Expert HVAC Service and More in Newtown Square, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Newtown Square, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in Newtown Square, PA

Rated 5.0 out of 5 stars based on 11 customer reviews

Customers say: The reviews reflect an overwhelmingly positive sentiment toward the HVAC service provided. Customers consistently express appreciation for technicians who are knowledgeable, professional, and efficient in diagnosing and resolving heating issues. The tone across the collection is predominantly positive, with recurring themes of excellent communication, thorough explanations of technical matters, and prompt service—particularly valued during emergency situations in cold weather. Customers frequently highlight the technicians' ability to clearly explain system operations, maintenance recommendations, and available options. The service is repeatedly characterized as courteous and professional, with many customers noting the technicians' transparency and helpfulness. Customers also appreciate the absence of aggressive upselling and the technicians' dedication to resolving problems completely. Overall, the reviews convey a strong sense of customer satisfaction and trust in the technical expertise and customer service provided.

Our Local Reviews by City

Job Locations and Reviews

Completed heat tune up for heat pump with 15KW electric heat kit,
Installed by Dibiase April 2024. 

Replaced 20x25x4 filter provided by homeowner 
Indoor and outdoor coils in good condition.
Inspected wiring, controls, electric motors and components. 15KW electric heat kit 60A Good
Measured temperature rise and static pressure
Inspected drains. 
Verified defrost cycle 
Checked R410Arefrigerant charge/pressures. 388/65 matches manufacturer chart, 

Heat pump operating well at this time.

Current UV light system has bulb that has not been replaced in years. Model number of system is BioFighter 2S16 120V. I could not find matching UV replacement bulb so I provided estimates for new UV systems. 1 estimate for single bulb. 1 estimate for APCOX air treatment system.

Provided email estimate for plan membership.
Completed heat tune up for heat pump with 15KW electric heat kit,
Installed by Dibiase April 2024. 

Replaced 20x25x4 filter provided by homeowner 
Indoor and outdoor coils in good condition.
Inspected wiring, controls, electric motors and components. 15KW electric heat kit 60A Good
Measured temperature rise and static pressure
Inspected drains. 
Verified defrost cycle 
Checked R410Arefrigerant charge/pressures. 388/65 matches manufacturer chart, 

Heat pump operating well at this time.

Current UV light system has bulb that has not been replaced in years. Model number of system is BioFighter 2S16 120V. I could not find matching UV replacement bulb so I provided estimates for new UV systems. 1 estimate for single bulb. 1 estimate for APCOX air treatment system.

Provided email estimate for plan membership.
Barry P.
Barry P. Checked in
Completed heat tune up for heat pump with 15KW electric heat kit, Installed by Dibiase April 2024. Replaced 20x25x4 filter provided by homeowner Indoor and outdoor coils in good condition. Inspected wiring, controls, electric motors and components. 15KW electric heat kit 60A Good Measured temperature rise and static pressure Inspected drains. Verified defrost cycle Checked R410Arefrigerant charge/pressures. 388/65 matches manufacturer chart, Heat pump operating well at this time. Current UV light system has bulb that has not been replaced in years. Model number of system is BioFighter 2S16 120V. I could not find matching UV replacement bulb so I provided estimates for new UV systems. 1 estimate for single bulb. 1 estimate for APCOX air treatment system. Provided email estimate for plan membership.
Newtown Square, PA 19073
Found 1st floor unit cutting off on high limit.
Very dirty filter, caked in drywall dust. They had just replaced 1/15/26… must be pockets of drywall dust in the returns. Explained how to check for this at return registers.
Also found some water in burner compartment coming from inducer. Caulked part of inducer that is leaking and left estimate to replace under parts warranty. Parts warranty expires 5/1/26.
Strapped water heater exhaust.
Removed bird from furnace exhaust. Explained how to cover exhaust with window screen at exhaust. I didn’t have any to offer. 

Found second floor inducer leaking as well. Provided email estimates. 1 to caulk and another to replace inducer. 
Provided estimates for wet switches and blower motor surge protectors as well.

