610-873-1244 Book Online Text Us

Thornbury Township, PA

Expert HVAC Service and More in Thornbury Township, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Thornbury Township, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in Thornbury Township, PA

Rated 5.0 out of 5 stars based on 3 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction with the service provided. Customers consistently express appreciation for the professionalism, efficiency, and expertise demonstrated by the technicians. A dominant theme throughout is the promptness of service, with many reviewers noting quick response times, same-day repairs, and technicians arriving within hours of initial contact. The technical staff receives particular praise for their knowledge and diagnostic abilities, with customers frequently highlighting how problems were identified and resolved quickly and effectively. Another recurring positive sentiment centers on communication and customer education—reviewers repeatedly commend technicians for taking time to explain issues in detail, offering multiple options based on budget considerations, and providing helpful maintenance tips for the future. The personable and friendly nature of the service providers is mentioned consistently, contributing to a welcoming and trustworthy experience. Customers also express relief and gratitude when seemingly major problems turn out to have simple solutions, appreciating the honesty and transparency demonstrated. The thoroughness of inspections and the quality of workmanship are additional strengths noted across multiple reviews. Overall, the tone is enthusiastically positive, with strong recommendations for both the company and individual technicians, and customers expressing confidence in requesting specific service providers for future needs.

Thornbury Township, PA at a glance

DiBiase Heating and Cooling Company has completed 10 jobs in Thornbury Township, PA between March 2026 and September 2026.

The 4 customer reviews shown here average 5.0 out of 5.

The most recent job was on September 3, 2026.

Our Local Reviews by City

Job Locations and Reviews

Completed QA 4 Ton Heat pump. 
2 Oil hydronic zones, (2) EIMs with S12000 Thermostats. Balance point 30° Aux heat lockout 45°. *Verified that when defrost W energizes it will bring on 10KW electric heat. Explained defrost to homeowner because this is his first heat pump. Had AC with oil hydronics before. 

Inspected all aspects of install: mechanical, ductwork connections, wiring, configuration of thermostat and controls, fan speed tap (TAP8 for 4 Ton)

Checked refrigerant diagnostics and temperature split: 7° SC 11.5 SH, 20°delta T.

Homeowner still needs to connect thermostats to WiFi for outdoor temperature input. 

Install passes QA inspection
Completed QA 4 Ton Heat pump. 
2 Oil hydronic zones, (2) EIMs with S12000 Thermostats. Balance point 30° Aux heat lockout 45°. *Verified that when defrost W energizes it will bring on 10KW electric heat. Explained defrost to homeowner because this is his first heat pump. Had AC with oil hydronics before. 

Inspected all aspects of install: mechanical, ductwork connections, wiring, configuration of thermostat and controls, fan speed tap (TAP8 for 4 Ton)

Checked refrigerant diagnostics and temperature split: 7° SC 11.5 SH, 20°delta T.

Homeowner still needs to connect thermostats to WiFi for outdoor temperature input. 

Install passes QA inspection
Barry P.
Barry P. Checked in
Completed QA 4 Ton Heat pump. 2 Oil hydronic zones, (2) EIMs with S12000 Thermostats. Balance point 30° Aux heat lockout 45°. *Verified that when defrost W energizes it will bring on 10KW electric heat. Explained defrost to homeowner because this is his first heat pump. Had AC with oil hydronics before. Inspected all aspects of install: mechanical, ductwork connections, wiring, configuration of thermostat and controls, fan speed tap (TAP8 for 4 Ton) Checked refrigerant diagnostics and temperature split: 7° SC 11.5 SH, 20°delta T. Homeowner still needs to connect thermostats to WiFi for outdoor temperature input. Install passes QA inspection
Thornbury Township, PA 19373
08/25/26 Dan 

I arrived to the service call to replace a blower motor. Ed was out here on the 24th. I went through the diagnostic to confirm and the board has the voltages calling for cool and is sending voltage to the motor. I deemed the blower motor failed. I removed and replaced the blower motor. I turned the system back on and still no blower motor, also noticed the board is not displaying on the LED , the light should be a solid green.  So the water that got into the blower compartment from the clogged drain must have damage the blower motor and control board as well   office going to order a new board . Should be in next day .
08/25/26 Dan 

