610-873-1244 Book Online Text Us

Honey Brook, PA

Expert HVAC Service and More in Honey Brook, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Honey Brook, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in Honey Brook, PA

Rated 5.0 out of 5 stars based on 43 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently express gratitude for professional, knowledgeable, and courteous technicians who demonstrate expertise in diagnosing and resolving HVAC issues efficiently. A recurring theme is the technicians' ability to clearly explain problems and solutions, making customers feel informed and comfortable throughout the service process. Many reviewers emphasize the thoroughness and attention to detail displayed during installations, repairs, and routine maintenance, with several noting how technicians go above and beyond expectations. The prompt response times, particularly for emergency calls, receive frequent praise, as does the professionalism and respectful demeanor of service personnel. Customers repeatedly express confidence in the quality of work performed and indicate strong willingness to recommend the company to others. The positive tone extends to appreciation for warranty reminders and cost-saving suggestions that demonstrate customer-focused service. Overall, the reviews convey a sense of relief, satisfaction, and trust in the company's ability to deliver reliable, high-quality HVAC services with exceptional customer care.

Our Local Reviews by City

Job Locations and Reviews

Estimate
Estimate
Tony F.
Tony F. Checked in
Estimate
Honey Brook, PA 19344
Luis 7-6-26
Talk to customer upon arrival he described no cooling situation Saturday midday, customer lost power Friday night. He reset the unit Saturday afternoon and ever since unit has been running. Test system operation indoor outdoor I didn’t see any error codes at the indoor or outdoor unit system is working properly at the time of visit. I did explain to customer. It’s a two-stage communication system sometimes when system lose power. Computers don’t react right away  by resetting breakers It automatically resets the unit and start working again.
Luis 7-6-26
Talk to customer upon arrival he described no cooling situation Saturday midday, customer lost power Friday night. He reset the unit Saturday afternoon and ever since unit has been running. Test system operation indoor outdoor I didn’t see any error codes at the indoor or outdoor unit system is working properly at the time of visit. I did explain to customer. It’s a two-stage communication system sometimes when system lose power. Computers don’t react right away  by resetting breakers It automatically resets the unit and start working again.
Luis T.
Luis T. Checked in
Luis 7-6-26 Talk to customer upon arrival he described no cooling situation Saturday midday, customer lost power Friday night. He reset the unit Saturday afternoon and ever since unit has been running. Test system operation indoor outdoor I didn’t see any error codes at the indoor or outdoor unit system is working properly at the time of visit. I did explain to customer. It’s a two-stage communication system sometimes when system lose power. Computers don’t react right away by resetting breakers It automatically resets the unit and start working again.
Honey Brook, PA 19344
System not cooling.
When I arrived was 78° in living room where thermostat is.
Homeowner mentioned and I can confirm that the foyer and dining room in the front of the house are comfortable but where thermo is “living room” it gets as high as 80°

Went to indoor equipment and found 20° temperature delta. Fan speed 1050 CFM. We have already experimented by setting fan speed to 1200 and it made this problem worse. See history. 

I found (2) branch ducts for the area that remains hot closed. They are labeled “ kitchen” and  “living room”, the duct labeled “powder room” was also closed but we want to keep that one closed. 
This was more than likely done to try to force more air to the second floor. 

Zoning options or adding a (2) head Minisplit should be considered. 

After opening the dampers labeled kitchen and living room temperature did drop on the living room 1°.

Subcooling matches target 10°

System operating well at this time.
System not cooling.
When I arrived was 78° in living room where thermostat is.
Homeowner mentioned and I can confirm that the foyer and dining room in the front of the house are comfortable but where thermo is “living room” it gets as high as 80°

Went to indoor equipment and found 20° temperature delta. Fan speed 1050 CFM. We have already experimented by setting fan speed to 1200 and it made this problem worse. See history. 

I found (2) branch ducts for the area that remains hot closed. They are labeled “ kitchen” and  “living room”, the duct labeled “powder room” was also closed but we want to keep that one closed. 
This was more than likely done to try to force more air to the second floor. 

Zoning options or adding a (2) head Minisplit should be considered. 

After opening the dampers labeled kitchen and living room temperature did drop on the living room 1°.

