610-873-1244 Book Online Text Us

West Grove, PA

Expert HVAC Service and More in West Grove, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in West Grove, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in West Grove, PA

Rated 5.0 out of 5 stars based on 3 customer reviews

Customers say: The reviews reflect an overwhelmingly positive sentiment toward the HVAC service provided. Customers consistently express appreciation for technicians who are knowledgeable, professional, and efficient in diagnosing and resolving heating issues. The tone across the collection is predominantly positive, with recurring themes of excellent communication, thorough explanations of technical matters, and prompt service—particularly valued during emergency situations in cold weather. Customers frequently highlight the technicians' ability to clearly explain system operations, maintenance recommendations, and available options. The service is repeatedly characterized as courteous and professional, with many customers noting the technicians' transparency and helpfulness. Customers also appreciate the absence of aggressive upselling and the technicians' dedication to resolving problems completely. Overall, the reviews convey a strong sense of customer satisfaction and trust in the technical expertise and customer service provided.

Our Local Reviews by City

Job Locations and Reviews

Completed QA for Bosch heat pump install.

Checked all aspects of install: ductwork connections Mechanical, wiring, controls.
EZ trap wired were landed on U1 contacts. I moved the, to correct contacts S1. And made custom alert. If EZ trap float switch opens it will display alert: Clogged drain line. Clear trap and drain line, Then call for service. System will stop cooling and heating and run blower if EZ trap opens. 
Aux heat (propane furnace’ lockout is set to 35°F 
Measured temperature rise from heat pump (66-88=22° Good)

Install passes quality assurance inspection. 

I sent the email for the maintenance plan membership for the system.
Completed QA for Bosch heat pump install.

Checked all aspects of install: ductwork connections Mechanical, wiring, controls.
EZ trap wired were landed on U1 contacts. I moved the, to correct contacts S1. And made custom alert. If EZ trap float switch opens it will display alert: Clogged drain line. Clear trap and drain line, Then call for service. System will stop cooling and heating and run blower if EZ trap opens. 
Aux heat (propane furnace’ lockout is set to 35°F 
Measured temperature rise from heat pump (66-88=22° Good)

Install passes quality assurance inspection. 

I sent the email for the maintenance plan membership for the system.
Barry P.
Barry P. Checked in
Completed QA for Bosch heat pump install. Checked all aspects of install: ductwork connections Mechanical, wiring, controls. EZ trap wired were landed on U1 contacts. I moved the, to correct contacts S1. And made custom alert. If EZ trap float switch opens it will display alert: Clogged drain line. Clear trap and drain line, Then call for service. System will stop cooling and heating and run blower if EZ trap opens. Aux heat (propane furnace’ lockout is set to 35°F Measured temperature rise from heat pump (66-88=22° Good) Install passes quality assurance inspection. I sent the email for the maintenance plan membership for the system.
West Grove, PA 19390
On Sunday during snowstorm with lots of wind is when the unit was giving them trouble.
They called a friend who is in HVAC he cleaned the flame sensor and inspected the ignition components. The flame would intermittently cut out on them. 
There is a pressure switch checking for .1” of draft.
It is possible that on Sunday during snowfall and 
 wind The unit was not able to produce the draft. I measured -.26” there with manometer today. 
They recently had the Packard draft motor (1/150 HP) replaced.
Told them to replace the (2) 16x20x1 filters soon. 

Ignitor and flame sensor are in bad shape. Unit is from 2007. 

Left separate estimates to replace ignitor and flame sensor. 

Unit did not cut off and had no issue with trial for ignition when I was here. Temp rise 48/98= 50°
 Itold them to talk to our management about consultation for new system considering age or at least anticipate needing to replace unit soon. 

System operating well at this time. 

Could not do combustion test roof ha
On Sunday during snowstorm with lots of wind is when the unit was giving them trouble.
They called a friend who is in HVAC he cleaned the flame sensor and inspected the ignition components. The flame would intermittently cut out on them. 
There is a pressure switch checking for .1” of draft.
It is possible that on Sunday during snowfall and 
 wind The unit was not able to produce the draft. I measured -.26” there with manometer today. 
They recently had the Packard draft motor (1/150 HP) replaced.
Told them to replace the (2) 16x20x1 filters soon. 

