When it comes to your West Brandywine Township, PA’s home heating, cooling and water heater systems, DiBiase Heating & Cooling Company makes sure they’re running at peak efficiency for your improved indoor comfort, convenience and safety.
This is a service promise and a reflection of our core values: integrity, honesty, quality. Read reviews from your neighbors in West Brandywine Township, PA to see how we live up to these values every day, in every way.

Local Reviews
for West Brandywine Township, PA

DiBiase Heating and Cooling Company Rated 5.0 out of 5 stars based on 5 customer reviews


Great Service.




Review of DiBiase Heating and Cooling Company


perfect




Review of DiBiase Heating and Cooling Company

Arrived on time, could not have been more professional, Excellent service. Thank you!


Excellent service




Review of DiBiase Heating and Cooling Company

We have received excellent service from DiBiase Heating and Cooling Company. The administrative staff is friendly and professional and the service technicians are prompt, courteous and knowledgeable. I highly recommend this company to anyone seeking HVAC service.


Great Service




Review of DiBiase Heating and Cooling Company

Excellent service, kept me informed & very professional.


Amazing service




Review of DiBiase Heating and Cooling Company

I called many heating companies to come out and check my unit but DiBiase heating within an hour called me back and got my heat working again. It's only been about an hour since they worked on it but my home is heated again with no problems. Thank you guys again for doing a great job. Definitely 5 star satisfaction rating.


Kurt M.

Kurt M.

Performed precision heat tune up on oil furnace. Aprilaire 401 air filter is ok. Checked all electrical conections and components. Replaced.75x70a nozzle. Replaced rf-1 oil filter. Checked pump screen. Vacuumed out soot inside furnace and at chimney base. Oil furnace is working fine at time of service.

Near Hibernia Rd, West Brandywine Township, PA 19320
Luis T.

Luis T.

Performed precision heat tune up on unico heatpump system. Replaced 14x30x1 air filter. Checked all electrical conections and components. Blew out condensate drain. Checked refrigerant pressures and temperatures at indoor and outdoor units. System is working fine at time of service.

Near Baker Rd, West Brandywine Township, PA 19320
Luis T.

Luis T.

Performed ac check up, on high velocity system attic, check electrical low and high ok replace customer supplied filter 14x30x1 flushed drain ok check outdoor unit 410 pressures check capacitor and contactor ok super heat and sub cooling ok cycle unit ok

Near Baker Rd, West Brandywine Township, PA 19320
Luis T.

Luis T.

Had previously been onsite and found that Indoor Unit flashing a 2 Error Code. After troubleshooting with Technical Support, determined that the Indoor Coil and Room Temperature Thermistors had failed. Manufacturer recommended replacement of the Indoor Unit Control Board. At the time of the service call the second Indoor Unit was operating. Homeowner informed us 24-48 hours later that the second Indoor Unit was flashing a Code also. If the Second Unit is not operating properly it will require additional troubleshooting and diagnostics. 7-12-18 luis replace indoor control P.C. board, coil thermistor and ambient temp thermistor cycle and check split on u it ok supply 52 return 76 other head working ok no issues found at this time

Near Swinehart Rd, West Brandywine Township, PA 19320
Kurt M.

Kurt M.

Found Mitsubishi mini split system has 2 indoor heads connected to one outdoor unit. Found bedroom indoor head working perfectly fine and living room head flashing error code 2 on operation light. Called Mitsubishi tech support case number 443788. Found it to be open thermistor error code. They recommended rempalcing indoor thermisters and indoor control board to solve issue. Distributors are closed at this time will call tomorrow to get availability.

Near Swinehart Rd, West Brandywine Township, PA 19320
Luis T.

Luis T.

Found unit turned on and was running when homeowner turned on at thermostat. She described yesterday when she went outside hearing a humming noise, but nothing running. Pulled out 25/5 capacitor and tested. Found that capacitor was bad. Also found single pole 40 amp contactor was wearing out and was pitted. Recommend replacing both capacitor and contacter. Replaced and checked r22 pressures at 66 degrees were 153/59. System is back up and working fine at time of service.

Near Swinehart Rd, West Brandywine Township, PA 19320
Luis T.

