COVID-19 Announcement to Customers

Email Us

Book Now

Call DiBiase

Call 610-873-1244 Book Now Email Us

Paoli PA Heating Air Conditioning Service Repair

DiBiase provides air conditioning, heating and water heater services to the residents of Paoli, PA and the surrounding areas for years. They are a top-rated business who puts your comfort first!!

Read our reviews and find out why your Pennsylvania neighbors consider us to be their nearby heating and air company in Paoli, PA.

Local Reviews
for Paoli, PA

DiBiase Heating and Cooling Company Rated 4.9 out of 5 stars based on 29 customer reviews
Mobile Tools for Contractors and Service Professionals Powered by Nearby Now


Map of Paoli, PA

overall a pleasant experience




Review of DiBiase Heating and Cooling Company


Map of Paoli, PA

Heating Service




Review of DiBiase Heating and Cooling Company


Map of Paoli, PA

Great Servie




Review of DiBiase Heating and Cooling Company

I believe that Joseph did all he could to repair the heating and air conditioning unit I have now so that I would not have to get a new unit.


Map of Paoli, PA

Good Servioce




Review of DiBiase Heating and Cooling Company

He explained why this particular part needed tto be replaced


Map of Paoli, PA

Very professional and good customer service




Review of DiBiase Heating and Cooling Company


Map of Paoli, PA

Extremely satisfied -Chris was great!




Review of DiBiase Heating and Cooling Company


Map of Paoli, PA

Service




Review of DiBiase Heating and Cooling Company


Map of Paoli, PA

Great Service; however could not resolve problem. Will follow up on Monday.




Review of DiBiase Heating and Cooling Company


Map of Paoli, PA

Very good. Nice guy




Review of DiBiase Heating and Cooling Company


Map of Paoli, PA

Service




Review of DiBiase Heating and Cooling Company

Luis was excellent! Explained everything about our “old” unit.


Fast response on a Saturday




Review of DiBiase Heating and Cooling Company


Great service




Review of DiBiase Heating and Cooling Company


Great service.




Review of DiBiase Heating and Cooling Company

Have never had any problems with any of your technicians. Always satisfied with the service performed.


Great service! So glad this company was recommended to us!




Review of DiBiase Heating and Cooling Company

Professional service. Appreciate notice they are on way to house and include picture of technician. Everything explained clearly and options given. Would recommend to anyone!


Service was great. Had no problems.




Review of DiBiase Heating and Cooling Company

Thought price was excellent.


Trusted




Review of DiBiase Heating and Cooling Company


5 star rating




Review of DiBiase Heating and Cooling Company

Great service, prompt and friendly and well knowledgeable 5 star service!


Appreciate your cooperating with PECO's energy assessment




Review of DiBiase Heating and Cooling Company

Your technicians noticed and addressed points overlooked by previous service from another company.


Great service




Review of DiBiase Heating and Cooling Company

Excellent


27Dec




Review of DiBiase Heating and Cooling Company


Fall checkup




Review of DiBiase Heating and Cooling Company


Excellent service




Review of DiBiase Heating and Cooling Company

The technician was knowledgeable and did a great job!


technician was very professional in addition to the great service




Review of DiBiase Heating and Cooling Company


Great service




Review of DiBiase Heating and Cooling Company


Price is excellent. Technician knowledgable and courteous.




Review of DiBiase Heating and Cooling Company

Same as above.


Kurt M.

Kurt M.

Got customer to turn system into a/c mode. Pulled all 410a refrigerant back into outdoor unit. Pulled disconnect and flipped it into the off position so ther is no high voltage power going to outside unit. Cut refrigerant lines at outdoor unit and tapped off with electrical tape. There is now no pressure in the refrigerant lines and customer can disconnect and pull the out of wall cavity.

Near Continental Ln, Paoli, PA 19301
Kurt M.

Kurt M.

