610-873-1244 Book Online Text Us

East Fallowfield Township, PA

Expert HVAC Service and More in East Fallowfield Township, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in East Fallowfield Township, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in East Fallowfield Township, PA

Rated 5.0 out of 5 stars based on 12 customer reviews

Customers say: The reviews exhibit a positive overall sentiment, with recurring positive themes and sentiments. The majority of reviews express satisfaction with the services provided, highlighting the expertise, professionalism, and courtesy of the technicians. Customers appreciate the prompt and efficient service, with many mentioning the technicians' ability to diagnose and resolve issues quickly. Positive feedback is also directed towards the company's customer service, with many praising the helpfulness and efficiency of the office staff. Customers also mention the quality of the work and the professionalism of the technicians, indicating a high level of satisfaction with the services provided. Additionally, there are mentions of the technicians' knowledge and expertise, with customers expressing confidence in their ability to handle various HVAC-related issues. Overall, the reviews suggest a positive experience with the company, with customers expressing satisfaction with the services provided and the professionalism of the technicians.

Job Locations and Reviews

Luis 10-17-25 performed gas heat tune up 2018 gas heater 90% trane system. Natural gas. Check all electrical connections and components. Inspect ignition, air delivery and combustion removal systems. Check air flow supply and return air temps ok. Test both zones first and second floor ok. Check blower and cap. Performed combo test ok. I inspect heat exchanger, during inspection found big crack on one of the cells. For safety purposes heater should be repairs as soon as possible. I provided estimate for repairs and recommendations, other option is to get an estimate for new heater. (Heat exchanger is under parts only warranty) other parts out of warranty. I did explain to customer from now on he’s responsible for continuing running the heater under conditions. Customer will get second opinion and will call us if needed. Customer paid one time heat tune up.
Luis 10-17-25 performed gas heat tune up 2018 gas heater 90% trane system. Natural gas. Check all electrical connections and components. Inspect ignition, air delivery and combustion removal systems. Check air flow supply and return air temps ok. Test both zones first and second floor ok. Check blower and cap. Performed combo test ok. I inspect heat exchanger, during inspection found big crack on one of the cells. For safety purposes heater should be repairs as soon as possible. I provided estimate for repairs and recommendations, other option is to get an estimate for new heater. (Heat exchanger is under parts only warranty) other parts out of warranty. I did explain to customer from now on he’s responsible for continuing running the heater under conditions. Customer will get second opinion and will call us if needed. Customer paid one time heat tune up.
Luis T.
Luis T. Checked in
Luis 10-17-25 performed gas heat tune up 2018 gas heater 90% trane system. Natural gas. Check all electrical connections and components. Inspect ignition, air delivery and combustion removal systems. Check air flow supply and return air temps ok. Test both zones first and second floor ok. Check blower and cap. Performed combo test ok. I inspect heat exchanger, during inspection found big crack on one of the cells. For safety purposes heater should be repairs as soon as possible. I provided estimate for repairs and recommendations, other option is to get an estimate for new heater. (Heat exchanger is under parts only warranty) other parts out of warranty. I did explain to customer from now on he’s responsible for continuing running the heater under conditions. Customer will get second opinion and will call us if needed. Customer paid one time heat tune up.
East Fallowfield Township, PA 19320
Luis 10-17-25 performed heat pump inspection of trane variable speed heat pump. Check all electrical connections and components. Replacement of air filter 20x22x1 test back up heat 10 kw ok. Inspect all sensors and inputs/outputs from indoor/outdoor inverter, used Trane tech communication app to test system and check for any error codes, system, shows no issues with zero error codes. Test heat pump operation tee or rise 21 degrees 67/88 compressor amps and voltage ok. Refrigerant levels and pressures within service manufacturer specifications.  Customer currently has heat pump to off position.
Luis 10-17-25 performed heat pump inspection of trane variable speed heat pump. Check all electrical connections and components. Replacement of air filter 20x22x1 test back up heat 10 kw ok. Inspect all sensors and inputs/outputs from indoor/outdoor inverter, used Trane tech communication app to test system and check for any error codes, system, shows no issues with zero error codes. Test heat pump operation tee or rise 21 degrees 67/88 compressor amps and voltage ok. Refrigerant levels and pressures within service manufacturer specifications.  Customer currently has heat pump to off position.
Luis T.
Luis T. Checked in
Luis 10-17-25 performed heat pump inspection of trane variable speed heat pump. Check all electrical connections and components. Replacement of air filter 20x22x1 test back up heat 10 kw ok. Inspect all sensors and inputs/outputs from indoor/outdoor inverter, used Trane tech communication app to test system and check for any error codes, system, shows no issues with zero error codes. Test heat pump operation tee or rise 21 degrees 67/88 compressor amps and voltage ok. Refrigerant levels and pressures within service manufacturer specifications. Customer currently has heat pump to off position.
East Fallowfield Township, PA 19320
I arrived for a hydronic boiler leaking water. When looking at the boiler pressure was sitting at near 20 psi when customer turned the boiler on for me. It did get up and exceeded over 30 psi and started releasing water out of the relief valve into a bucket I did see, a bypass valve was wide open. I did close this would actually feed excess water into the boiler possibly causing more pressure check that seems good. Expansion tank is fine. Oil thing that could be causing back pressure is the domestic tank water tank I did cycle boiler off three or four times it did not exceed 30 psi  Did 20 psi but will once boiler shut down. Will go back to run 18 psi monitor to be sure it still drain into the bucket I collected for my time here for tonight paid by credit card.
