When you need air conditioning, heating and water heater services in Honey Brook, PA, you need DiBiase Heating & Cooling Company. We’ve earned a reputation over the years for providing customer-first service you can count on.
We live by rock-solid values of integrity, honesty and quality. Read our reviews and find out why your neighbors think of our trusty frog mascot whenever they need local heating, air conditioning and water heater services in Honey Brook, PA.

Local Reviews
for Honey Brook, PA

DiBiase Heating and Cooling Company Rated 5.0 out of 5 stars based on 57 customer reviews


Prompt, professional service!




Review of DiBiase Heating and Cooling Company


Great service




Review of DiBiase Heating and Cooling Company


Great installation




Review of DiBiase Heating and Cooling Company

Mike and Andy completed the removal of our old mini split system and installed a new unit in less than a day. Work was performed in an extremely neat and meticulous manner.


Smooth operation




Review of DiBiase Heating and Cooling Company

Very efficient with times and service


Very professional, courteous service. Thanks so much!




Review of DiBiase Heating and Cooling Company


Always great service




Review of DiBiase Heating and Cooling Company

Luis was very polite and efficient, took his time and checked everything, I have always had good service from your company


Great service




Review of DiBiase Heating and Cooling Company

Very courteous. Great explanations


Accurate, timely fix




Review of DiBiase Heating and Cooling Company

Luis did a good job noticing a problem and applying a quick fix. I know that companies need to make a profit, but 6 times the cost of parts (found on the Internet) is extremely high, especially since the replacement/fix took about 30 minutes.


Annual Service Call




Review of DiBiase Heating and Cooling Company


Great Service




Review of DiBiase Heating and Cooling Company

On time and work completed as required. Service Tech was very professional and answered all the questions I had.


The service was great




Review of DiBiase Heating and Cooling Company


Great service




Review of DiBiase Heating and Cooling Company


Great service, knowledge, skillful repairman.




Review of DiBiase Heating and Cooling Company


Great Professional Service




Review of DiBiase Heating and Cooling Company

Outstanding visit. Technician was knowledgeable, professional and took time to explain everything in detail.


Great Service!




Review of DiBiase Heating and Cooling Company


excellent work




Review of DiBiase Heating and Cooling Company


Thoroughly satisfactory service




Review of DiBiase Heating and Cooling Company


Great service




Review of DiBiase Heating and Cooling Company


Exceptional Service!




Review of DiBiase Heating and Cooling Company

The technician, Louis, was prompt, curteous & very knowledgeable. We’re very pleased with his service & the information he shared with us. Thank you.


ACcheck and water question




Review of DiBiase Heating and Cooling Company

Always very satisfied with your service, thanks. ET


Great service at no cost!




Review of DiBiase Heating and Cooling Company


Always prompt and thorough.




Review of DiBiase Heating and Cooling Company

Chris is a very thorough and competent mechanic. I trust him to maintain our HVAC system.


Service Rating




Review of DiBiase Heating and Cooling Company


Chris & Tom performed our scheduled semi annual tune up in a professional manner.




Review of DiBiase Heating and Cooling Company


Great Service




Review of DiBiase Heating and Cooling Company

Very professional, courteous, and explained things in detail. Very neat and clean.


Paul W.

Paul W.

Installed a new amana heater. Converted to propane. Put in a new electrical box with a switch outlet. Reconnected gas with a low pressure switch. Reconnected condensate with new ez trap. Reconnected vent piping. Ran new line set and brazed in with nitrogen. Evacuated down to 110 microns. Installed new amana outdoor condenser. Installed new whip and disconnect. Reconnected supply ducting. Tested system and made necessary adjustments. System working great at time of install.

Near Augusta Dr, Honey Brook, PA 19344
Kurt M.

Kurt M.

Found that inside line hide it was not sealed outside at lineset penitration. Air temp is picked up at wall hung unit inside front cover. Homeowner supplied some insulation to push inside wall. Pushed some in lineset hole a sealed with silicone. Only thing I can’t see is how much insulation is in wall where unit is placed. Told homeowner the only solution I think to do is for him to add more insulation in the wall where unit is hung. Homeowner is going to see how it does for now. Found when it was 72 degrees in the room unit whould come on when it was set to 63 degrees. This is caused by wall being cold behind unit, checked temperature at wall.

Near Cog Hill Dr, Honey Brook, PA 19344
Luis T.

Luis T.

No heat, found unit off upon arrival, set thermostat to call for heat and check operation found igniter not glowing, check resistance no resistance open igniter, quoted for new igniter igniter/flame sensor two in one, customer ok repairs installed new igniter kit and test unit cycle heater ok performed room co test and reading o ppm

Near Cherokee Ln, Honey Brook, PA 19344
Brian B.

Brian B.

Found after putting thermostat on fan on found oil furnace psi motor trying to run , but not coming on. Found bad 115 volt blower motor and bent wheel. Called distributer and we should be able to get blower motor, wheel, and motor mount to secure it. Replace blower motor, wheel and mount. Removed blower assembly, removed motor, mount and wheel, installed new motor , mount and wheel. Installed new motor capacitor. Wired blower. Checked direction. Started oil furnace and checked operation, motor running at7.2 amps on high speed.

