610-873-1244 Book Online Text Us

Spring City, PA

Expert HVAC Service and More in Spring City, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Spring City, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in Spring City, PA

Rated 5.0 out of 5 stars based on 9 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express enthusiasm about the professionalism, efficiency, and expertise demonstrated by the service technicians. Recurring themes include praise for the friendly and courteous demeanor of staff members, with many reviewers highlighting how technicians take time to provide thorough explanations and patiently answer questions. The company's responsiveness stands out as a significant strength, with customers noting quick service, timely arrivals, and even after-hours and weekend availability during urgent situations. Technical competence is frequently celebrated, with reviewers expressing confidence in the quality of work performed and trust in the recommendations provided. Many customers specifically mention feeling valued and respected, noting that technicians are considerate of their property and demonstrate genuine care in their interactions. The positive experiences have fostered strong loyalty, with some customers indicating they have switched to this company from previous providers or expressing intent to request specific technicians for future visits. The tone throughout is one of gratitude and recommendation, with customers frequently using words like "excellent," "wonderful," "great," and "highly recommend" to convey their satisfaction with both the technical service and interpersonal experience.

Our Local Reviews by City

Job Locations and Reviews

5/26/26. Performed precision a/c tune up on 2024 Lennox inverter heat pump system. Replaced 20x25x4 air filter ( provided by homeowner). Checked all electrical connections and components. Checked temperature split. Flushed condensation drain. Found no surge protection on gas furnace with several electronics on system. Highly recommended surge protection. Installed ag3000 surge protector. Did not check refrigerant pressures due to being critical charge. Heat pump is working properly at time of service.
5/26/26. Performed precision a/c tune up on 2024 Lennox inverter heat pump system. Replaced 20x25x4 air filter ( provided by homeowner). Checked all electrical connections and components. Checked temperature split. Flushed condensation drain. Found no surge protection on gas furnace with several electronics on system. Highly recommended surge protection. Installed ag3000 surge protector. Did not check refrigerant pressures due to being critical charge. Heat pump is working properly at time of service.
Kurt M.
Kurt M. Checked in
5/26/26. Performed precision a/c tune up on 2024 Lennox inverter heat pump system. Replaced 20x25x4 air filter ( provided by homeowner). Checked all electrical connections and components. Checked temperature split. Flushed condensation drain. Found no surge protection on gas furnace with several electronics on system. Highly recommended surge protection. Installed ag3000 surge protector. Did not check refrigerant pressures due to being critical charge. Heat pump is working properly at time of service.
Spring City, PA 19475
Luis T.
Luis T. Checked in
Luis 4-6-26 return visit to install check valve on hydronic system, drain boiler and installed check valve, after repairs test operation and bleed air ok. all radiators getting hot, test hot water and no heat migration from hydronic piping. No charge warranty from installation
Spring City, PA 19475
Est
Est
Diilon M.
Diilon M. Checked in
Est
Spring City, PA 19475
Est
Est
Diilon M.
Diilon M. Checked in
Est
Spring City, PA 19475
3/23/26 Kurt + Liz
4 AC Tuneups on 13 year old R410A Carrier Air Conditioners. 

Started at indoor systems, checked all electrical connections, all electrical components functioning properly. Tested return and supply temperatures, all systems have appropriate temp split. Checked static on all 4 systems/ static ok. 

Visually inspected coils and blower motors , all in ok condition. Poured water down drain lines to ensure there are no blockages and that there is proper drainage. Did notice no system has surge protection, informed customer of benefits of surge protection. 

At outdoor checked all electrical connections including total system voltage, compressor amps, and capacitors, all electrical components functioning properly on all 4 systems. 

Checked refrigerant levels on all systems, refrigerant levels in good range. 

All systems operational at time of service but past age of life expectancy.
3/23/26 Kurt + Liz
4 AC Tuneups on 13 year old R410A Carrier Air Conditioners. 

Started at indoor systems, checked all electrical connections, all electrical components functioning properly. Tested return and supply temperatures, all systems have appropriate temp split. Checked static on all 4 systems/ static ok. 

Visually inspected coils and blower motors , all in ok condition. Poured water down drain lines to ensure there are no blockages and that there is proper drainage. Did notice no system has surge protection, informed customer of benefits of surge protection. 

At outdoor checked all electrical connections including total system voltage, compressor amps, and capacitors, all electrical components functioning properly on all 4 systems. 

Checked refrigerant levels on all systems, refrigerant levels in good range. 