Luis T.

Upon arrival everything worked ok filter #213 needed replaced I saw there was no saftey wired in for the condensate pump or an ez trap recommend replacing and adding eztrap upon further discovery noticed barcteria and mold growing from coil insulation, showed customer and recommended a reme left brochures. Delta t 18 degrees.

Near Audrey Lynn Dr, West Brandywine Township, PA 19320
Luis T.

Luis T.

No heat oil furnace, found clogged nozzle, also electrodes need to get replaced, flat ends, will need new oil filter and strainer both items are very dirty almost clogged, quoted fore above repairs, customer ok, replce nozzle .75x70A new pump strainer, new RF-1 and set of new electrodes, purge oil line and check for leaks at oil filter and strainer ok, adjust air on burner, combustion test and Smoke test ok cycle heater ok check 401 filter ok

Near Hibernia Rd, West Brandywine Township, PA 19320
Chris B.

Chris B.

Performed precision heat tune up on heat pump. Replaced air filter. Verified humidifier operation, and drainage. Verified proper refrigerant temps and pressures. Verified proper electrical and mechanical components. All major components operate properly at time of service.

Near Audrey Lynn Dr, West Brandywine Township, PA 19320
Joseph D.

Joseph D.

We will recover any remaining refrigerant in system. We will flush the system with nitrogen and add acid away neutralizer to system. We will disconnect, and remove compressor and install a new OEM system compressor and complete all connections. We will process the warranty for the new compressor. We will pressure test the system and evacuate the system in accordance with manufacturers specifications. We will charge the unit with new R410A refrigerant and test the system to ensure proper operation. Note: Compressor burnouts can be caused by other issues. We cannot properly test the system with the compressornot functioning. There may be an underlying cause to the failure that will be determined once the compressor is replace. There may be additional charges to get the system functioning after the compressor is replaced. Performed the above quote. System is functioning to standards at this time.

Near Baker Rd, West Brandywine Township, PA 19320
Joseph D.

Joseph D.

We will recover any remaining refrigerant in system. We will flush the system with nitrogen and add acid away neutralizer to system. We will disconnect, and remove compressor and install a new OEM system compressor and complete all connections. We will process the warranty for the new compressor. We will pressure test the system and evacuate the system in accordance with manufacturers specifications. We will charge the unit with new R410A refrigerant and test the system to ensure proper operation. Note: Compressor burnouts can be caused by other issues. We cannot properly test the system with the compressornot functioning. There may be an underlying cause to the failure that will be determined once the compressor is replace. There may be additional charges to get the system functioning after the compressor is replaced. Performed the above quote. System is functioning to standards at this time.

Near Baker Rd, West Brandywine Township, PA 19320
Dan S.

Dan S.

No ac . When I arrived the system was not running. The homeowner said the thermostat had power but no matter what he switched it to the system would not respond. I then checked the indoor system to find no power to the indoor system . I then went to the panel to find the breakers were off to the indoor and outdoor systems . The breakers were not tripped there were completely shut off . I looked at the thermostat and noticed that the thermostat was battery operated so if the system lost power the thermostat would still have power and work . I tested the system off and on numerous of times by power switch by furnace and by thermostat . I checked the outdoor unit low and high voltage readings and wiring. They were fine . The homeowner did tell me that he had a power surge some weeks back . I explained to the homeowner that If the problem persists I would say that the board is intermittent and not calling at times . But from what I see now the system is running to standards with a temperat

Near Ashberry Ln, West Brandywine Township, PA 19320
Joseph D.

Joseph D.

Inspected job site and provided estimate to replace the system compressor under warranty.

Near Baker Rd, West Brandywine Township, PA 19320
Joseph D.

Joseph D.

Found no power to thermostat on arrival. Measured voltage at furnace at 24 v going to thermostat. Jumped wires at thermostat and system started. Installed new T4 thermostat and tested operation. Tested in heating and cooling modes of operation. Measured supply temp at 66 degf and return temp at thermostat reading 84.

Near Ashberry Ln, West Brandywine Township, PA 19320
Nathan P.

Nathan P.