Performed heating maintenance, replaced standard air filter, cleaned burners and flame sensor, inspected heat exchanger. Checked voltage, amperage and electrical connections, measured capacitor values. Started gas furnace, measured fuel pressures. Performed combustion test. Checked operation and temperature rise. Joan asked about moving the thermostat. I explained that there are wireless thermostats that can be moved. Joan wants to get the wireless thermostat. Need a 1 heat/1 cool wireless thermostat. 1/18/21. Installed Honeywell wireless thermostat where customer preferred it to be installed. Installed wireless module with 18/5 thermostat wire. Made all electrical conections. Cycled thermostat in both heating and cooling mode. Thermostat is functioning correctly. Showed homeowner how to operate thermostat. System is working fine at time of service.

Near Paoli Pointe Dr, Paoli, PA 19301
Dean M.

Dean M.

Perform Quality Assurance inspection on newly installed gas comfort pack. Checked over system. Everything sealed and no leaks. No gas leaks. System running great at time of QA.

Near Paoli Pointe Dr, Paoli, PA 19301
Kurt M.

Kurt M.

Found gas furnace locked out on high limit. Put duct thermometer in the plenum and found temperature going up above 160 degrees threshold of high limit. Customer mentioned that yesterday they were running the a/c to try to cool down beacause of oven running for cooking. Told homeowner you can not run th a/c when it is cold outside this cause evaporator coil to freeze solid. Put system into fan on and customer may take bottom panel off and use electric heater to un thaw coil, just warned customer about using an electric space heater. Once coil is thawed out can resume normal operation.

Near Paoli Pointe Dr, Paoli, PA 19301
Brian B.

Brian B.

Performed PECO inspection, checked air filter, it’s new. Tested electric back up heaters. Checked voltage, amperage and electrical connections, measured capacitor values. Blew out condensate trap. Tested water safety. Started heat pump, tested defrost cycle. Calculated btu output. Measured refrigerant pressures. Checked operation and temperature rise across coil

Near Weatherstone Dr, Paoli, PA 19301
Kurt M.

Kurt M.

Found when we arrived that system was not running. Went into communication thermostat and did not see any very high energy usage. System is a carrier infinity system. When we went down to the basement took off cover and up near auxiliary heat it felt warm but blower was not running and system was not calling for auxiliary heat. Found that we had an amp draw of about 12 amps and heat in the duct work. Homeowner is going to go back to haily oil and have system repaired.

Near N Valley Rd, Paoli, PA 19301
David B.

David B.

Removed old threw the wall package unit. Installed a new comfort pack threw the wall unit. Reconnected supply and return ductwork. Reinstalled ez trap and wired it in to unit.

Near Paoli Pointe Dr, Paoli, PA 19301
Chris B.

Chris B.

Arrived onsite to perform Precision Heating Tune Up on system. Inspected electrical components on system. Removed Supply Duct from unit to inspect Heat Exchanger. Upon inspection, found multiple areas of Failure on the heat exchanger where it was cracked and split open. Showed Homeowner condition of the Heat Exchanger. Due to age of system, 12 Years, and heat exchanger condition, replacement of the system is needed. Due to the failed heat exchanger, informed customer that it is not safe to operate the system. Turned power off to unit and turned gas valve off with a lockout tag. Did not complete Tune Up due to heat exchanger failure. The office will follow up shortly with a proposal for replacement and availability to schedule to the installation.

Near Paoli Pointe Dr, Paoli, PA 19301
Brian B.

Brian B.

Performed heating maintenance, replaced media air filter with provided filter. Tested electric back up heaters. Checked voltage, amperage and electrical connections, measured capacitor values. Started heat pump, tested defrost cycle. Measured btu output. Checked operation and temperature rise across coil.

Near W Golf Club Ln, Paoli, PA 19301
Chris B.

Chris B.