Ignitor and flame sensor are in bad shape. Unit is from 2007. 

Left separate estimates to replace ignitor and flame sensor. 

Unit did not cut off and had no issue with trial for ignition when I was here. Temp rise 48/98= 50°
 Itold them to talk to our management about consultation for new system considering age or at least anticipate needing to replace unit soon. 

System operating well at this time. 

Could not do combustion test roof ha
Barry P.
Barry P. Checked in
On Sunday during snowstorm with lots of wind is when the unit was giving them trouble. They called a friend who is in HVAC he cleaned the flame sensor and inspected the ignition components. The flame would intermittently cut out on them. There is a pressure switch checking for .1” of draft. It is possible that on Sunday during snowfall and wind The unit was not able to produce the draft. I measured -.26” there with manometer today. They recently had the Packard draft motor (1/150 HP) replaced. Told them to replace the (2) 16x20x1 filters soon. Ignitor and flame sensor are in bad shape. Unit is from 2007. Left separate estimates to replace ignitor and flame sensor. Unit did not cut off and had no issue with trial for ignition when I was here. Temp rise 48/98= 50° Itold them to talk to our management about consultation for new system considering age or at least anticipate needing to replace unit soon. System operating well at this time. Could not do combustion test roof ha
West Grove, PA 19390
Review
Barry was great. Friendly, knowledgeable, and very detail oriented.
Jim - West Grove, PA 19390
Completed QA for 100,000 BTU propane furnace /heat pump hybrid.

Inspected all aspects of install: mechanical, wiring, piping, control settings, etc.
Checked manifold propane pressures.
Measured temperature rise
Combustion and draft tests: Pass


Moved MC wire to furnace off of CSST gas piping and clamped to return drop.
The propane line is not bonded anywhere. Would require grounding rod, clamps and appropriate copper wire. Took photo of where gas comes into house under deck. Provided email estimate to bond the propane line with new grounding rod.
Also provided estimate to install 1/2” gas shut off valve for gas drier line.


Install passes QA inspection
Completed QA for 100,000 BTU propane furnace /heat pump hybrid.

Inspected all aspects of install: mechanical, wiring, piping, control settings, etc.
Checked manifold propane pressures.
Measured temperature rise
Combustion and draft tests: Pass


Moved MC wire to furnace off of CSST gas piping and clamped to return drop.
The propane line is not bonded anywhere. Would require grounding rod, clamps and appropriate copper wire. Took photo of where gas comes into house under deck. Provided email estimate to bond the propane line with new grounding rod.
Also provided estimate to install 1/2” gas shut off valve for gas drier line.


Install passes QA inspection
Barry P.
Barry P. Checked in
Completed QA for 100,000 BTU propane furnace /heat pump hybrid. Inspected all aspects of install: mechanical, wiring, piping, control settings, etc. Checked manifold propane pressures. Measured temperature rise Combustion and draft tests: Pass Moved MC wire to furnace off of CSST gas piping and clamped to return drop. The propane line is not bonded anywhere. Would require grounding rod, clamps and appropriate copper wire. Took photo of where gas comes into house under deck. Provided email estimate to bond the propane line with new grounding rod. Also provided estimate to install 1/2” gas shut off valve for gas drier line. Install passes QA inspection
West Grove, PA 19390
Drained domestic water.
Removed failed mixing valve.
Also removed and cleaned and reinstalled Laars flow restrictor screen, 
Installed new mixing valve. Purged hot lines and tested system.
I had Karen go to sink and verify water temperature.

System operating well at this time.
Drained domestic water.
Removed failed mixing valve.
Also removed and cleaned and reinstalled Laars flow restrictor screen, 
Installed new mixing valve. Purged hot lines and tested system.
I had Karen go to sink and verify water temperature.