I arrived for a hydronic boiler leaking water. When looking at the boiler pressure was sitting at near 20 psi when customer turned the boiler on for me. It did get up and exceeded over 30 psi and started releasing water out of the relief valve into a bucket I did see, a bypass valve was wide open. I did close this would actually feed excess water into the boiler possibly causing more pressure check that seems good. Expansion tank is fine. Oil thing that could be causing back pressure is the domestic tank water tank I did cycle boiler off three or four times it did not exceed 30 psi  Did 20 psi but will once boiler shut down. Will go back to run 18 psi monitor to be sure it still drain into the bucket I collected for my time here for tonight paid by credit card.
Daniel R.
Daniel R. Checked in
I arrived for a hydronic boiler leaking water. When looking at the boiler pressure was sitting at near 20 psi when customer turned the boiler on for me. It did get up and exceeded over 30 psi and started releasing water out of the relief valve into a bucket I did see, a bypass valve was wide open. I did close this would actually feed excess water into the boiler possibly causing more pressure check that seems good. Expansion tank is fine. Oil thing that could be causing back pressure is the domestic tank water tank I did cycle boiler off three or four times it did not exceed 30 psi Did 20 psi but will once boiler shut down. Will go back to run 18 psi monitor to be sure it still drain into the bucket I collected for my time here for tonight paid by credit card.
East Fallowfield Township, PA 19320
Luis 10-10-25 customer called in for no heat coming from the heater. Customer has propane gas heater 90% high efficiency system with a straight air conditioning 4 ton system found thermostat in the off position told customer to turn the thermostat to heat so I can check the operation. I noticed that the motor for inducer assembly would not run found water inside exhaust motor Removed inducer assembly and drain it, check drain system, and test operation. System came on. I perform a safety test combustion test. I see that the air cabinet does not have any filter. I would recommend installing a new filter. Customer will install filter. During visit, I also informed customer about surge protection and water, protect protection. Customer has air scrubber light is off. I also noticed air scrubber consuming 50% of the power from the heater. Separate Transformer should be used. I emailed estimates
Luis 10-10-25 customer called in for no heat coming from the heater. Customer has propane gas heater 90% high efficiency system with a straight air conditioning 4 ton system found thermostat in the off position told customer to turn the thermostat to heat so I can check the operation. I noticed that the motor for inducer assembly would not run found water inside exhaust motor Removed inducer assembly and drain it, check drain system, and test operation. System came on. I perform a safety test combustion test. I see that the air cabinet does not have any filter. I would recommend installing a new filter. Customer will install filter. During visit, I also informed customer about surge protection and water, protect protection. Customer has air scrubber light is off. I also noticed air scrubber consuming 50% of the power from the heater. Separate Transformer should be used. I emailed estimates
Luis T.
Luis T. Checked in
Luis 10-10-25 customer called in for no heat coming from the heater. Customer has propane gas heater 90% high efficiency system with a straight air conditioning 4 ton system found thermostat in the off position told customer to turn the thermostat to heat so I can check the operation. I noticed that the motor for inducer assembly would not run found water inside exhaust motor Removed inducer assembly and drain it, check drain system, and test operation. System came on. I perform a safety test combustion test. I see that the air cabinet does not have any filter. I would recommend installing a new filter. Customer will install filter. During visit, I also informed customer about surge protection and water, protect protection. Customer has air scrubber light is off. I also noticed air scrubber consuming 50% of the power from the heater. Separate Transformer should be used. I emailed estimates
East Fallowfield Township, PA 19320
Reviewed job with Dillon to determine best options regarding zoning.  House is zoned with 3 zones , 1st floor, 2nd floor and sunroom.
Reviewed job with Dillon to determine best options regarding zoning.  House is zoned with 3 zones , 1st floor, 2nd floor and sunroom.
Joseph D.
Joseph D. Checked in
Reviewed job with Dillon to determine best options regarding zoning. House is zoned with 3 zones , 1st floor, 2nd floor and sunroom.
East Fallowfield Township, PA 19320
Performed precision a/c tune up on 17 year old trane a/c system. Replaced 16x20x1 air filter. Checked temperature split. Found no water or surge protection on system, provided estimates. Checked r-22 pressures, system is slightly low , would recommend get a quote from our office for replacement of the a/c. Also found burnt and pitted contacter. , provided estimate to replace contacter. Tested outdoor capacitor. A/c is working at time of service.
Performed precision a/c tune up on 17 year old trane a/c system. Replaced 16x20x1 air filter. Checked temperature split. Found no water or surge protection on system, provided estimates. Checked r-22 pressures, system is slightly low , would recommend get a quote from our office for replacement of the a/c. Also found burnt and pitted contacter. , provided estimate to replace contacter. Tested outdoor capacitor. A/c is working at time of service.
Kurt  M.
Kurt M. Checked in
Performed precision a/c tune up on 17 year old trane a/c system. Replaced 16x20x1 air filter. Checked temperature split. Found no water or surge protection on system, provided estimates. Checked r-22 pressures, system is slightly low , would recommend get a quote from our office for replacement of the a/c. Also found burnt and pitted contacter. , provided estimate to replace contacter. Tested outdoor capacitor. A/c is working at time of service.
East Fallowfield Township, PA 19320
Completed (2) Heat tune ups