We did install unit. Upon arrival found system operating to specifications. Checked charge 140 low 306 high 3.4 sh 7.9 sc. temperature split 15 degrees. Clean filter. Poured water in pan and tested drainage (all ok). Later customer informs me HORN HEATING AND AIR was out because unit stopped working few weeks ago. They replaced filter and condensate tubing from the pump to sewer. Customer also stated he went down Jiggled the condensate pump ( condensate pump is clean) As of now system is functioning and no water is present.

Near Audrey Lynn Dr, West Brandywine Township, PA 19320
Nathan P.

Nathan P.

Upon arrival found no power to outdoor unit. Reset breaker that was tripped. Compressor tripped Breaker again. Tested and found bad compressor. Also gas leaking from Around compressor terminal connections. Installed by friend 3 yrs ago who worked at sheller. Company will call with pricing and options to repair.

Near Baker Rd, West Brandywine Township, PA 19320
Nathan P.

Nathan P.

Upon arrival found bedroom unit remote that needed to be rest. Tested operation. Running to specifications

Near Swinehart Rd, West Brandywine Township, PA 19320
Joseph D.

Joseph D.

Performed ac precision tune up on system. Found capacitor excessively rusted and showing signs of age and contactor worn on unit. Also found low voltage wire on outdoor unit damaged and sheathing ripped off. Air filter requires replacement.

Near Hibernia Rd, West Brandywine Township, PA 19320
Joseph D.

Joseph D.

Turned on unit and found suction line frosting up. Measured refrigerant charge as 13 psi on suction and 117 on liquid. Unit is very low on charge. Recommend system replacement. Added 4 lbs of R22 refrigerant to system to properly adjust the charge and found indoor blower capacitor blown causing indoor blower to not operate. Replaced blower capacitor and tested blower operation. Rechecked charge.

Near Ashberry Ln, West Brandywine Township, PA 19320
Joseph D.

Joseph D.

Turned system on and observed operation. Found heat pump running in heating mode of operation. Customer indicated thermostat was replaced last winter. Checked thermostat wiring. Rewired and reprogrammed for heat pump. Tested charge on unit. Recommend service plan on equipment and annual maintenance. Recommend indoor coil cleaning and maintenance.

Near Allison Dr, West Brandywine Township, PA 19320
Joseph D.

Joseph D.

* We recovered the refrigerant from the system and disconnected, removed and disposed of the existing unit. * We installed a new Mitsubishi hyper heat unit Model MXZ2C20NAHZ. We installed the new unit on a new pad and level the outdoor unit. * We reconnected all existing linesets and wiring to the unit. * We pressure tested the system and evacuated and charged the system in accordance with manufacturers specifications.

Near Swinehart Rd, West Brandywine Township, PA 19320
Christopher B.

Christopher B.

This is an Upgraded Aprilaire High Efficiency Air Filter. The original housing is bigger because it fit an older style Aprilaire Filter. The Upgrade Kit allows us to use a newer Filter which is held in place by rails on both top and bottom. This upgrade now uses a 213 Filter which is easier to replace than the original. Oh yeah, see how the Filter is Gray?! That means it needs to be changed, a new one is White! This upgrade kit was installed several years ago by a different company.

Near Hibernia Rd, West Brandywine Township, PA 19320
West Brandywine Township, PA - This is an Upgraded Aprilaire High Efficiency Air Filter. The original housing is bigger because it fit an older style Aprilaire Filter. The Upgrade Kit allows us to use a newer Filter which is held in place by rails on both top and bottom. This upgrade now uses a 213 Filter which is easier to replace than the original. Oh yeah, see how the Filter is Gray?! That means it needs to be changed, a new one is White! This upgrade kit was installed several years ago by a different company.
Bryan D.

Bryan D.

Performing a no Ac in coatesville on a 15 year old York system.

Near Ashberry Ln, West Brandywine Township, PA 19320
Bryan D.

Bryan D.

Performing a no Ac in coatesville on a 15 year old York system.

Near Ashberry Ln, West Brandywine Township, PA 19320
Bryan D.

Bryan D.

Performing a no Ac in coatesville on a 15 year old York system.

Near Ashberry Ln, West Brandywine Township, PA 19320