Subcooling matches target 10°

System operating well at this time.
Barry P.
Barry P. Checked in
System not cooling. When I arrived was 78° in living room where thermostat is. Homeowner mentioned and I can confirm that the foyer and dining room in the front of the house are comfortable but where thermo is “living room” it gets as high as 80° Went to indoor equipment and found 20° temperature delta. Fan speed 1050 CFM. We have already experimented by setting fan speed to 1200 and it made this problem worse. See history. I found (2) branch ducts for the area that remains hot closed. They are labeled “ kitchen” and “living room”, the duct labeled “powder room” was also closed but we want to keep that one closed. This was more than likely done to try to force more air to the second floor. Zoning options or adding a (2) head Minisplit should be considered. After opening the dampers labeled kitchen and living room temperature did drop on the living room 1°. Subcooling matches target 10° System operating well at this time.
Honey Brook, PA 19344
No cooling.
Homeowner described indoor equipment running but no operation from outdoor unit.
Found failed dual capacitor at outdoor unit. Homeowner agreed to replace capacitor. 
Condenser fan motor originally did not start because it was off on internal overload. Once motor came back to temperature it reset closed on internal overload.
Refrigerant pressures good 10° Subcooling
Temperature split 86-65=21° Good

As a reminder the water heater expansion tank is failed. Prof email estimate as well as estimate for new water heater. 

System operating well at this time. Was installed December 2014. 10 years old. Average lifespan of forced air HVAC equipment is 10-12 years, would strongly consider planning to replace system. Consultations for new systems are free from Dibiase.
No cooling.
Homeowner described indoor equipment running but no operation from outdoor unit.
Found failed dual capacitor at outdoor unit. Homeowner agreed to replace capacitor. 
Condenser fan motor originally did not start because it was off on internal overload. Once motor came back to temperature it reset closed on internal overload.
Refrigerant pressures good 10° Subcooling
Temperature split 86-65=21° Good

As a reminder the water heater expansion tank is failed. Prof email estimate as well as estimate for new water heater. 

System operating well at this time. Was installed December 2014. 10 years old. Average lifespan of forced air HVAC equipment is 10-12 years, would strongly consider planning to replace system. Consultations for new systems are free from Dibiase.
Barry P.
Barry P. Checked in
No cooling. Homeowner described indoor equipment running but no operation from outdoor unit. Found failed dual capacitor at outdoor unit. Homeowner agreed to replace capacitor. Condenser fan motor originally did not start because it was off on internal overload. Once motor came back to temperature it reset closed on internal overload. Refrigerant pressures good 10° Subcooling Temperature split 86-65=21° Good As a reminder the water heater expansion tank is failed. Prof email estimate as well as estimate for new water heater. System operating well at this time. Was installed December 2014. 10 years old. Average lifespan of forced air HVAC equipment is 10-12 years, would strongly consider planning to replace system. Consultations for new systems are free from Dibiase.
Honey Brook, PA 19344
Luis 7-3-26
Customer called in for water leak. Found condensation pump not working at all times. Provided estimate to replace pump and vinyl customer approved repairs. Install new pump and vinyl test pump operation ok. I would recommend getting system inspected there could be some issues with ac system.
Luis 7-3-26
Customer called in for water leak. Found condensation pump not working at all times. Provided estimate to replace pump and vinyl customer approved repairs. Install new pump and vinyl test pump operation ok. I would recommend getting system inspected there could be some issues with ac system.
Luis T.
Luis T. Checked in
Luis 7-3-26 Customer called in for water leak. Found condensation pump not working at all times. Provided estimate to replace pump and vinyl customer approved repairs. Install new pump and vinyl test pump operation ok. I would recommend getting system inspected there could be some issues with ac system.
Honey Brook, PA 19344
Review
Dan, arrived in this sweltering heat and went straight to work servicing the exterior unit, working his way through ensuring the entire unit is working properly. The conformation that everything is in great working condition is a relief.
Alice - Honey Brook, PA 19344
7/2/26 Dan 