1st floor Furnace passes combustion analysis testing
Found 1st floor unit cutting off on high limit.
Very dirty filter, caked in drywall dust. They had just replaced 1/15/26… must be pockets of drywall dust in the returns. Explained how to check for this at return registers.
Also found some water in burner compartment coming from inducer. Caulked part of inducer that is leaking and left estimate to replace under parts warranty. Parts warranty expires 5/1/26.
Strapped water heater exhaust.
Removed bird from furnace exhaust. Explained how to cover exhaust with window screen at exhaust. I didn’t have any to offer. 

Found second floor inducer leaking as well. Provided email estimates. 1 to caulk and another to replace inducer. 
Provided estimates for wet switches and blower motor surge protectors as well.

1st floor Furnace passes combustion analysis testing
Barry P.
Barry P. Checked in
Found 1st floor unit cutting off on high limit. Very dirty filter, caked in drywall dust. They had just replaced 1/15/26… must be pockets of drywall dust in the returns. Explained how to check for this at return registers. Also found some water in burner compartment coming from inducer. Caulked part of inducer that is leaking and left estimate to replace under parts warranty. Parts warranty expires 5/1/26. Strapped water heater exhaust. Removed bird from furnace exhaust. Explained how to cover exhaust with window screen at exhaust. I didn’t have any to offer. Found second floor inducer leaking as well. Provided email estimates. 1 to caulk and another to replace inducer. Provided estimates for wet switches and blower motor surge protectors as well. 1st floor Furnace passes combustion analysis testing
Newtown Square, PA 19073
Luis 1-28-26 performed quality assurance on recently installed full system gas heat 80% and ac unit. Check system operation, customer brought up some concerns about the heating system issues with the thermostat found the thermostat was going back to scheduling which was 62° room temperature. I disable scheduling per customer. I check all settings on control board. Check static pressure and temp rise. I noticed error codes on control board. EeE, EBL those codes refer to blower motor issue. I took cover off and inspect wiring ok. I increase airflow to next number up. Temperature rise for low heat 45 degrees. High stage heat 50 degrees. Total external static pressure .55 wc at high stage. And .48 wc low stage. I cleared  error codes in case customer has issues we will now they are current codes. I also added A2l sensor was never installed to unit and a2l setting was disable a control module. System has sensor now. I took photos of water heater there are couple dents that Neal was able to
Luis 1-28-26 performed quality assurance on recently installed full system gas heat 80% and ac unit. Check system operation, customer brought up some concerns about the heating system issues with the thermostat found the thermostat was going back to scheduling which was 62° room temperature. I disable scheduling per customer. I check all settings on control board. Check static pressure and temp rise. I noticed error codes on control board. EeE, EBL those codes refer to blower motor issue. I took cover off and inspect wiring ok. I increase airflow to next number up. Temperature rise for low heat 45 degrees. High stage heat 50 degrees. Total external static pressure .55 wc at high stage. And .48 wc low stage. I cleared  error codes in case customer has issues we will now they are current codes. I also added A2l sensor was never installed to unit and a2l setting was disable a control module. System has sensor now. I took photos of water heater there are couple dents that Neal was able to
Luis T.
Luis T. Checked in
Luis 1-28-26 performed quality assurance on recently installed full system gas heat 80% and ac unit. Check system operation, customer brought up some concerns about the heating system issues with the thermostat found the thermostat was going back to scheduling which was 62° room temperature. I disable scheduling per customer. I check all settings on control board. Check static pressure and temp rise. I noticed error codes on control board. EeE, EBL those codes refer to blower motor issue. I took cover off and inspect wiring ok. I increase airflow to next number up. Temperature rise for low heat 45 degrees. High stage heat 50 degrees. Total external static pressure .55 wc at high stage. And .48 wc low stage. I cleared error codes in case customer has issues we will now they are current codes. I also added A2l sensor was never installed to unit and a2l setting was disable a control module. System has sensor now. I took photos of water heater there are couple dents that Neal was able to
Newtown Square, PA 19073
Baby/nursery room got down to 63 last night again.
They are paying $2,500 a month in propane. 650 gallons last few months. 
Boiler size is 204,000 input 170,000 Output 
Square footage is 6000
There’s an additional 700 in basement where there is electric baseboard. 

Nursery room is 14x22=308 sq ft Required BTUs (308x45= 13,860)
25 linear feet of baseboard (25x600 btu per linear ft = 15,000 BTU)
Baseboard is adequate for this room.

