610-873-1244 Book Online Text Us

Chester, PA

Expert HVAC Service and More in Chester, PA

DiBiase Heating and Cooling ComPAny provides a full range of services to keep your home comfortable and efficient year-round in Chester, PA. Whether you need HVAC rePAir, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer rePAirs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling ComPAny is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling ComPAny is a family-owned and operated comPAny that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us aPArt is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in Chester, PA

Rated 5.0 out of 5 stars based on 1 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting a high level of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and efficiency demonstrated by the service team. A dominant theme throughout is the technicians' exceptional communication skills, with reviewers frequently praising how thoroughly issues were explained in clear, understandable terms. The company's customer-focused approach emerges as a standout quality, with multiple mentions of staff going above and beyond expectations, taking extra time to answer questions, and showing genuine care for customer needs. Reviewers repeatedly highlight the knowledgeable and friendly demeanor of the technicians, noting their respectfulness toward property and their ability to provide detailed assessments. The thoroughness of inspections and maintenance visits receives particular acclaim, with customers expressing confidence in the quality of work performed. Many reviews emphasize positive ongoing relationships, indicating strong customer loyalty and satisfaction with repeat service experiences. The sentiment of trust is evident, with customers appreciating honest recommendations and feeling empowered to make informed decisions. Overall, the tone is enthusiastically positive, conveying a sense of relief and satisfaction that the company delivers exceptional, reliable service that exceeds modern expectations for integrity and customer care.

Chester, PA at a glance

DiBiase Heating and Cooling Company has completed 10 jobs in Chester, PA between January 2024 and September 2026.

The one customer review shown here is rated 5.0 out of 5.

The most recent job was on September 28, 2026.

DiBiase Heating and Cooling Company has completed 3 jobs in Chester, PA in the last 12 months. The first job there was in December 2023.

Our Local Reviews by City

Job Locations and Reviews

Upon arrival, the system was already drained. I replaced the condensate return tank for the steam boiler. After filling the system, I discovered a cracked boiler block causing water to dump onto the burners. Additionally, there was a significant leak on the wet return behind the boiler. To prevent further damage, I turned off the power to all components and shut off the water feed to the tank. I promptly contacted management and documented the issues with photos and videos. Unfortunately, no payment was collected as no one was present.
Upon arrival, the system was already drained. I replaced the condensate return tank for the steam boiler. After filling the system, I discovered a cracked boiler block causing water to dump onto the burners. Additionally, there was a significant leak on the wet return behind the boiler. To prevent further damage, I turned off the power to all components and shut off the water feed to the tank. I promptly contacted management and documented the issues with photos and videos. Unfortunately, no payment was collected as no one was present.
Nathan P.
Nathan P. Checked in
Upon arrival, the system was already drained. I replaced the condensate return tank for the steam boiler. After filling the system, I discovered a cracked boiler block causing water to dump onto the burners. Additionally, there was a significant leak on the wet return behind the boiler. To prevent further damage, I turned off the power to all components and shut off the water feed to the tank. I promptly contacted management and documented the issues with photos and videos. Unfortunately, no payment was collected as no one was present.
Chester, PA 19013
Review
Explained what they were going to do and get started ordering parts
Ken - Chester, PA 19013
Joseph D.
Joseph D. Checked in
Reviewed the tank replacement and took measurements on the tank and exit strategies. We will be going through the Billco doors down into the basement area. The tank is 24 in. in diameter, 36 in. long, and the piping connections are: - 1 1/4 in. for the overflow and condensate return - 1/2 in. for the feed water makeup - 1 in. for the boiler supply piping Need to get the tank ordered right away. Kenyon is a plumber and can meet us on site, or he will have his helper meet us when we're doing the project.
Chester, PA 19013


We will replace the thermostat for the church location with a new thermostat to control the boiler operaiton for each particular one.  Price is per thermostat. 1/14/26. Installed new t-4 thermostats , Kenyon cycled on the boiler. Found condensation pump is leaking a ton of water and is constantly trying to feed water in the boiler


