610-873-1244 Book Online Text Us

West Grove, PA

Expert HVAC Service and More in West Grove, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in West Grove, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in West Grove, PA

Rated 5.0 out of 5 stars based on 2 customer reviews

Customers say: The reviews exhibit a positive overall sentiment, with recurring positive themes and sentiments. The majority of reviews express satisfaction with the services provided, highlighting the expertise, professionalism, and courtesy of the technicians. Customers appreciate the prompt and efficient service, with many mentioning the technicians' ability to diagnose and resolve issues quickly. Positive feedback is also directed towards the company's customer service, with many praising the helpfulness and efficiency of the office staff. Customers also mention the quality of the work and the professionalism of the technicians, indicating a high level of satisfaction with the services provided. Additionally, there are mentions of the technicians' knowledge and expertise, with customers expressing confidence in their ability to handle various HVAC-related issues. Overall, the reviews suggest a positive experience with the company, with customers expressing satisfaction with the services provided and the professionalism of the technicians.

Job Locations and Reviews

Drained domestic water.
Removed failed mixing valve.
Also removed and cleaned and reinstalled Laars flow restrictor screen, 
Installed new mixing valve. Purged hot lines and tested system.
I had Karen go to sink and verify water temperature.

System operating well at this time.
Drained domestic water.
Removed failed mixing valve.
Also removed and cleaned and reinstalled Laars flow restrictor screen, 
Installed new mixing valve. Purged hot lines and tested system.
I had Karen go to sink and verify water temperature.

System operating well at this time.
Barry P.
Barry P. Checked in
Drained domestic water. Removed failed mixing valve. Also removed and cleaned and reinstalled Laars flow restrictor screen, Installed new mixing valve. Purged hot lines and tested system. I had Karen go to sink and verify water temperature. System operating well at this time.
West Grove, PA 19390
Cause of hot water temperature being Luke warm is a failed TACO 3-way mixing valve.
Boiler setting for domestic water is at max 140° as designed with 3-way mixing valve. (Taco 5000-3)
I determined it was failed based on temperature readings of 3 pipes.
Attempted to exercise adjustment and lightly smacked valve with rubber mallet to get it to free up, but to no avail.
We will need to schedule to return and replace TACO 5000-3 3 way mixing valve. Covered under Dibiase warranty. 

Installed AG3000 surge protector for boiler. 
Installed Residio L1 leak detector around boiler and tested you can download an app and link this sensor to the app if desired.
Cause of hot water temperature being Luke warm is a failed TACO 3-way mixing valve.
Boiler setting for domestic water is at max 140° as designed with 3-way mixing valve. (Taco 5000-3)
I determined it was failed based on temperature readings of 3 pipes.
Attempted to exercise adjustment and lightly smacked valve with rubber mallet to get it to free up, but to no avail.
We will need to schedule to return and replace TACO 5000-3 3 way mixing valve. Covered under Dibiase warranty. 

Installed AG3000 surge protector for boiler. 
Installed Residio L1 leak detector around boiler and tested you can download an app and link this sensor to the app if desired.
Barry P.
Barry P. Checked in
Cause of hot water temperature being Luke warm is a failed TACO 3-way mixing valve. Boiler setting for domestic water is at max 140° as designed with 3-way mixing valve. (Taco 5000-3) I determined it was failed based on temperature readings of 3 pipes. Attempted to exercise adjustment and lightly smacked valve with rubber mallet to get it to free up, but to no avail. We will need to schedule to return and replace TACO 5000-3 3 way mixing valve. Covered under Dibiase warranty. Installed AG3000 surge protector for boiler. Installed Residio L1 leak detector around boiler and tested you can download an app and link this sensor to the app if desired.
West Grove, PA 19390

Completed 6 month inspection for propane furnace/Heat pump hybrid system:

Homeowner will replace Aprilaire 413 filter soon. 
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked wiring, controls, electric motors and components; 
Checked manifold gas pressures
Inspected drain and pump. Added treatment tabs to pump. 

Checked heat pump operation and temperatures. 

Discussed and provided email estimate for APCOX whole home air treatment system. UV light life span 3 years. Lifetime warranty on unit. 
Will control biological growth at indoor coil and VOCs.

Also provided estimate for plan membership. 

Combustion, draft and smoke tests: Pass

System operating well at this time.

Completed 6 month inspection for propane furnace/Heat pump hybrid system:

Homeowner will replace Aprilaire 413 filter soon. 
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked wiring, controls, electric motors and components; 
Checked manifold gas pressures
Inspected drain and pump. Added treatment tabs to pump. 