I arrived to the customers home to service her 12 yr old trane a/c system.  . I checked the wiring connections and the voltages . I checked and replaced the indoor air filter , filter size is a 16x20x1.  I Inspected the indoor coil and tested the primary drain pan with water and flushed the drain line and cleared. I Took indoor temp splits at the return and the supply  and checked the blower motor condition and operation. I looked at the outdoor unit wiring connections and voltages . I inspected  the outdoor components and checked my unit pressures by using super heat sub cool method.  The system is currently operational but past normal life expectancy. Replacement of system is recommended in the near future.
7/2/26 Dan 

I arrived to the customers home to service her 12 yr old trane a/c system.  . I checked the wiring connections and the voltages . I checked and replaced the indoor air filter , filter size is a 16x20x1.  I Inspected the indoor coil and tested the primary drain pan with water and flushed the drain line and cleared. I Took indoor temp splits at the return and the supply  and checked the blower motor condition and operation. I looked at the outdoor unit wiring connections and voltages . I inspected  the outdoor components and checked my unit pressures by using super heat sub cool method.  The system is currently operational but past normal life expectancy. Replacement of system is recommended in the near future.
Daniel R.
Daniel R. Checked in
7/2/26 Dan I arrived to the customers home to service her 12 yr old trane a/c system. . I checked the wiring connections and the voltages . I checked and replaced the indoor air filter , filter size is a 16x20x1. I Inspected the indoor coil and tested the primary drain pan with water and flushed the drain line and cleared. I Took indoor temp splits at the return and the supply and checked the blower motor condition and operation. I looked at the outdoor unit wiring connections and voltages . I inspected the outdoor components and checked my unit pressures by using super heat sub cool method. The system is currently operational but past normal life expectancy. Replacement of system is recommended in the near future.
Honey Brook, PA 19344
Added 1 bag of “Solar Salt” brand salt to the brine tank of new water softener system. Homeowner has 1 bag remaining. Informed homeowner she will order more.

Gas furnace/AC installed 2017 by Dibiase 9 years old 

Completed AC tune up for 4 Ton Amana AC system

Aprilaire 413 filter ok. Provided email estimate to replace for next tune up. Homeowner may decide to buy them herself.
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; offered surge protector for outdoor equipment circuit, the indoor blower motor has surge protector. Homeowner agreed. Completed work today. Both circuits of the HVAC system now have surge protection. 
Measured temperature split and static pressure 
Inspected drains; cleared EZ trap,
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. 

Closed bypass humidifier damper and set humidistat to OFF for summer (cooling) season. This is all that is needed for humidifi
Added 1 bag of “Solar Salt” brand salt to the brine tank of new water softener system. Homeowner has 1 bag remaining. Informed homeowner she will order more.

Gas furnace/AC installed 2017 by Dibiase 9 years old 

Completed AC tune up for 4 Ton Amana AC system

Aprilaire 413 filter ok. Provided email estimate to replace for next tune up. Homeowner may decide to buy them herself.
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; offered surge protector for outdoor equipment circuit, the indoor blower motor has surge protector. Homeowner agreed. Completed work today. Both circuits of the HVAC system now have surge protection. 
Measured temperature split and static pressure 
Inspected drains; cleared EZ trap,
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. 

Closed bypass humidifier damper and set humidistat to OFF for summer (cooling) season. This is all that is needed for humidifi
Barry P.
Barry P. Checked in
Added 1 bag of “Solar Salt” brand salt to the brine tank of new water softener system. Homeowner has 1 bag remaining. Informed homeowner she will order more. Gas furnace/AC installed 2017 by Dibiase 9 years old Completed AC tune up for 4 Ton Amana AC system Aprilaire 413 filter ok. Provided email estimate to replace for next tune up. Homeowner may decide to buy them herself. Indoor and outdoor coils in good condition Inspected wiring, controls, electric motors and components; offered surge protector for outdoor equipment circuit, the indoor blower motor has surge protector. Homeowner agreed. Completed work today. Both circuits of the HVAC system now have surge protection. Measured temperature split and static pressure Inspected drains; cleared EZ trap, Checked integrity of compressor motor (mega ohm test) Assessed refrigerant charge checked pressures. Closed bypass humidifier damper and set humidistat to OFF for summer (cooling) season. This is all that is needed for humidifi
Honey Brook, PA 19344
Completed AC tune up for 3 Ton Amana heat pump system.
System was installed by Dibiase 2/22/19