Near Lippitt Rd, Honey Brook, PA 19344
Kurt M.

Kurt M.

Found lp American standard gas furnace locking out on a code 3 pressure switch error code. When you remove the 3” intake pressure switch code went away and furnace will ignite. Used a borescope camera and could not see what was in the pipe. Used a shop vac and tried to pull a vacuum ethier way to vacuum out what is in the pipe. Was not able to remove the clogg vent pipes are in drywall. Furnace is working fine without the intake connected. Talked to homeowner about issue and is ok with solution does not want to cut drywall at this point.

Near Glen Loch Dr, Honey Brook, PA 19344
Christopher B.

Christopher B.

Completed Quality Assurance on Amana Gas Furnace/AC System. Completed checklist Form in system. Reviewed installation with homeowner. When we come back in the spring for the AC Tune Up bring a bag of stone and fill in under the pad and try to level.

Near Summerlin Dr, Honey Brook, PA 19344
Christopher B.

Christopher B.

Returned to site and removed the old Condensation Pump. Vinyl Tubing was very dirty also. Removed the old vinyl tubing and ran new Tubing from the Condensation Pump to the Wash Sink. Filled Pump multiple times to insure it was pumping and draining properly. Installed an Ecobee SI Thermostat and programmed for the system. Tested operation of system. Set Heat Differential setting on the thermostat at 2 Degrees. Reviewed thermostat operation with homeowner upon completion.

Near Barneston Rd, Honey Brook, PA 19344
Christopher B.

Christopher B.

Performed Precision Heating Tune Up on Gas Furnace system. Checked 16x25x1 Air Filter. Filter was clean and in good condition. Inspected Electrical Components and cleaned Furnace Drain Lines. Inspected Heat Exchanger and burners. Heat exchanger has heavy rust forming inside of its chambers. No visible signs of the heat Exchanger being damaged were found at this time, but as the metal continues to rusts it can cause damage to the Heat Exchanger. Burners are in good condition. Performed Combustion Analysis on Furnace. While noted on a previous visit, the Water Heater is about 12-13 years old. Due to the age, would recommend replacement of the Water Heater before any issues occur. Thank You for renewing your Service Membership with us today!

Near Augusta Dr, Honey Brook, PA 19344
Christopher B.

Christopher B.

Completed Quality Assurance on American Standard Furnace. Reviewed installation with homeowner. Completed Checklist Form in system. Homeowner wants a thermostat that has the “Temperature Overswing” feature. Need to verify if the Ecobee 4/Ecobee Lite have this feature. Need to follow up with customer about installing a new Thermostat, and what pricing would be involved since we just installed the T6 Pro during the install.

Near Barneston Rd, Honey Brook, PA 19344
Luis T.

Luis T.

Preformed precision heat tune up upon arrival the heater was working fine, upon further review I saw that the burners were rusted out and would start to cause issues, burners are ordered at Johnstones supply under dojka customer paid balance in full and will need to be scheduled for installation Replace burners. Shut off gas, removed gas valve and manifold, removed burner box. Pulled burners and installed new burners. Aligned burners. Installed burner box. Installed gas valve and manifold. Cycled furnace and checked operation ok.

Near Whitehorse Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Performed propane gas heater tune up, check electrical low and high ok replace high efficiency filter and also replaced hu pad and serviced humidifier, clean sensor inspect burners ok, check low and high stage on furnace combustion test cle furnace ok emailed price to add red link indoor sensor if customer is interested, master bedroom seems to be hotter than rest of the house

Near Augusta Dr, Honey Brook, PA 19344
Kurt M.

Kurt M.

Checked no heat, found no ignition, found power to ignitor but it will not heat up. Checked ignitor, found open. Need to replace ignitor, I do not have the correct ignitor need to return with correct part. Returned with the correct igniter patr# 903758 and replaced. Furnace fired right up and is back in operation with a temperature rise of 42 degrees.

Near Anthony Ln, Honey Brook, PA 19344
Luis T.

Luis T.

When I arrived found American standard gas furnace locked out on a code 3 pressure switch lockout code. Check each spade terminal to ground off of pressure switch and had 27 volts going thru switch . Unplugged molex conection at control board and pushed back in and it made connection and came on. Control board has a loose conection on the board suggested replacing board and switch in cas conections inside switch are wearing out. Furnace is working for now but told them it won’t probably stay working.11-7-19 luis installed new control board for furnace and also new pressure switch calibrated switch to close at 1.15 WC test and cycle furnace ok performed combustion test cycle ok,

Near Augusta Dr, Honey Brook, PA 19344
Christopher B.

Christopher B.

Performed Six Month Inspection on Amana Furnace. Replaced 16x25x1 Air Filter. Inspected System and checked Furnace Drain Lines. Put system in operation and performed Combustion Analysis on Furnace. Measured Manifold Gas Pressure on system. System is operating to standards at this time. The Air Filters supplied by Homeowner are slightly larger than the Air Filter that was installed even though they are the same size of 16x25x1. Was unable to fit the other Air Filters into the Filter slot. Filter we installed is a PrePleat Brand 16x25x1.