Minisplit with (4) indoor heads.
Cleaned all washable filters. All very dirty.
Set each remote for heating demand. And tested wiring, amp draw, and Tempe rise.
Verified refrigerant pressure.
Left email estimate for power monitoring system which is a more comprehensible protection for the Minisplit than the existing surge protector. 

3 Ton Heat pump with 15KW electric heat kit:
Replaced 16x25x1 filter.
Inspected wiring, controls, electric motors. There are no surge protection devices. Capacitor and contactor very worn. Left estimate to replace contactor and install heavy duty capacitor. 64A 15KW @ 240V
Inspected drain. There are no water safeties pump is has long discharge time. Left estimate for drain system upgrades.
Measured temperature rise
Checked refrigerant charge/pressures. 

Also provided comprehensive PremiumPlus estimate which includes 80% rebuild of outdoor unit and drain system enhancement and safeties on indoor unit. She is not interested in a
Completed (2) Heat tune ups

Minisplit with (4) indoor heads.
Cleaned all washable filters. All very dirty.
Set each remote for heating demand. And tested wiring, amp draw, and Tempe rise.
Verified refrigerant pressure.
Left email estimate for power monitoring system which is a more comprehensible protection for the Minisplit than the existing surge protector. 

3 Ton Heat pump with 15KW electric heat kit:
Replaced 16x25x1 filter.
Inspected wiring, controls, electric motors. There are no surge protection devices. Capacitor and contactor very worn. Left estimate to replace contactor and install heavy duty capacitor. 64A 15KW @ 240V
Inspected drain. There are no water safeties pump is has long discharge time. Left estimate for drain system upgrades.
Measured temperature rise
Checked refrigerant charge/pressures. 

