gas. Installed eztrap and wet switch for protection. Installed Honeywell lyric thermostat. Tested system in both heating and cooling. New amana system is running at manufacture specifications at time of install.

Near Cog Hill Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Found iced up coil and suction line, turned disconnect on the off and turned fan fan on, we need to came back to check 410 pressures due to history’s and age of system would be better to replace unit office will get back to customer to schedule return visit 5-30-19 luis added 2 lbs of 410 and also added dye to system supply temp 55 return temp 77 super heat 25 and subccoling 14

Near Whitehorse Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Performed 6 month inspections on two ac units, found wet switch tripped for attic unit, reset wet switch, clean filter for attic unit and for basement unit replace 15x25x1, both system were running at factory charge, added 1 1/2 lb 410 to attic and 1 lb for basement unit, check sub cooling and superheat ok target super heat for attic is 24 and current running at 21 super heat, for first floor unit target super heat is 19 and it is running at 20 both system are running at manufacturers specifications cycle both units ok supply temperature 52 return 75 for both units

Near Windswept Ln, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac check up, check electrical low and high ok check filter, need change, flushed drain clean and test pump ok also try to inspect vinyl tubing discharge location, is behind drywall, informed customer viny tubing is behind drywall, check split ok, outdoor unit 410 pressures ok capacitor and contactor ok cycle unit ok

Near Glen Loch Dr, Honey Brook, PA 19344
Christopher B.

Christopher B.

Returned to site to install a new Water Heater under warranty. Turned Supply water off to the Water Heater and disconnected Gas Line and Venting. Drained water heater and removed. Installed a new 50 Gallon Bradford White LP Power-vented Water Heater in the Auxiliary Drain Pan. Repiped a section of the Hot and Cold Water Lines. Reconnected Gas Line and used Leak Spray to to ensure their were no leak leaks once the Gas had been restored. Put Water Heater in operation and inspected to ensure proper operation. Recorded new Water Information into System.While onsite was informed that the Air Conditioner was not operating. Found the Thermostat was completely blank and had no power. Found the Wet Switch was tripped. Reset the Wet Switch and put system in operation to test. Inspected unit and found no water in Auxiliary Drain Pan. Allowed System to operate while Water Heater was being installed. Checked unit and found the Pan was filling with water and the attic insulation was wet. Checked

Near Summerlin Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Problem with outdoor temp registering on thermostat, check ohms reading on outdoor unit ambient sensor outdoor temps is 76 and ohm resd Mf is 10 K. Reattached sensor its place and now thermostat is registering 76 no issues were found and also per customer increase water heater temp from m 120 to 125 setting

Near Cog Hill Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac check up, check electrical low and high ok replace customer supplied filter, flushed drain ok check split ok outdoor unit r22 pressures ok capacitor and contactor ok, found burnt wires due to mice nest, informed customer and ok repairs, repairs wire connections on low and high voltage wires, after repairs cycle unit ok

Near Augusta Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Checked water leak from new water heater, found 1/4” of water in the safety pan and the sensor tripped the flood stop. Found water dripping from above the gas valve and water dripping from the power wires that run to the inducer. Also found the insulation above the gas valve is wet. Water tank is leaking will need to replace the water heater.Need to replace leaking water heater Bradford White model Rg1pv50s6x

Near Summerlin Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac check up, check electrical low and high ok, replace filter, cleared drain trap, recommended installing an ez trap, flushed drain with gallon of water coming out ok, check supply and return temp supply 50 return 69 outdoor unit capacitor and contactor ok r22 pressures ok outdoor temp 68 high side 160/55 sub cooling 16 and super heat 12 liquid line temp 71 and suction line temp 42 cycle unit ok

Near Summerlin Dr, Honey Brook, PA 19344
Luis T.

Luis T.

We installed a 2 stage furnace and single stage ac and coil. With a Honeywell T6 WiFi pro stat, we flushed the line sets and reused the thermostat wires. We re connected the supply plenum on top of the coil. The unit sat on a return box which we re used. We re connected to the drain lines and venting. We flushed the linesets and and re connected those as well preformed a pressure test at 352.6 psi for 25 minutes bubble tested for leaks a triple Evacuation was preformed and the unit reached a micron level of 452 microns. We charged 1 pound of 410a to the system and checked the system in both heating and cooling. Gas pressures were checked as well. Kurt will be back to install correct thermostat clip in the morning! Filter size 16x25x1. Delta t in cooling 25.2. .Day 2 water heater install, installed new water heater with expansion tank and checked for gas leaks and water leaks. Installed a 6 pin connector on new hvac unit. Water heater is working well.

Near Summerlin Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac check up, check electrical low and high ok check 413 filter ok flushed drain ok check split ok outdoor unit 410 pressures super heat 14 sub cooling 8 check capacitor and contactor ok coil is clean cycle unit ok

Near Augusta Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac tune up check electrical low and high ok flushed drain ok check split ok, filter ok, check outdoor unit r22 pressures ok txv system is running at 10 sub cooling and 14 super heat pressures 165/65 indoor temp 68 supply 50 outdoor temp 70 capacitor and contactor ok coil is clean cycle unit ok quoted for reme halo installation special pricing until May 31,

Near Augusta Dr, Honey Brook, PA 19344
Luis T.

Luis T.

No ac, indoor unit runs but no cold air come out, check blower and filter ok check outdoor unit, compressor a,ps 6 and fan motor 1 pressures 50/0 psig, informed customer about situation needs refrigerant mostly likely evaporator coil is leaking, quoted for leak search and to add refrigerant due to situation and age recommend doing complete system replacement

Near Cog Hill Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac tune up, electrical checked out good in door and outdoor, washed the filter now is good. Pressures all checked out good. Cleaned out condensation line and pan now flowing good.

Near Cog Hill Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac check up, check electrical low and high ok flushed drain ok replace filter, check split ok outdoor unit r22 pressures ok capacitor and contactor ok, capacitor is running little low rated 55 and reading 51.25 recommended installing ez trap customer declined repairs

Near Augusta Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac tune up, check electrical low and high ok replace filter, check split ok flushed drain line ok, noticed 6 in flue ninety 90 elbow getting very thinner, would recommend replacing six inch 90 degree elbow in the fall, check outdoor unit 410 pressures contactor and cap ok

Near Lippitt Rd, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac check up, check electrical low and high ok replace filter, flushed drain test pump ok, noticed ac would not come on, thermostat not working properly, quoted for new thermostat customer ok with price, check ac operation ok capacitor and contactor ok r22 pressures ok

Near Augusta Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Performed ac check up, check electrical low and high ok filter ok check split ok flushed drain ok, inspect blower wheel, recommend cleaning blower wheel, check outdoor unit r22 pressures ok capacitor and contactor ok cycle unit ok recommend replacing water heater Removed blower wheel and clean wheel and blower housing