Replaced 20x20x1 filter
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; equipment has surge protection
Measured temperature split and static pressure 
Inspected drains; cleared EZ trap, cleaned and tested condensate pump. 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. Good

AC system operating well at this time.
Completed AC tune up for 3 Ton Amana heat pump system.
System was installed by Dibiase 2/22/19

Replaced 20x20x1 filter
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; equipment has surge protection
Measured temperature split and static pressure 
Inspected drains; cleared EZ trap, cleaned and tested condensate pump. 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. Good

AC system operating well at this time.
Barry P.
Barry P. Checked in
Completed AC tune up for 3 Ton Amana heat pump system. System was installed by Dibiase 2/22/19 Replaced 20x20x1 filter Indoor and outdoor coils in good condition Inspected wiring, controls, electric motors and components; equipment has surge protection Measured temperature split and static pressure Inspected drains; cleared EZ trap, cleaned and tested condensate pump. Checked integrity of compressor motor (mega ohm test) Assessed refrigerant charge checked pressures. Good AC system operating well at this time.
Honey Brook, PA 19344
Installed 5-2-1 hard start kit at outdoor unit for main house system. Tested afterwards. 

Completed AC tune up for Main house system. 
4Ton Heat pump hybrid system installed 6/7/19 7 years old.

Aprilaire 213 filter recently replaced by homeowner 
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimates for surge protector for indoor blower motor. The outdoor unit has surge protection, 
Measured temperature split (22°) and static pressure 
Inspected drains; clears EZ trap, tested pump; added treatment tabs to drain pan. Recommend wet switch: water safety device that will shut equipment down if water is detected on floor near equipment. Provided estimate
 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. Good

AC system operating well at this time. Need to decide whether they want to be billed for 1 time tune up ($89) or for plan membership( $189) recommend plan membership
Installed 5-2-1 hard start kit at outdoor unit for main house system. Tested afterwards. 

Completed AC tune up for Main house system. 
4Ton Heat pump hybrid system installed 6/7/19 7 years old.

Aprilaire 213 filter recently replaced by homeowner 
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimates for surge protector for indoor blower motor. The outdoor unit has surge protection, 
Measured temperature split (22°) and static pressure 
Inspected drains; clears EZ trap, tested pump; added treatment tabs to drain pan. Recommend wet switch: water safety device that will shut equipment down if water is detected on floor near equipment. Provided estimate
 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. Good

AC system operating well at this time. Need to decide whether they want to be billed for 1 time tune up ($89) or for plan membership( $189) recommend plan membership
Barry P.
Barry P. Checked in
Installed 5-2-1 hard start kit at outdoor unit for main house system. Tested afterwards. Completed AC tune up for Main house system. 4Ton Heat pump hybrid system installed 6/7/19 7 years old. Aprilaire 213 filter recently replaced by homeowner Indoor and outdoor coils in good condition Inspected wiring, controls, electric motors and components; left estimates for surge protector for indoor blower motor. The outdoor unit has surge protection, Measured temperature split (22°) and static pressure Inspected drains; clears EZ trap, tested pump; added treatment tabs to drain pan. Recommend wet switch: water safety device that will shut equipment down if water is detected on floor near equipment. Provided estimate Checked integrity of compressor motor (mega ohm test) Assessed refrigerant charge checked pressures. Good AC system operating well at this time. Need to decide whether they want to be billed for 1 time tune up ($89) or for plan membership( $189) recommend plan membership
Honey Brook, PA 19344
Completed AC tune up for 3 .5 Ton Carrier AC system
2 zones Honeywell zoning. 1st floor and master bedroom thermostats.
House was built in 2024

16x25x5 filter ok, recently replaced by homeowner 
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimates for surge protectors 
Measured temperature split (21°) and static pressure 
Inspected drains; cleared trap. Provided email estimate for EZ trap which is an AC drain trap with cleanout and overfill protection switch. 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. 14° SC Good

*There is a DAS (discharge air sensor) in the supply plenum. Its purpose is to shut off the outdoor unit (compressor) when the temperature drops below 40° and then cut the compressor back in when temperature rises to 45° during cooling operation, This is to avoid freezing indoor coil especially when only 1 zone is calling and to make system more effic
Completed AC tune up for 3 .5 Ton Carrier AC system
2 zones Honeywell zoning. 1st floor and master bedroom thermostats.
House was built in 2024