I arrived to the service call to replace a blower motor. Ed was out here on the 24th. I went through the diagnostic to confirm and the board has the voltages calling for cool and is sending voltage to the motor. I deemed the blower motor failed. I removed and replaced the blower motor. I turned the system back on and still no blower motor, also noticed the board is not displaying on the LED , the light should be a solid green.  So the water that got into the blower compartment from the clogged drain must have damage the blower motor and control board as well   office going to order a new board . Should be in next day .
Daniel R.
Daniel R. Checked in
08/25/26 Dan I arrived to the service call to replace a blower motor. Ed was out here on the 24th. I went through the diagnostic to confirm and the board has the voltages calling for cool and is sending voltage to the motor. I deemed the blower motor failed. I removed and replaced the blower motor. I turned the system back on and still no blower motor, also noticed the board is not displaying on the LED , the light should be a solid green. So the water that got into the blower compartment from the clogged drain must have damage the blower motor and control board as well office going to order a new board . Should be in next day .
Thornbury Township, PA 19342
Estimate
Estimate
Diilon M.
Diilon M. Checked in
Estimate
Thornbury Township, PA 19342
Review
Very thorough and professional.
Michele - Thornbury Township, PA 19342
8/12/26. Performed precision a/c tune up on climate master geothermal and Daikin heat pump system. Replaced both 1” air filters. Checked all electrical connections and components. Checked loop pressures on geothermal found it to be 0 psi. Recommended adding water to the loop. Pushed loop pressure up to 40 psi. Checked temperature splits on both systems. Tested capacitors. Checked refrigerant pressures and temperatures. Found no surge protection on attic blower motor and no ez trap for condensation drain. Installed and tested operation. Both systems are working properly at time of service.
8/12/26. Performed precision a/c tune up on climate master geothermal and Daikin heat pump system. Replaced both 1” air filters. Checked all electrical connections and components. Checked loop pressures on geothermal found it to be 0 psi. Recommended adding water to the loop. Pushed loop pressure up to 40 psi. Checked temperature splits on both systems. Tested capacitors. Checked refrigerant pressures and temperatures. Found no surge protection on attic blower motor and no ez trap for condensation drain. Installed and tested operation. Both systems are working properly at time of service.
Kurt M.
Kurt M. Checked in
8/12/26. Performed precision a/c tune up on climate master geothermal and Daikin heat pump system. Replaced both 1” air filters. Checked all electrical connections and components. Checked loop pressures on geothermal found it to be 0 psi. Recommended adding water to the loop. Pushed loop pressure up to 40 psi. Checked temperature splits on both systems. Tested capacitors. Checked refrigerant pressures and temperatures. Found no surge protection on attic blower motor and no ez trap for condensation drain. Installed and tested operation. Both systems are working properly at time of service.
Thornbury Township, PA 19342
6/8/26. Fully assessed no cooling on 2023 Bosch heat pump installed by dibiase. Found everything running except outside condenser fan motor. Called Bosch tech support and tested out motor and board output voltage, all tested ok. After resetting system fan came on but found 410a refrigerant pressures low 177/58. Went over entire system with electronic leak detecter did not find any leaks. Recommend we add refrigerant and leak dye to the system and complete tune up. Added 3lbs to the system and leak dye. Now refrigerant pressures are 284/134 with 8 subcooling. Performed tune up. Replaced 20x25x4 air filter. Checked all electrical connections and components. Flushed out drain. Checked temperature split. System is working properly at time of service. Do not know how long charge will last. Now that there is dye in the system we should be able to locate refrigerant leak in the future.
6/8/26. Fully assessed no cooling on 2023 Bosch heat pump installed by dibiase. Found everything running except outside condenser fan motor. Called Bosch tech support and tested out motor and board output voltage, all tested ok. After resetting system fan came on but found 410a refrigerant pressures low 177/58. Went over entire system with electronic leak detecter did not find any leaks. Recommend we add refrigerant and leak dye to the system and complete tune up. Added 3lbs to the system and leak dye. Now refrigerant pressures are 284/134 with 8 subcooling. Performed tune up. Replaced 20x25x4 air filter. Checked all electrical connections and components. Flushed out drain. Checked temperature split. System is working properly at time of service. Do not know how long charge will last. Now that there is dye in the system we should be able to locate refrigerant leak in the future.
Kurt M.
Kurt M. Checked in
6/8/26. Fully assessed no cooling on 2023 Bosch heat pump installed by dibiase. Found everything running except outside condenser fan motor. Called Bosch tech support and tested out motor and board output voltage, all tested ok. After resetting system fan came on but found 410a refrigerant pressures low 177/58. Went over entire system with electronic leak detecter did not find any leaks. Recommend we add refrigerant and leak dye to the system and complete tune up. Added 3lbs to the system and leak dye. Now refrigerant pressures are 284/134 with 8 subcooling. Performed tune up. Replaced 20x25x4 air filter. Checked all electrical connections and components. Flushed out drain. Checked temperature split. System is working properly at time of service. Do not know how long charge will last. Now that there is dye in the system we should be able to locate refrigerant leak in the future.
Thornbury Township, PA 19373
Completed (3) AC tune ups. All 3 systems are gas furnace+AC installed within last 3 years. Addition, 1st Fl. And 2nd Fl.