Checked heat pump operation and temperatures. 

Discussed and provided email estimate for APCOX whole home air treatment system. UV light life span 3 years. Lifetime warranty on unit. 
Will control biological growth at indoor coil and VOCs.

Also provided estimate for plan membership. 

Combustion, draft and smoke tests: Pass

System operating well at this time.
Barry P.
Barry P. Checked in
Completed 6 month inspection for propane furnace/Heat pump hybrid system: Homeowner will replace Aprilaire 413 filter soon. Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses Inspected hot surface ignitor and verified resistance with meter Cleaned flame sensor and verified flame rectification circuit Measured temperature rise and static pressure Checked wiring, controls, electric motors and components; Checked manifold gas pressures Inspected drain and pump. Added treatment tabs to pump. Checked heat pump operation and temperatures. Discussed and provided email estimate for APCOX whole home air treatment system. UV light life span 3 years. Lifetime warranty on unit. Will control biological growth at indoor coil and VOCs. Also provided estimate for plan membership. Combustion, draft and smoke tests: Pass System operating well at this time.
West Grove, PA 19390
Completed heat tune up for Laars propane combi boiler.
Inspected heat exchanger and burners. 
Inspected ignition assembly 
Inspected hyrdronic components: air separator , feed valves, expansion tank, circulators. 
Cleared condensate sate rep using cap on bottom and added treatment tabs to condensate pump. Both were in good condition
Checked wiring controls and components. Zone panel: 3 Zones 3 circulators. A surge protector can be installed at 120V feed; would protect controls.

Combustion and draft tests: Pass

System operating well at this time. 

This tune up was covered under the expired gas Heat plan for the equipment.
Left estimate for plan renewal.
Also left estimate for plan renewal+surge protector.
Left estimate for audible water alarm.
Completed heat tune up for Laars propane combi boiler.
Inspected heat exchanger and burners. 
Inspected ignition assembly 
Inspected hyrdronic components: air separator , feed valves, expansion tank, circulators. 
Cleared condensate sate rep using cap on bottom and added treatment tabs to condensate pump. Both were in good condition
Checked wiring controls and components. Zone panel: 3 Zones 3 circulators. A surge protector can be installed at 120V feed; would protect controls.

Combustion and draft tests: Pass

System operating well at this time. 

This tune up was covered under the expired gas Heat plan for the equipment.
Left estimate for plan renewal.
Also left estimate for plan renewal+surge protector.
Left estimate for audible water alarm.
Barry P.
Barry P. Checked in
Completed heat tune up for Laars propane combi boiler. Inspected heat exchanger and burners. Inspected ignition assembly Inspected hyrdronic components: air separator , feed valves, expansion tank, circulators. Cleared condensate sate rep using cap on bottom and added treatment tabs to condensate pump. Both were in good condition Checked wiring controls and components. Zone panel: 3 Zones 3 circulators. A surge protector can be installed at 120V feed; would protect controls. Combustion and draft tests: Pass System operating well at this time. This tune up was covered under the expired gas Heat plan for the equipment. Left estimate for plan renewal. Also left estimate for plan renewal+surge protector. Left estimate for audible water alarm.
West Grove, PA 19390
Estimate
Estimate
Diilon M.
Diilon M. Checked in
Estimate
West Grove, PA 19390
Estimate for ductless
Estimate for ductless
Tony F.
Tony F. Checked in
Estimate for ductless
West Grove, PA 19390
Estimate
Estimate
Diilon M.
Diilon M. Checked in
Estimate
West Grove, PA 19390
Completed heat tune up for natural gas boiler. Dates to 1998 There are radiators and cast iron baseboard with bleeders. 

 There are (2) zone valves one is main house the other is sunroom but the baseboards or radiators were cut out of the sunroom at one point. A Carrier Minisplit is installed in sunroom. The minisplit split leaked water inside head. I have looked at this minisplit in the past (they are my neighbors) and the tubing they used for the drain is very brittle and needs to be replaced. 

Cleaned heat exchanger and burners (12) 
Inspected flue pipe and chimney. There is a chimney liner. In good condition 
Standing pilot gas valve ok 
Inspected hydronic components: expansion tank, feed valve, pressure relief valve. The auto air vent is failed. Left estimate to replace this. This will involve isolating boiler then purging after replacing vent, Better to do when boiler temperature is colder in off season.
Monitored boiler temperature and pressure.
Inspected wiring, controls, ele
Completed heat tune up for natural gas boiler. Dates to 1998 There are radiators and cast iron baseboard with bleeders. 