I did notice that a pipe clamp thermocouple measured at the supply pipe was a few degrees cooler than the temperature measured by the aquastat to I changed hi limit from 180° to 188° 

I also double checked propane pressure inlet and outlet (12.6” inlet) (9,6” outlet) Good

The second floor hallway thermostat was reading 2° warmer than my temperature probe so I offset up 2° for accuracy. 

Left estimate to properly pipe gas line to propane water heater.
Also left previous estimate to replace air scoop with spirovent air eliminator 

As far as fuel utilizatio
Baby/nursery room got down to 63 last night again.
They are paying $2,500 a month in propane. 650 gallons last few months. 
Boiler size is 204,000 input 170,000 Output 
Square footage is 6000
There’s an additional 700 in basement where there is electric baseboard. 

Nursery room is 14x22=308 sq ft Required BTUs (308x45= 13,860)
25 linear feet of baseboard (25x600 btu per linear ft = 15,000 BTU)
Baseboard is adequate for this room.

I did notice that a pipe clamp thermocouple measured at the supply pipe was a few degrees cooler than the temperature measured by the aquastat to I changed hi limit from 180° to 188° 

I also double checked propane pressure inlet and outlet (12.6” inlet) (9,6” outlet) Good

The second floor hallway thermostat was reading 2° warmer than my temperature probe so I offset up 2° for accuracy. 

Left estimate to properly pipe gas line to propane water heater.
Also left previous estimate to replace air scoop with spirovent air eliminator 

As far as fuel utilizatio
Barry P.
Barry P. Checked in
Baby/nursery room got down to 63 last night again. They are paying $2,500 a month in propane. 650 gallons last few months. Boiler size is 204,000 input 170,000 Output Square footage is 6000 There’s an additional 700 in basement where there is electric baseboard. Nursery room is 14x22=308 sq ft Required BTUs (308x45= 13,860) 25 linear feet of baseboard (25x600 btu per linear ft = 15,000 BTU) Baseboard is adequate for this room. I did notice that a pipe clamp thermocouple measured at the supply pipe was a few degrees cooler than the temperature measured by the aquastat to I changed hi limit from 180° to 188° I also double checked propane pressure inlet and outlet (12.6” inlet) (9,6” outlet) Good The second floor hallway thermostat was reading 2° warmer than my temperature probe so I offset up 2° for accuracy. Left estimate to properly pipe gas line to propane water heater. Also left previous estimate to replace air scoop with spirovent air eliminator As far as fuel utilizatio
Newtown Square, PA 19073
I arrived to the customers home to service their 4 yr old 90% American standard gas furnace system. 
I started with checking the air filter and replaced , the filter size is 16x25x1. I checked all my electrical connections and voltages. I inspected and tested the  burners , flame sensor and the igniter. I water tested all tubing and hoses. I inspected the exhaust and fresh air pipe for restrictions and bellies. I inspected the inducer and the blower motor operation. I checked and tested for combustion and took temp rise splits at the return and the supply. Everything is running good , newer system.
I arrived to the customers home to service their 4 yr old 90% American standard gas furnace system. 
I started with checking the air filter and replaced , the filter size is 16x25x1. I checked all my electrical connections and voltages. I inspected and tested the  burners , flame sensor and the igniter. I water tested all tubing and hoses. I inspected the exhaust and fresh air pipe for restrictions and bellies. I inspected the inducer and the blower motor operation. I checked and tested for combustion and took temp rise splits at the return and the supply. Everything is running good , newer system.
Daniel R.
Daniel R. Checked in
I arrived to the customers home to service their 4 yr old 90% American standard gas furnace system. I started with checking the air filter and replaced , the filter size is 16x25x1. I checked all my electrical connections and voltages. I inspected and tested the burners , flame sensor and the igniter. I water tested all tubing and hoses. I inspected the exhaust and fresh air pipe for restrictions and bellies. I inspected the inducer and the blower motor operation. I checked and tested for combustion and took temp rise splits at the return and the supply. Everything is running good , newer system.
Newtown Square, PA 19073
I arrived to the customers home to perform a Q.A. Inspection on there new 2 stage Trane 95% gas furnace system.  I started with checking the air filter and found good.  the filter size is a aprilaire 413. I checked the overall neatness and performance of the newly installed system. I checked over all system accessories. I checked all my electrical connections and voltages. I inspected and tested the  burners , flame sensor and the igniter. I water tested all tubing and hoses. I inspected the exhaust and fresh air pipe for restrictions and bellies. I inspected the inducer and the blower motor operation. I checked and tested for combustion and temp splits. Everything is in good working order
I arrived to the customers home to perform a Q.A. Inspection on there new 2 stage Trane 95% gas furnace system.  I started with checking the air filter and found good.  the filter size is a aprilaire 413. I checked the overall neatness and performance of the newly installed system. I checked over all system accessories. I checked all my electrical connections and voltages. I inspected and tested the  burners , flame sensor and the igniter. I water tested all tubing and hoses. I inspected the exhaust and fresh air pipe for restrictions and bellies. I inspected the inducer and the blower motor operation. I checked and tested for combustion and temp splits. Everything is in good working order
Daniel R.
Daniel R. Checked in
I arrived to the customers home to perform a Q.A. Inspection on there new 2 stage Trane 95% gas furnace system. I started with checking the air filter and found good. the filter size is a aprilaire 413. I checked the overall neatness and performance of the newly installed system. I checked over all system accessories. I checked all my electrical connections and voltages. I inspected and tested the burners , flame sensor and the igniter. I water tested all tubing and hoses. I inspected the exhaust and fresh air pipe for restrictions and bellies. I inspected the inducer and the blower motor operation. I checked and tested for combustion and temp splits. Everything is in good working order
Newtown Square, PA 19073
Drained 40 gallon hot water heater. Disconnected gas pipe, flu pipe, and 1/2 copper water lines. Put new 40 gallon rheem water heater in place in a pan. Changed out old style gas valve and repipe to new water heater. Cut 1/2 copper lines back to add in two new 3/4 ball valves. Made new copper connections to water heater and added expansion tank. Ran new flue pipe to existing tee. 