Replaced all filters provided by homeowner. Aprilaire 413, 16x25x1, 16x20x1

For each system:
Completed AC tune up for 3 Ton Amana AC system

Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimates for surge protectors. On estimate is for (3) surge protectors for indoor equipment circuits. The other is for (2) for the outdoor units for the addition and 1st floor systems. 
Measured temperature split and static pressure 
Inspected drains; cleared EZ trap, tested pumps added treatment tabs to drain pans. 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. 

AC systems are operating well at this time.
Completed (3) AC tune ups. All 3 systems are gas furnace+AC installed within last 3 years. Addition, 1st Fl. And 2nd Fl.

Replaced all filters provided by homeowner. Aprilaire 413, 16x25x1, 16x20x1

For each system:
Completed AC tune up for 3 Ton Amana AC system

Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimates for surge protectors. On estimate is for (3) surge protectors for indoor equipment circuits. The other is for (2) for the outdoor units for the addition and 1st floor systems. 
Measured temperature split and static pressure 
Inspected drains; cleared EZ trap, tested pumps added treatment tabs to drain pans. 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. 

AC systems are operating well at this time.
Barry P.
Barry P. Checked in
Completed (3) AC tune ups. All 3 systems are gas furnace+AC installed within last 3 years. Addition, 1st Fl. And 2nd Fl. Replaced all filters provided by homeowner. Aprilaire 413, 16x25x1, 16x20x1 For each system: Completed AC tune up for 3 Ton Amana AC system Indoor and outdoor coils in good condition Inspected wiring, controls, electric motors and components; left estimates for surge protectors. On estimate is for (3) surge protectors for indoor equipment circuits. The other is for (2) for the outdoor units for the addition and 1st floor systems. Measured temperature split and static pressure Inspected drains; cleared EZ trap, tested pumps added treatment tabs to drain pans. Checked integrity of compressor motor (mega ohm test) Assessed refrigerant charge checked pressures. AC systems are operating well at this time.
Thornbury Township, PA 19342
4/15/26
 Fully assessed no cooling situation on 2022 geothermal package system. Found geo working when I arrived. Took off cover at blower compartment and found drain pan did have some build up in it. Poorer water in pan , it did drain away just slowly. Flushed out trap with hot water, this did not cause the no cooling though. Found while I was on site. Geothermal locked out on a code (5) low coil temp code. Found very dirty air filter. Replaced air filter with one he provided. Check air temperature split it was 22 degrees. Also checked water temperature split it was 11 degrees. Geothermal is working properly at time of service. Customer signed up for maintenance plan for all (3) geothermal systems.
4/15/26
 Fully assessed no cooling situation on 2022 geothermal package system. Found geo working when I arrived. Took off cover at blower compartment and found drain pan did have some build up in it. Poorer water in pan , it did drain away just slowly. Flushed out trap with hot water, this did not cause the no cooling though. Found while I was on site. Geothermal locked out on a code (5) low coil temp code. Found very dirty air filter. Replaced air filter with one he provided. Check air temperature split it was 22 degrees. Also checked water temperature split it was 11 degrees. Geothermal is working properly at time of service. Customer signed up for maintenance plan for all (3) geothermal systems.
Kurt M.
Kurt M. Checked in
4/15/26 Fully assessed no cooling situation on 2022 geothermal package system. Found geo working when I arrived. Took off cover at blower compartment and found drain pan did have some build up in it. Poorer water in pan , it did drain away just slowly. Flushed out trap with hot water, this did not cause the no cooling though. Found while I was on site. Geothermal locked out on a code (5) low coil temp code. Found very dirty air filter. Replaced air filter with one he provided. Check air temperature split it was 22 degrees. Also checked water temperature split it was 11 degrees. Geothermal is working properly at time of service. Customer signed up for maintenance plan for all (3) geothermal systems.
Thornbury Township, PA 19342
Est
Est
Diilon M.
Diilon M. Checked in
Est
Thornbury Township, PA 19373
Went through the customers home to verify that the gas lines are bonded and aren’t leaking and also been sleeved and strapped up. Went around to the gas lines with my gas leak sniffer and found no leaks. I  also checked the manifold for all the appliances and the manifold is fine . The gas lines are strapped up and secured. Everything is good here with the house no gas leaks and lines are secured and sleeved. 