 There are (2) zone valves one is main house the other is sunroom but the baseboards or radiators were cut out of the sunroom at one point. A Carrier Minisplit is installed in sunroom. The minisplit split leaked water inside head. I have looked at this minisplit in the past (they are my neighbors) and the tubing they used for the drain is very brittle and needs to be replaced. 

Cleaned heat exchanger and burners (12) 
Inspected flue pipe and chimney. There is a chimney liner. In good condition 
Standing pilot gas valve ok 
Inspected hydronic components: expansion tank, feed valve, pressure relief valve. The auto air vent is failed. Left estimate to replace this. This will involve isolating boiler then purging after replacing vent, Better to do when boiler temperature is colder in off season.
Monitored boiler temperature and pressure.
Inspected wiring, controls, ele
Barry P.
Barry P. Checked in
Completed heat tune up for natural gas boiler. Dates to 1998 There are radiators and cast iron baseboard with bleeders. There are (2) zone valves one is main house the other is sunroom but the baseboards or radiators were cut out of the sunroom at one point. A Carrier Minisplit is installed in sunroom. The minisplit split leaked water inside head. I have looked at this minisplit in the past (they are my neighbors) and the tubing they used for the drain is very brittle and needs to be replaced. Cleaned heat exchanger and burners (12) Inspected flue pipe and chimney. There is a chimney liner. In good condition Standing pilot gas valve ok Inspected hydronic components: expansion tank, feed valve, pressure relief valve. The auto air vent is failed. Left estimate to replace this. This will involve isolating boiler then purging after replacing vent, Better to do when boiler temperature is colder in off season. Monitored boiler temperature and pressure. Inspected wiring, controls, ele
West Grove, PA 19390
Full assessed 14 year old Weil McLain oil boiler. Found sprirovent corroded and not working. Found 1/2 auto fill over filling boiler. Provided solutions to repair the boiler. Also to replace the boiler as a ball park would be about $10,000 to 17,000. Set over all info. Performed combustion test. They will let us know there decision.
Full assessed 14 year old Weil McLain oil boiler. Found sprirovent corroded and not working. Found 1/2 auto fill over filling boiler. Provided solutions to repair the boiler. Also to replace the boiler as a ball park would be about $10,000 to 17,000. Set over all info. Performed combustion test. They will let us know there decision.
Kurt  M.
Kurt M. Checked in
Full assessed 14 year old Weil McLain oil boiler. Found sprirovent corroded and not working. Found 1/2 auto fill over filling boiler. Provided solutions to repair the boiler. Also to replace the boiler as a ball park would be about $10,000 to 17,000. Set over all info. Performed combustion test. They will let us know there decision.
West Grove, PA 19390
Reviewed home to see what the best options are for furnace replacement and or adding ac.  Returns on first floor only.  Load calc is required and it may be best to insulate the home at the same time.
Reviewed home to see what the best options are for furnace replacement and or adding ac.  Returns on first floor only.  Load calc is required and it may be best to insulate the home at the same time.
Joseph D.
Joseph D. Checked in
Reviewed home to see what the best options are for furnace replacement and or adding ac. Returns on first floor only. Load calc is required and it may be best to insulate the home at the same time.
West Grove, PA 19390
Review
Thank you to Dan R. for getting our heat up and running! He explained everything and was very polite. The office was kind on the phone 10/10, and had Dan come out fast!
Karen Adams - Burke (DrBlue83) - West Grove, PA 19390
Response from DiBiase Heating and Cooling Company:

Hi Karen! We appreciate your kind words! We're glad Dan got your heat up and running and that he took the time to explain everything. Our team strives to provide quick and friendly service, so it’s great to hear we hit the mark. Thanks for choosing us!

Review
Another great experience from DiBiase Heating and Cooling. Nathan was courteous and efficient in getting my heater work complete. I have been using DiBiase for several years now and they never disappoint.
Dusty McKeown - West Grove, PA 19390
Response from DiBiase Heating and Cooling Company:

Hello Dusty! Thank you for your continued trust in DiBiase Heating and Cooling! We're thrilled to hear that Nathan provided courteous and efficient service for your heater. It's always a pleasure to serve you, and we appreciate your loyalty over the years. We look forward to maintaining our high standards in the future!

Review
Barry was very thorough and really took his time to check out all the pieces that might have something wrong. I was very impressed with his communication and thoroughness. Great experience with a service provider!
Nicole - West Grove, PA 19390
Review
Professional and thorough analysis of my house. Time was taken to answer all of my questions.
Daniel - West Grove, PA 19390
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next