We will replace the thermostat for the church location with a new thermostat to control the boiler operaiton for each particular one.  Price is per thermostat. 1/14/26. Installed new t-4 thermostats , Kenyon cycled on the boiler. Found condensation pump is leaking a ton of water and is constantly trying to feed water in the boiler
Kurt M.
Kurt M. Checked in
We will replace the thermostat for the church location with a new thermostat to control the boiler operaiton for each particular one. Price is per thermostat. 1/14/26. Installed new t-4 thermostats , Kenyon cycled on the boiler. Found condensation pump is leaking a ton of water and is constantly trying to feed water in the boiler
Chester, PA 19013
Barry P.
Barry P. Checked in
Went through boiler safeties, pressure tool, both low water cut offs (mechanical and electronic). Also opened the electrical boxes and checked all wiring connections generally All switches were closed. I turned on emergency switch at top of steps and boiler came on. Cycled through and made see the pump relay and low water cut off are functioning properly. Monitored boiler pressure after start up: Ok Informed Kenyon System operating well at this time.
Chester, PA 19013
Kurt M.
Kurt M. Checked in
Found boiler locked out on a 1-1 error code. 1-1 code is low a/c line voltage. Checked voltage feeding into control and it was fluctuating 113-119 v . Found micro switches keeping the boiler off. Just bumped them and everything came on. Adjusted the front cut out switch with Allen key only. Ran boiler for about 40 minutes and condensation pump would drive in whater when level dropped down and water level during run time stayed at about 1/2 way in the sight glass. Showed Kenyon how finicky the switches are. Boiler is working at time of service.
Chester, PA 19013
Nathan P.
Nathan P. Checked in
There were several pipes that froze and broke on the condensate return system. Disconnect unions and remove 2" section of condensate return piping that is leaking. Replace ball valve, check valve, and several nipples that need to be replaced. Reassemble piping, turn boiler back on, and check for other leaks throughout. Note: Piping is old and corroded. Piping will be difficult to take apart. If there are other joints that fail, they will be in addition to fix and will be quoted seperately. Found 2 leaks on the return. Cut pipes out and reconnected. Ran system to ensure our new pipes were not leaking.
Chester, PA 19013
Kurt M.
Kurt M. Checked in
Went downstairs to boiler. Cut sight glass to appropriate length. Installed and opened up valves. No leaks at sight glass. Kenyon said he is going to try to repair black iron leaks. Showed Kenyon how to turn on power switch and reset Honeywell control to start up boiler. Job is completed.
Chester, PA 19013
Kurt M.
Kurt M. Checked in
Fully assessed no heating situation. Found Honeywell burner control locked out on alarm status. Found brand new pilot valve, not opening to ignite to light off boiler. Tested and found that there was gas going to pilot valve and also 120 V present At solenoid. No gas coming out the other side of the valve. Our office to find new replacement valve. Also condensate tank pump is very noisy. Our office to get replacement valve and come back and install..
Chester, PA 19013
Kurt M.
Kurt M. Checked in
The burner control is instantly giving error blink code 4-2: Wiring problem/Internal fault. Another contractor repaired the leaking 1” black iron pipe using silicone gasket and hose clamp. See photos. We traced out wiring and made sure was correct, limit circuit, gas valve. ground etc. Called Honeywell tech support who referred us to a local contact based on Chester zip code. Broudy precision (Tech support guys are Ernie and Don) They told us next step is to have the new control taken in to be tested with their diagnostic tool to determine if the control itself has failed. We contacted Bill Rhoades about the error code and he will try to get control tested and/or replaced under warranty ASAP. Meanhike we will provide estimate to install new control entirely. We took apart low water cut off and cleaned body and float. Needs new gasket. (8 bolt gasket) for MacDonald Miller 150 LWCO 3 of the 4 bolts where float assembly is flanged to the make up water tank snapped. We will be in touch
Chester, PA 19013
Kurt M.
Kurt M. Checked in
Found when I arrived boiler was overfilled with water. Found condensation tank pump continuing to fill boiler. Shut off 1/2” copper line for make up water and shut off power to boiler. Took photos of water make up system and leaking 1” or 1 1/4” black iron pipping that was leaking. Let our office know findings. Will come up with a repair estimate. Called pastor al about findings.
Chester, PA 19013
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next