16x25x5 filter ok, recently replaced by homeowner 
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimates for surge protectors 
Measured temperature split (21°) and static pressure 
Inspected drains; cleared trap. Provided email estimate for EZ trap which is an AC drain trap with cleanout and overfill protection switch. 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. 14° SC Good

*There is a DAS (discharge air sensor) in the supply plenum. Its purpose is to shut off the outdoor unit (compressor) when the temperature drops below 40° and then cut the compressor back in when temperature rises to 45° during cooling operation, This is to avoid freezing indoor coil especially when only 1 zone is calling and to make system more effic
Barry P.
Barry P. Checked in
Completed AC tune up for 3 .5 Ton Carrier AC system 2 zones Honeywell zoning. 1st floor and master bedroom thermostats. House was built in 2024 16x25x5 filter ok, recently replaced by homeowner Indoor and outdoor coils in good condition Inspected wiring, controls, electric motors and components; left estimates for surge protectors Measured temperature split (21°) and static pressure Inspected drains; cleared trap. Provided email estimate for EZ trap which is an AC drain trap with cleanout and overfill protection switch. Checked integrity of compressor motor (mega ohm test) Assessed refrigerant charge checked pressures. 14° SC Good *There is a DAS (discharge air sensor) in the supply plenum. Its purpose is to shut off the outdoor unit (compressor) when the temperature drops below 40° and then cut the compressor back in when temperature rises to 45° during cooling operation, This is to avoid freezing indoor coil especially when only 1 zone is calling and to make system more effic
Honey Brook, PA 19344
Review
Barry was on time and provided exceptional service in a professional and informative manner. He’s not only a great tech, but a great ambassador for your company. Well done!!!
Les - Honey Brook, PA 19344
Review
Dan did a great job. He was thorough and explained everything that he did.
Kris - Honey Brook, PA 19344
Review
Dan is always professional, personable and proficient in his assessment of my equipment. He will inform me of any issues.
A - Honey Brook, PA 19344
Review
Never had any problems with my service
Sharon - Honey Brook, PA 19344
Review
Kurt was very prompted and very helpful by checking my heater and was very knowledgable. He was friendly and polite.
Barb - Honey Brook, PA 19344
Review
Great job
Paul - Honey Brook, PA 19344
Review
Installation today went well. The guys were very professional and it looks like they did a great job. And… it was nice to see a team of all American tradesmen for a change!
Paul B. - Honey Brook, PA 19344
Review
Tony Fiore was fantastic. Very knowledgeable and professional. He’s the kind of guy I would hire for my own business!
Paul - Honey Brook, PA 19344
Review
Its was a great person very professional and respectful
Filadelfa Linokk - Honey Brook, PA 19344
Response from DiBiase Heating and Cooling Company:

Hello! Thank you for your kind words! We’re glad to hear you had a great experience and that our team member was professional and respectful. We appreciate your trust in DiBiase Heating and Cooling!

Review
EXCELLENT SERVICE
Al - Honey Brook, PA 19344
Review
MaryBeth Wadlinger - Honey Brook, PA 19344
Response from DiBiase Heating and Cooling Company:

Hi MaryBeth! Thank you so much for taking the time to leave a 5-star review!

Review
Thank you DiBiase Company to come out and inspect the air conditioning system which I purchased a year ago. Isaac was friendly and courteous and went over in details on how is the system doing.
ELIZABETH KOVACH - Honey Brook, PA 19344
Response from DiBiase Heating and Cooling Company:

Hello Elizabeth! Thank you for the wonderful review! We’re so glad to hear you had a great experience from start to finish. Our team takes pride in being respectful, thorough, and helpful—both to our customers and their furry friends! We’re especially happy to hear Aaron made the follow-up visit smooth and informative. Thanks again for choosing DiBiase Heating and Cooling!

Review
MaryBeth Wadlinger - Honey Brook, PA 19344
Response from DiBiase Heating and Cooling Company:

Hello MaryBeth! We really appreciate you taking the time to leave a 5-star review!

Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next