Near Cog Hill Dr, Honey Brook, PA 19344
Kurt M.

Kurt M.

Found pitted flame sensor, replaced flame sensor. Performed precision heat tune up on American standard gas furnace. Replaced 16x25x1 air filter. Checked all electrical conections and components. Blew out condensate drain. Checked gas pressure. Performed combustion test. Gas furnace is working fine at time of service.

Near Augusta Dr, Honey Brook, PA 19344
Kurt M.

Kurt M.

Performed precision heat tune up on American standard gas furnace. 16x25x1 air filter is clean. Found transition piece between inducer motor and heat exchanger leaking water. Found pitted flame sensor. Also found heat exchanger very rusted and corroded. Recommend replacing both furnace and a/c together. Also checked gas pressure and performed combustion test. Set up appointment with office for bill to give estimate on replacement.

Near Augusta Dr, Honey Brook, PA 19344
Kurt M.

Kurt M.

Found pitted flame sensor, replaced flame sensor. Also performed precision heat tune up on American standard gas furnace. Replaced 16x25x1 air filter. Checked all electrical conections and components. Blew out condensate drain. Checked gas pressure, and performed combustion test. Gas furnace is working fine at time of service. Also recommended replacement of lp gas water heater due to age of tank.

Near Augusta Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Installed new propane furnace and air conditioner replaced old line set and ran new line set customer requested we moved the thermostat so we did to his desired location with new wire. New pad whip and disconnect installed for outdoor unit. Pressurized to 342 psi for ten minutes and holding triple evacuated and pumped down to 248 microns and held 10 minutes 1.9 ounces added for charge. Tested for gas leaks set low and high gas pressure and did combustion analysis everything was up to factory standards. Customer was provided with instructions. Tested water at 9 grains hardness. Filter 16x25x1

Near Summerlin Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Upon arrival found water leaking at the top of water heater, 2 gallon expansion tank is leaking, quoted for repair for new expansion tank 4 gallon expansion tank and piping modifications water heater is 9 years old life expectancy is 10 years old would recommended replacing water heater due to age and condition emailed both proposals customer will call office

Near Whitehorse Dr, Honey Brook, PA 19344
Kurt M.

Kurt M.

Found amana a/c installed 5/25/16 low on charge and cycling on and off the low pressure switch outside with pressures of 180/63 with a subcooling of 3.2 . Since the a/c season is over for the year didn’t recomend we add some charge now and leak dye till the system can be back in operation and cycle the leak dye through out the system. We will need to return early spring to add refrigerant and leak dye to further diagnose. Will need to schedule tune appointment at the same time.

Near Cog Hill Dr, Honey Brook, PA 19344
Kurt M.

Kurt M.

Performed precision heat tune up on Weil McLain boiler. Replaced rf1 oil filter. Replaced 1.00 70a nozzle. Vacuumed soot from inside boiler and base of chimney. Performed smoke and combustion test. Recomend starting to think about replacing boiler due to age of system. But boiler is still working at this point. Boiler is lighting pretty hard at times, and told homeowner don’t know how long it’s going to stay working.

Near Horseshoe Pike, Honey Brook, PA 19344
Kurt M.

Kurt M.

Found a very small amount of water in drain pan. Took off relief pipe and found there was water drips down pipe a good indication that the pressure relief on the water heater had blown off. Checked the expansion tank pressure with no water pressure on the tank. Pressure was good. Checked the water pressure while the tank was cold and water pressure was around 85 psi. Plugged back in water heater and checked pressure while heating it got up around 95 psi. At this point there could have been a spike in water pressure from the municipal water. Told homeowner to keep an eye on it and give us a call if the problem would happen again.

Near Summerlin Dr, Honey Brook, PA 19344
Kurt M.

Kurt M.

Performed precision heat tune up on American standard gas furnace. Aprilaire 401 air filter is clean. Blew out condensate drain. Cleaned flame sensor. Checked all electrical conections and components. Checked gas pressure and performed combustion test. Gas furnace is working fine at time of service.

Near Augusta Dr, Honey Brook, PA 19344
Luis T.

Luis T.

Customer was having issues with heat, check propane manifold pressure set low and high to manufacturer specifications, noticed heater would cut out after running and still call for heat, found double trap on heater trap repair trap and test low and high ok heater running. At manufacturer standards ran heater after adjustment and no problems were found

Near Barneston Rd, Honey Brook, PA 19344
Luis T.

Luis T.

Installed new furnace, re connected plenum between coil and furnace and sealed all metal connections. Changed air filter and re connected return boot to furnace. Re ran ac condensate to pump. Re connected venting and furnace drain. Cleaned out condensate pump and tested drains. Re ran all new gas piping from track pipe to unit old was galvanized with union in cabinet.. new 4x4 box with switch and outlet. Wired all electrical connections pump wired to break r on thermostat. Unit was set for 1000 cfms for cooling to match outdoor unit. Thermostat was put into a 2 degree offset.

Near Barneston Rd, Honey Brook, PA 19344