Recovered refrigerant from old a/c system. Removed old a/c and furnace. Put new a/c coil and down flow furnace in place. Made metal to adapt to existing return trunk. Sealed air gaps. Connected high and low voltage wiring to new furnace. Removed old style gas valve and replaced with new 1/2 valve. Tested heating stages and gas pressures. Installed new thermostat. 


*Check and adjust charge in warmer weather*
Drained 40 gallon hot water heater. Disconnected gas pipe, flu pipe, and 1/2 copper water lines. Put new 40 gallon rheem water heater in place in a pan. Changed out old style gas valve and repipe to new water heater. Cut 1/2 copper lines back to add in two new 3/4 ball valves. Made new copper connections to water heater and added expansion tank. Ran new flue pipe to existing tee. 

Recovered refrigerant from old a/c system. Removed old a/c and furnace. Put new a/c coil and down flow furnace in place. Made metal to adapt to existing return trunk. Sealed air gaps. Connected high and low voltage wiring to new furnace. Removed old style gas valve and replaced with new 1/2 valve. Tested heating stages and gas pressures. Installed new thermostat. 


*Check and adjust charge in warmer weather*
Riley V.
Riley V. Checked in
Drained 40 gallon hot water heater. Disconnected gas pipe, flu pipe, and 1/2 copper water lines. Put new 40 gallon rheem water heater in place in a pan. Changed out old style gas valve and repipe to new water heater. Cut 1/2 copper lines back to add in two new 3/4 ball valves. Made new copper connections to water heater and added expansion tank. Ran new flue pipe to existing tee. Recovered refrigerant from old a/c system. Removed old a/c and furnace. Put new a/c coil and down flow furnace in place. Made metal to adapt to existing return trunk. Sealed air gaps. Connected high and low voltage wiring to new furnace. Removed old style gas valve and replaced with new 1/2 valve. Tested heating stages and gas pressures. Installed new thermostat. *Check and adjust charge in warmer weather*
Newtown Square, PA 19073
Drain and removed old water heater. Set new water heater in new 27" drain pan. Adapted hot and cold side piping to new water heater with new expansion tank. Replaced Humidifier saddle valve due to leak. Installed gas piping to new gas valve and leak checked. Adapted smoke pipe to new water heater. Installed water alarm in pan. Need to return to install resideo L1 leak and freeze detector.
Drain and removed old water heater. Set new water heater in new 27" drain pan. Adapted hot and cold side piping to new water heater with new expansion tank. Replaced Humidifier saddle valve due to leak. Installed gas piping to new gas valve and leak checked. Adapted smoke pipe to new water heater. Installed water alarm in pan. Need to return to install resideo L1 leak and freeze detector.
Riley V.
Riley V. Checked in
Drain and removed old water heater. Set new water heater in new 27" drain pan. Adapted hot and cold side piping to new water heater with new expansion tank. Replaced Humidifier saddle valve due to leak. Installed gas piping to new gas valve and leak checked. Adapted smoke pipe to new water heater. Installed water alarm in pan. Need to return to install resideo L1 leak and freeze detector.
Newtown Square, PA 19073
Estimate
Estimate
Diilon M.
Diilon M. Checked in
Estimate
Newtown Square, PA 19073