All systems operational at time of service but past age of life expectancy.
Kurt M.
Kurt M. Checked in
3/23/26 Kurt + Liz 4 AC Tuneups on 13 year old R410A Carrier Air Conditioners. Started at indoor systems, checked all electrical connections, all electrical components functioning properly. Tested return and supply temperatures, all systems have appropriate temp split. Checked static on all 4 systems/ static ok. Visually inspected coils and blower motors , all in ok condition. Poured water down drain lines to ensure there are no blockages and that there is proper drainage. Did notice no system has surge protection, informed customer of benefits of surge protection. At outdoor checked all electrical connections including total system voltage, compressor amps, and capacitors, all electrical components functioning properly on all 4 systems. Checked refrigerant levels on all systems, refrigerant levels in good range. All systems operational at time of service but past age of life expectancy.
Spring City, PA 19475
Propane gas boiler not working properly, found error f6 showing on display.  high limit issue, not enough circulation across heat exchanger. Check primary secondary circulation pump (f10 taco) found seized motor. I replaced circulation pump taco 007. I check piping and all piping starting to get hot. I did measure temperature on the return and supply. I noticed  left side of the boiler by the air elimination started to get hot first and then the one on the right it was cold water coming back.  This will help installers when we install new boiler, no charge for Today I talked to Joe while on site.
Propane gas boiler not working properly, found error f6 showing on display.  high limit issue, not enough circulation across heat exchanger. Check primary secondary circulation pump (f10 taco) found seized motor. I replaced circulation pump taco 007. I check piping and all piping starting to get hot. I did measure temperature on the return and supply. I noticed  left side of the boiler by the air elimination started to get hot first and then the one on the right it was cold water coming back.  This will help installers when we install new boiler, no charge for Today I talked to Joe while on site.
Luis T.
Luis T. Checked in
Propane gas boiler not working properly, found error f6 showing on display. high limit issue, not enough circulation across heat exchanger. Check primary secondary circulation pump (f10 taco) found seized motor. I replaced circulation pump taco 007. I check piping and all piping starting to get hot. I did measure temperature on the return and supply. I noticed left side of the boiler by the air elimination started to get hot first and then the one on the right it was cold water coming back. This will help installers when we install new boiler, no charge for Today I talked to Joe while on site.
Spring City, PA 19475
Joseph D.
Joseph D. Checked in
Completed creating estimate for new boiler and sent estimate to Greg.
Spring City, PA 19475
Review
Kurt is very knowledgeable and explains everything in detail about our systems.
Greg Orzeck - Spring City, PA 19475
Daikin mini split heat pump.
 Found system low on charge. Only blowing out 82 degree air temperature. Found that a flare joint at the outside unit was leaking refrigerant. Bubble checked and tightened up fitting. Added in factory charge of 2 lbs 3 ozs. And tested out mini split in heating mode. Now system is performing at a 30 degree temperature rise and refrigarant pressure is 350 psi. 
No charge per management.
Amana heat pump system 
 Performed heat tune up on 2023 amana heat pump system. 20x23x1 air filter is ok. Checked all electrical connections and components. Changed ecobee to permanent hold mode. Checked refrigerant pressures and temperatures. ( took photos). Heat pump is working properly at time of service. 
Munchkin gas boiler. 
 Found boiler heating properly but purring like a diesel engine. Explained to Greg that this could possibly be a draft inducer motor and gas valve issue. Boiler is from 2006. Recommended replacement with a Laars boiler. Took video of noise. Also foun
Daikin mini split heat pump.
 Found system low on charge. Only blowing out 82 degree air temperature. Found that a flare joint at the outside unit was leaking refrigerant. Bubble checked and tightened up fitting. Added in factory charge of 2 lbs 3 ozs. And tested out mini split in heating mode. Now system is performing at a 30 degree temperature rise and refrigarant pressure is 350 psi. 
No charge per management.
Amana heat pump system 
 Performed heat tune up on 2023 amana heat pump system. 20x23x1 air filter is ok. Checked all electrical connections and components. Changed ecobee to permanent hold mode. Checked refrigerant pressures and temperatures. ( took photos). Heat pump is working properly at time of service. 
Munchkin gas boiler. 
 Found boiler heating properly but purring like a diesel engine. Explained to Greg that this could possibly be a draft inducer motor and gas valve issue. Boiler is from 2006. Recommended replacement with a Laars boiler. Took video of noise. Also foun
Kurt M.
Kurt M. Checked in
Daikin mini split heat pump. Found system low on charge. Only blowing out 82 degree air temperature. Found that a flare joint at the outside unit was leaking refrigerant. Bubble checked and tightened up fitting. Added in factory charge of 2 lbs 3 ozs. And tested out mini split in heating mode. Now system is performing at a 30 degree temperature rise and refrigarant pressure is 350 psi. No charge per management. Amana heat pump system Performed heat tune up on 2023 amana heat pump system. 20x23x1 air filter is ok. Checked all electrical connections and components. Changed ecobee to permanent hold mode. Checked refrigerant pressures and temperatures. ( took photos). Heat pump is working properly at time of service. Munchkin gas boiler. Found boiler heating properly but purring like a diesel engine. Explained to Greg that this could possibly be a draft inducer motor and gas valve issue. Boiler is from 2006. Recommended replacement with a Laars boiler. Took video of noise. Also foun
Spring City, PA 19475
Est
Est
Diilon M.
Diilon M. Checked in
Est
Spring City, PA 19475
Fully assessed no heating situation. Mucking propane boiler which heats hard wood floors was running fine when I arrived, took photos of pipe temperatures. Did find 2023 amana heat pump locked out on code L2 high pressure lock out. . Reset heat pump and checked refrigerant pressures they were r410a 254/50 very good. Temperature rise was 17 degrees at 9 degrees outside ambient temperature very good. Heat pump systems are designed down to 15 degrees anything lower that that they will struggle to keep temp also system does not use auxiliary heat, auxiliary heat is the boiler system. Found air filter was also very dirty 20x24x1, homeowner to replace. This can definitely cause a high pressure lockout in heating mode. Heat pump is working properly again at time of service. Showed homeowner how to reset in case of extreme low temperature.
Fully assessed no heating situation. Mucking propane boiler which heats hard wood floors was running fine when I arrived, took photos of pipe temperatures. Did find 2023 amana heat pump locked out on code L2 high pressure lock out. . Reset heat pump and checked refrigerant pressures they were r410a 254/50 very good. Temperature rise was 17 degrees at 9 degrees outside ambient temperature very good. Heat pump systems are designed down to 15 degrees anything lower that that they will struggle to keep temp also system does not use auxiliary heat, auxiliary heat is the boiler system. Found air filter was also very dirty 20x24x1, homeowner to replace. This can definitely cause a high pressure lockout in heating mode. Heat pump is working properly again at time of service. Showed homeowner how to reset in case of extreme low temperature.
Kurt M.
Kurt M. Checked in
Fully assessed no heating situation. Mucking propane boiler which heats hard wood floors was running fine when I arrived, took photos of pipe temperatures. Did find 2023 amana heat pump locked out on code L2 high pressure lock out. . Reset heat pump and checked refrigerant pressures they were r410a 254/50 very good. Temperature rise was 17 degrees at 9 degrees outside ambient temperature very good. Heat pump systems are designed down to 15 degrees anything lower that that they will struggle to keep temp also system does not use auxiliary heat, auxiliary heat is the boiler system. Found air filter was also very dirty 20x24x1, homeowner to replace. This can definitely cause a high pressure lockout in heating mode. Heat pump is working properly again at time of service. Showed homeowner how to reset in case of extreme low temperature.
Spring City, PA 19475
Review
Efficient, knowledgeable and personable!!
Susan - Spring City, PA 19475
Review
I cannot recommend DiBiase enough! They show up when they say they will, communication is great and Kurt the technician and his coworker were great representatives of the company! Kurt explained what happened and did a thorough job. Oh and they came out the same day I called. DiBiase will be my go to company from here on out!
Samantha - Spring City, PA 19475
Review
Excellent Service!!
Srividya - Spring City, PA 19475
Review
Tony was very thorough with his explanation. Great with people. Lucky to have him as a comfort consultant.
Meacham Family - Spring City, PA 19475
Response from DiBiase Heating and Cooling Company:

Hey Meacham Family! Thank you for the thoughtful review! We're so glad to hear that Tony provided a thorough explanation and made a great impression. We agree—he’s a fantastic comfort consultant, and we’re lucky to have him on the team!

Review
He did wonderful service
RJB - Spring City, PA 19475
Response from DiBiase Heating and Cooling Company:

Thank you for taking the time to share your experience and we look forward to welcoming you back soon!

Review
Dan was on time and efficient. He was very informative every step of the way making sure we knew what he was doing g what he found and answering any questions. I highly recommend DiBiase. They are small, family owned and the communication from my initial phone call to the end of the appointment was excellent. Couldn’t be happier with the entire experience.
Samantha - Spring City, PA 19475
Review
Kurt was very knowledgeable and did a great job explaining everything to us.
Susan - Spring City, PA 19475
Review
Barry was prompt, professional and courteous. He brought his tool bag along and it felt like he was serious about getting the problem solved and not like let me look and decide. He did a through check on the HVAC and also did some preventative maintenance. Also suggested options on what can help in the long run. I Will definitely suggest DiBiase H&C to family and friends based on the positive experience
Srividya - Spring City, PA 19475
Review
Very thorough and thoughtful. Explained everything so we could understand the problem. Spent a great deal of time to make sure everything was right before he left, even though it was just 2 days before Xmas.
Susan - Spring City, PA 19475
Response from DiBiase Heating and Cooling Company:

We are so glad to hear that you had a good experience.

Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next