System operating well at this time.
Barry P.
Barry P. Checked in
Drained domestic water. Removed failed mixing valve. Also removed and cleaned and reinstalled Laars flow restrictor screen, Installed new mixing valve. Purged hot lines and tested system. I had Karen go to sink and verify water temperature. System operating well at this time.
West Grove, PA 19390
Cause of hot water temperature being Luke warm is a failed TACO 3-way mixing valve.
Boiler setting for domestic water is at max 140° as designed with 3-way mixing valve. (Taco 5000-3)
I determined it was failed based on temperature readings of 3 pipes.
Attempted to exercise adjustment and lightly smacked valve with rubber mallet to get it to free up, but to no avail.
We will need to schedule to return and replace TACO 5000-3 3 way mixing valve. Covered under Dibiase warranty. 

Installed AG3000 surge protector for boiler. 
Installed Residio L1 leak detector around boiler and tested you can download an app and link this sensor to the app if desired.
Cause of hot water temperature being Luke warm is a failed TACO 3-way mixing valve.
Boiler setting for domestic water is at max 140° as designed with 3-way mixing valve. (Taco 5000-3)
I determined it was failed based on temperature readings of 3 pipes.
Attempted to exercise adjustment and lightly smacked valve with rubber mallet to get it to free up, but to no avail.
We will need to schedule to return and replace TACO 5000-3 3 way mixing valve. Covered under Dibiase warranty. 

Installed AG3000 surge protector for boiler. 
Installed Residio L1 leak detector around boiler and tested you can download an app and link this sensor to the app if desired.
Barry P.
Barry P. Checked in
Cause of hot water temperature being Luke warm is a failed TACO 3-way mixing valve. Boiler setting for domestic water is at max 140° as designed with 3-way mixing valve. (Taco 5000-3) I determined it was failed based on temperature readings of 3 pipes. Attempted to exercise adjustment and lightly smacked valve with rubber mallet to get it to free up, but to no avail. We will need to schedule to return and replace TACO 5000-3 3 way mixing valve. Covered under Dibiase warranty. Installed AG3000 surge protector for boiler. Installed Residio L1 leak detector around boiler and tested you can download an app and link this sensor to the app if desired.
West Grove, PA 19390

Completed 6 month inspection for propane furnace/Heat pump hybrid system:

Homeowner will replace Aprilaire 413 filter soon. 
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked wiring, controls, electric motors and components; 
Checked manifold gas pressures
Inspected drain and pump. Added treatment tabs to pump. 

Checked heat pump operation and temperatures. 

Discussed and provided email estimate for APCOX whole home air treatment system. UV light life span 3 years. Lifetime warranty on unit. 
Will control biological growth at indoor coil and VOCs.

Also provided estimate for plan membership. 

Combustion, draft and smoke tests: Pass

System operating well at this time.

Completed 6 month inspection for propane furnace/Heat pump hybrid system:

Homeowner will replace Aprilaire 413 filter soon. 
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked wiring, controls, electric motors and components; 
Checked manifold gas pressures
Inspected drain and pump. Added treatment tabs to pump. 

Checked heat pump operation and temperatures. 

Discussed and provided email estimate for APCOX whole home air treatment system. UV light life span 3 years. Lifetime warranty on unit. 
Will control biological growth at indoor coil and VOCs.

Also provided estimate for plan membership. 