Service call that the Heat was not working and it may be a power related issue. Upon arrival spoke with homeowner about issue. Found thermostat calling for heat but the system was not running. Inspected unit and found system out on a 3 Flash High Limit Lockout code. Reset unit and tested. Air Supply temperature was exceeding 150 Degrees and causing unit to shut down on high limit safety. This unit has a multi-speed blower motor. Increased Blower Speed for heating to the highest Speed Tap. Put unit in operation and continued to monitor. Allowed system to run for over 15 minutes and Supply Temperature did not exceed 125 Degrees. The ductwork for these homes is undersized and causes the Temperature rise to be higher than normal.

Near Paoli Pointe Dr, Paoli, PA 19301
Chris B.

Chris B.

Returned to site to replace the 4” Flexible Dryer Vent. Removed broken flex of Dryer Vent. Installed new 4” Flexible Aluminum Puncture & Rip Resistant Dryer Vent and sealed connections. Before installed new Vent, vacuumed accessible hard pipes dryer duct. Vacuumed Utility Closet and around HVAC system. Left Quotes for replacement of the system with homeowner to review. Payment for repair paid by Check. Check #: 9817 in the amount of $251.81.

Near Paoli Pointe Dr, Paoli, PA 19301
Chris B.

Chris B.

Performed Precision Heating Tune Up on Through the Wall Gas Furnace. Replaced 16x25x1 Air Filter. Inspected electrical components on unit. Found upon arrival that dryer vent that hangs behind the unit was ripped and lint and dryer exhaust was emptying into the utility closet. Included estimate for the replacement of the Flexible Dryer Vent. Removed Supply Plenum and inspected heat exchanger. Found several rust spots on exterior of Heat Exchanger Tubing. Performed Combustion Test and combustion readings were within rating. Due to the rust on the Heat Exchanger would recommend replacement of the system before any failure of the heat exchanger occurs. Age of unit is about 10 Years Old.

Near Paoli Pointe Dr, Paoli, PA 19301
Kurt M.

Kurt M.

Performed precision heat tune up on Rheem gas furnace. Replaced Aprilaire 413 air filter ( homeowner provided) checked all electrical components and connections. Cleaned flame sensor. Blew out condensate drain and pressure switch tubing. Checked temperature rise. Checked gas pressure. Performed combustion test. Found water heater is around 9 years old recommended replacement of water heater. Provided customer a quote. Gas furnace is working fine at time of inspection.

Near Friendship Dr, Paoli, PA 19301
Brian B.

Brian B.

Performed six month quality check, replaced air filter. Started gas furnace tested limit and safety switches, performed combustion test. Explained thermostat. Cycled air conditioner. Everything is working fine.

Near Paoli Pointe Dr, Paoli, PA 19301
Luis T.

Luis T.

Performed Quality Assurance inspection on a newly installed comfort pack system. Checked over entire system. No air leaks. No gas leaks. Wiring proper and secure. Checked fan speed. It’s set to medium high for heat and high for cooling. System running great at time of QA.

Near Paoli Pointe Dr, Paoli, PA 19301
Brian B.

Brian B.

Checked thermostat, found set for 68 and reading 68. Julia stated that when she changed the temperature setting the room temperature would also change. Checked thermostat setup. Found nothing wrong with the thermostat. I explained that the thermostat is very accurate and just touching the thermostat can change the room temperature. Cycled furnace and checked operation.

Near Paoli Pointe Dr, Paoli, PA 19301
Brian B.

Brian B.

Performed PECO check, checked air filter, found a new filter. Tested electric back up heaters. Blew out condensate trap and drain. Checked voltage, amperage and electrical connections. Started heat pump, calculated btu output getting 35640 at 52 degrees. Checked operation and temperature rise across coil.

Near Hawthorne Pl, Paoli, PA 19301
Luis T.

Luis T.

Removed threw the wall heater. Installed a new comfort pack threw the wall heater and tested unit in all modes. Reconnected drain and installed a new ez trap and wired in to the unit. Reconnected gas piping and adapted as needed. Bubble checked all gas piping.

Near Paoli Pointe Dr, Paoli, PA 19301
Brian B.

Brian B.