Quality assurance is complete overall install pretty nice job tested everything checked all the wiring and dip switches. Everything looks to be in order and tested out properly. Do minor adjustments and disabling the alerts equipment. Instructions on top of the ductwork and line insulation not properly secured but the overall job was neat
Quality assurance is complete overall install pretty nice job tested everything checked all the wiring and dip switches. Everything looks to be in order and tested out properly. Do minor adjustments and disabling the alerts equipment. Instructions on top of the ductwork and line insulation not properly secured but the overall job was neat
Nathan P.
Nathan P. Checked in
Quality assurance is complete overall install pretty nice job tested everything checked all the wiring and dip switches. Everything looks to be in order and tested out properly. Do minor adjustments and disabling the alerts equipment. Instructions on top of the ductwork and line insulation not properly secured but the overall job was neat
Newtown Square, PA 19073
Review
Excellent
Mary Ann - Newtown Square, PA 19073
Review
Laura Mertz - Newtown Square, PA 19073
Response from DiBiase Heating and Cooling Company:

Hi Laura! Thank you so much for leaving a 5-star review!

Review
Did a nice job of reviewing options and the potential timeline with the estimate.
Thomas Hardie - Newtown Square, PA 19073
Response from DiBiase Heating and Cooling Company:

Hi Thomas! Thank you for the review! We're glad to hear the estimate process was clear and informative, and that our team took the time to walk you through your options and timeline. If any questions come up as you consider your next steps, don’t hesitate to reach out — we're here to help!

Review
Luis is a credit to DiBiase Plumbing & Heating He is very knowledgeable & explains everything about the HVAC system; makes the customer feel comfortable about their situation. Thank you.
Joanne Mainardi - Newtown Square, PA 19073
Review
Luis Tenorio worked quickly, efficiently, and honestly.
Sha Shafagh - Newtown Square, PA 19073
Response from DiBiase Heating and Cooling Company:

Hi Sha! Thank you for the kind words! We're thrilled to hear that Luis provided fast, efficient, and honest service — that’s exactly the standard we aim for. We’ll be sure to pass along your feedback to him! Thanks again for choosing DiBiase Heating and Cooling!

Review
Riley Vetter and David Rivera got the job done in less time than anticipated. They were professional and courteous.
Heinrich Roder - Newtown Square, PA 19073
Response from DiBiase Heating and Cooling Company:

Hi Heinrich, Thank you for your feedback! We're thrilled Riley and David exceeded expectations with their efficient, professional, and courteous service. We’ll share your kind words with them!

Review
Kurt is always very professional and gets the job done in a timely fashion.
Anne - Newtown Square, PA 19073
Review
Great Service
HY Technology, Inc. - Newtown Square, PA 19073
Review
Kurt is awesome. Efficient and friendly. Competent and knowledgeable
Anne - Newtown Square, PA 19073
Review
Excellent!
Gonzalo - Newtown Square, PA 19073
Review
Excellent
Gonzalo - Newtown Square, PA 19073
Review
Excellent
Gonzalo - Newtown Square, PA 19073
Review
Kurt is friendly and professional. Does a great job.
Anne - Newtown Square, PA 19073
Review
Fantastic
Anne - Newtown Square, PA 19073
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next