Combustion, draft and smoke tests: Pass

System operating well at this time.
Barry P.
Barry P. Checked in
Completed 6 month inspection for propane furnace/Heat pump hybrid system: Homeowner will replace Aprilaire 413 filter soon. Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses Inspected hot surface ignitor and verified resistance with meter Cleaned flame sensor and verified flame rectification circuit Measured temperature rise and static pressure Checked wiring, controls, electric motors and components; Checked manifold gas pressures Inspected drain and pump. Added treatment tabs to pump. Checked heat pump operation and temperatures. Discussed and provided email estimate for APCOX whole home air treatment system. UV light life span 3 years. Lifetime warranty on unit. Will control biological growth at indoor coil and VOCs. Also provided estimate for plan membership. Combustion, draft and smoke tests: Pass System operating well at this time.
West Grove, PA 19390
Completed heat tune up for Laars propane combi boiler.
Inspected heat exchanger and burners. 
Inspected ignition assembly 
Inspected hyrdronic components: air separator , feed valves, expansion tank, circulators. 
Cleared condensate sate rep using cap on bottom and added treatment tabs to condensate pump. Both were in good condition
Checked wiring controls and components. Zone panel: 3 Zones 3 circulators. A surge protector can be installed at 120V feed; would protect controls.

Combustion and draft tests: Pass

System operating well at this time. 

This tune up was covered under the expired gas Heat plan for the equipment.
Left estimate for plan renewal.
Also left estimate for plan renewal+surge protector.
Left estimate for audible water alarm.
Completed heat tune up for Laars propane combi boiler.
Inspected heat exchanger and burners. 
Inspected ignition assembly 
Inspected hyrdronic components: air separator , feed valves, expansion tank, circulators. 
Cleared condensate sate rep using cap on bottom and added treatment tabs to condensate pump. Both were in good condition
Checked wiring controls and components. Zone panel: 3 Zones 3 circulators. A surge protector can be installed at 120V feed; would protect controls.

Combustion and draft tests: Pass

System operating well at this time. 

This tune up was covered under the expired gas Heat plan for the equipment.
Left estimate for plan renewal.
Also left estimate for plan renewal+surge protector.
Left estimate for audible water alarm.
Barry P.
Barry P. Checked in
Completed heat tune up for Laars propane combi boiler. Inspected heat exchanger and burners. Inspected ignition assembly Inspected hyrdronic components: air separator , feed valves, expansion tank, circulators. Cleared condensate sate rep using cap on bottom and added treatment tabs to condensate pump. Both were in good condition Checked wiring controls and components. Zone panel: 3 Zones 3 circulators. A surge protector can be installed at 120V feed; would protect controls. Combustion and draft tests: Pass System operating well at this time. This tune up was covered under the expired gas Heat plan for the equipment. Left estimate for plan renewal. Also left estimate for plan renewal+surge protector. Left estimate for audible water alarm.
West Grove, PA 19390
Estimate
Estimate
Diilon M.
Diilon M. Checked in
Estimate
West Grove, PA 19390
Estimate for ductless
Estimate for ductless
Tony F.
Tony F. Checked in
Estimate for ductless
West Grove, PA 19390
Estimate
Estimate
Diilon M.
Diilon M. Checked in
Estimate
West Grove, PA 19390
Review
Thank you to Dan R. for getting our heat up and running! He explained everything and was very polite. The office was kind on the phone 10/10, and had Dan come out fast!
Karen Adams - Burke (DrBlue83) - West Grove, PA 19390
Response from DiBiase Heating and Cooling Company:

Hi Karen! We appreciate your kind words! We're glad Dan got your heat up and running and that he took the time to explain everything. Our team strives to provide quick and friendly service, so it’s great to hear we hit the mark. Thanks for choosing us!

Review
Another great experience from DiBiase Heating and Cooling. Nathan was courteous and efficient in getting my heater work complete. I have been using DiBiase for several years now and they never disappoint.
Dusty McKeown - West Grove, PA 19390
Response from DiBiase Heating and Cooling Company:

Hello Dusty! Thank you for your continued trust in DiBiase Heating and Cooling! We're thrilled to hear that Nathan provided courteous and efficient service for your heater. It's always a pleasure to serve you, and we appreciate your loyalty over the years. We look forward to maintaining our high standards in the future!

Review
Barry was very thorough and really took his time to check out all the pieces that might have something wrong. I was very impressed with his communication and thoroughness. Great experience with a service provider!
Nicole - West Grove, PA 19390
Review
Professional and thorough analysis of my house. Time was taken to answer all of my questions.
Daniel - West Grove, PA 19390
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.