Checked no heat complaint, found thermostat set to off. Set to heat, furnace started and ran, after 5 minutes the furnace locked out on limit switch open. Inspected heat exchanger, see what may be a restriction in the second pass, see pictures. Checked limit switch it appears to be in good condition. Cycled furnace I’m getting a 148 degree supply and a 78 degree dt. I recommend replacing the limit switch first and if limit continues to trip a new heat exchanger will be needed.

Near Paoli Pointe Dr, Paoli, PA 19301
Chris B.

Chris B.

Returned to site to get Signed Agreement for upcoming installation and collect Deposit for Installation.

Near Paoli Pointe Dr, Paoli, PA 19301
Paul W.

Paul W.

Drained and removed old boiler. Installed new peerless gas boiler. Installed new circulator pump, isolation valves, shutoff valves, air eliminator, flow check, and new piping to existing heat runs. Installed new t6 thermostat. Ran new gas line and leak checked. Ran high and low volt wiring and installed new switch and receptacle. Tested boiler and performed combustion test, adjusted gas pressure. Purged all air. Boiler working well at time of install.

Near Spruce Ln, Paoli, PA 19301
Joseph D.

Joseph D.

Returned to site to further investigate issue with the Furnace. Put system in heating mode and tested. Verified that system was shutting off on Limit after running for 5-10 Minutes. Removed Return Door Panel and Filter. Reset system and tested airflow with the Return open. Removed Supply Duct and allowed Supply Air to bypass the ductwork and blow into the room. Found unit would stay running with the Supply Duct off, but with only the Return open the unit would continue to shut down in limit. Noted a small increase from .95 Amps on the blower motor to .99 Amps on the Blower Motor with the Supply duct off. Cross referenced this unit with other units in the building and found this unit is sized larger. Other systems are 38,000 BTUs on the Furnace and this unit is 51,000 BTUs on the Furnace. This larger output of the Furnace may be too large for the ductwork. Inspected Indoor Coil and Blower Motor. Found some rust and corrosion on left side of coil. Had called manufacturer previously while

Near Paoli Pointe Dr, Paoli, PA 19301
Chris B.

Chris B.

Service call that the Gas Furnace was not working again. Upon arrival found Indoor Temperature at 73 Degrees and the system was turned off. Turned system on to test operation. System fires up and operates but then will shut down from the Main Limit Switch at the Heat Exchanger. Tested combustion on system and measured gas pressure. Disassembled unit to access the Blower Motor. Tested Amp Draw on blower motor which was within rating. Blower was drawing 1.1 Amps and is rated for 1.4 Amps. Inspected Blower Wheel for debris or obstructions. Removed Supply Ductwork on top of the Unit to inspect the Heat Exchanger. Found no visible damage or failure points in the heat exchanger tubing.

Near Paoli Pointe Dr, Paoli, PA 19301
Chris B.

Chris B.

Service call that the Heat was not running. Upon arrival found indoor temperature at 76 degrees and the system was turned off. Put system in heating mode to test. System began operating with no issues. Measured Air Temperatures on system. Found a Higher Temperatures on the Supply which was nearing the Limit Switch cut off. Increased Blower Fan speed to High Setting and increased blower off delay to 160 seconds to allow more heat dissipate from the unit. Inspected Heat Exchanger and found no blockages or damage. Inspected Air Filter on unit. Checked vents in apartment to ensure they were open and nothing was blocking them. Due to the warm outdoor temperature and the high indoor temperature this could be causing the higher temperature splits and causing the furnace to overheat and shut down on a Safety Limit. Would not run the Heater when the indoor and outdoor temperature is higher.

Near Paoli Pointe Dr, Paoli, PA 19301
Brian B.

Brian B.

Performed heating maintenance, replaced air filter. Checked voltage, amperage and electrical connections, measured capacitor values. Cleaned burners and flame sensor, inspected heat exchanger. Started gas furnace, tested limit and safety switches. Performed combustion test. Checked operation and temperature rise.

Near Paoli Pointe Dr, Paoli, PA 19301