I did leave an estimate for the customers for a new humidifier. I left two different options for the humidifier. And I left an estimate for a service contract . 

I also left an estimate for a natural gas natural draft water heater 50 gallon. It’s 12 years old and  Should be replaced  around a 10 year mark. I left the customer with two water heater options .
Went through the customers home to verify that the gas lines are bonded and aren’t leaking and also been sleeved and strapped up. Went around to the gas lines with my gas leak sniffer and found no leaks. I  also checked the manifold for all the appliances and the manifold is fine . The gas lines are strapped up and secured. Everything is good here with the house no gas leaks and lines are secured and sleeved. 


I did leave an estimate for the customers for a new humidifier. I left two different options for the humidifier. And I left an estimate for a service contract . 

I also left an estimate for a natural gas natural draft water heater 50 gallon. It’s 12 years old and  Should be replaced  around a 10 year mark. I left the customer with two water heater options .
Daniel R.
Daniel R. Checked in
Went through the customers home to verify that the gas lines are bonded and aren’t leaking and also been sleeved and strapped up. Went around to the gas lines with my gas leak sniffer and found no leaks. I also checked the manifold for all the appliances and the manifold is fine . The gas lines are strapped up and secured. Everything is good here with the house no gas leaks and lines are secured and sleeved. I did leave an estimate for the customers for a new humidifier. I left two different options for the humidifier. And I left an estimate for a service contract . I also left an estimate for a natural gas natural draft water heater 50 gallon. It’s 12 years old and Should be replaced around a 10 year mark. I left the customer with two water heater options .
Thornbury Township, PA 19342
Checked over gas piping.
Gas piping is secure and anchored with appropriate clamps in multiple spots.
Gas pipe from the meter penetrates through the house above the concrete foundation at plywood sheathing as a 1” galvanized hard pipe with a collar mating around against siding. This pipe is in good condition. No flexible gas piping penetrates through any hard exterior walls. 

Flexible trap pipe is bonded to ground vial the water line where it comes into house.
Did a leak search on furnace piping.

Gas piping passes inspection.
Checked over gas piping.
Gas piping is secure and anchored with appropriate clamps in multiple spots.
Gas pipe from the meter penetrates through the house above the concrete foundation at plywood sheathing as a 1” galvanized hard pipe with a collar mating around against siding. This pipe is in good condition. No flexible gas piping penetrates through any hard exterior walls. 

Flexible trap pipe is bonded to ground vial the water line where it comes into house.
Did a leak search on furnace piping.

Gas piping passes inspection.
Barry P.
Barry P. Checked in
Checked over gas piping. Gas piping is secure and anchored with appropriate clamps in multiple spots. Gas pipe from the meter penetrates through the house above the concrete foundation at plywood sheathing as a 1” galvanized hard pipe with a collar mating around against siding. This pipe is in good condition. No flexible gas piping penetrates through any hard exterior walls. Flexible trap pipe is bonded to ground vial the water line where it comes into house. Did a leak search on furnace piping. Gas piping passes inspection.
Thornbury Township, PA 19342
Review
We’ve had DiBiase service our units for years and they’re always prompt, friendly, progressional and fair priced. Our appt with Daniel today was great - I’d expect nothing less.
Kristen - Thornbury Township, PA 19342
Review
Kurt was a pleasure. Great attitude nice disposition .Very thorough and explained all my questions. Thank You. I'll have him back anytime. He explained different options. Need to make appointment for new service.
Gregory - Thornbury Township, PA 19342
Review
Polite, on time, well knowledgeable
juliana soares - Thornbury Township, PA 19342
Response from DiBiase Heating and Cooling Company:

Hi Juliana, Thank you for the kind review! We're glad to hear you had a positive experience. If you ever need anything, we're here to help!

Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next