Also provided comprehensive PremiumPlus estimate which includes 80% rebuild of outdoor unit and drain system enhancement and safeties on indoor unit. She is not interested in a
Barry P.
Barry P. Checked in
Completed (2) Heat tune ups Minisplit with (4) indoor heads. Cleaned all washable filters. All very dirty. Set each remote for heating demand. And tested wiring, amp draw, and Tempe rise. Verified refrigerant pressure. Left email estimate for power monitoring system which is a more comprehensible protection for the Minisplit than the existing surge protector. 3 Ton Heat pump with 15KW electric heat kit: Replaced 16x25x1 filter. Inspected wiring, controls, electric motors. There are no surge protection devices. Capacitor and contactor very worn. Left estimate to replace contactor and install heavy duty capacitor. 64A 15KW @ 240V Inspected drain. There are no water safeties pump is has long discharge time. Left estimate for drain system upgrades. Measured temperature rise Checked refrigerant charge/pressures. Also provided comprehensive PremiumPlus estimate which includes 80% rebuild of outdoor unit and drain system enhancement and safeties on indoor unit. She is not interested in a
East Fallowfield Township, PA 19320
Review
Barry was very thorough. He found an issue we were not aware of and though he had already been here a couple hours services our heating system, he reached out to his supply department to ensure they had parts in stock. He then left to pick up those parts, came back and installed them. Talk about taking care of the customer. Barry is awesome at customer service.
J - East Fallowfield Township, PA 19320
Completed Oil Heat tune up:

Bosch heat pump inverter W
Spirit low-boy oil furnace 105,000 BTU

Cleaned washable filters. Vacuumed. Not terribly dirty.
Cleaned flues and heat exchanger, very little soot or debris 
New GarBer Spin on oil filter, strainer is clean, new .75 80°A nozzle.
Inspected cad cell eye, electrodes, air band and shutter, tiger loop.
Verified pump pressure 
Inspected wiring, controls, electric motors and components. Set post-run time for burner to 30 seconds @ primary control 
Measured temperature rise.

Smoke, draft and combustion tests: Pass

Water heater T+P valve is piped facing up. This is a safety hazard. Needs to be piped to the floor. Left estimate to address this. Pipe it correctly in copper to the floor. 

Left estimate for single UV light to be installed directly over 

Oil furnace operating well at this time 
Repipe T+P valve piping to floor
Completed Oil Heat tune up:

Bosch heat pump inverter W
Spirit low-boy oil furnace 105,000 BTU

Cleaned washable filters. Vacuumed. Not terribly dirty.
Cleaned flues and heat exchanger, very little soot or debris 
New GarBer Spin on oil filter, strainer is clean, new .75 80°A nozzle.
Inspected cad cell eye, electrodes, air band and shutter, tiger loop.
Verified pump pressure 
Inspected wiring, controls, electric motors and components. Set post-run time for burner to 30 seconds @ primary control 
Measured temperature rise.

Smoke, draft and combustion tests: Pass

Water heater T+P valve is piped facing up. This is a safety hazard. Needs to be piped to the floor. Left estimate to address this. Pipe it correctly in copper to the floor. 

Left estimate for single UV light to be installed directly over 

Oil furnace operating well at this time 
Repipe T+P valve piping to floor
Barry P.
Barry P. Checked in
Completed Oil Heat tune up: Bosch heat pump inverter W Spirit low-boy oil furnace 105,000 BTU Cleaned washable filters. Vacuumed. Not terribly dirty. Cleaned flues and heat exchanger, very little soot or debris New GarBer Spin on oil filter, strainer is clean, new .75 80°A nozzle. Inspected cad cell eye, electrodes, air band and shutter, tiger loop. Verified pump pressure Inspected wiring, controls, electric motors and components. Set post-run time for burner to 30 seconds @ primary control Measured temperature rise. Smoke, draft and combustion tests: Pass Water heater T+P valve is piped facing up. This is a safety hazard. Needs to be piped to the floor. Left estimate to address this. Pipe it correctly in copper to the floor. Left estimate for single UV light to be installed directly over Oil furnace operating well at this time Repipe T+P valve piping to floor
East Fallowfield Township, PA 19320
*Created new call to complete work as agreed to in previous invoice/appointment from earlier today.

Cut out improperly installed T+P relief valve piping and installed new. 
Pipe is now in copper 3-5” from floor.

*Very important: I informed homeowners that they have a spin-on oil filter and that in future oil tune up visits there will be an additional charge for this filter. Approximately $80-$120. 

Collected payment today.
*Created new call to complete work as agreed to in previous invoice/appointment from earlier today.

Cut out improperly installed T+P relief valve piping and installed new. 
Pipe is now in copper 3-5” from floor.

*Very important: I informed homeowners that they have a spin-on oil filter and that in future oil tune up visits there will be an additional charge for this filter. Approximately $80-$120. 

Collected payment today.
Barry P.
Barry P. Checked in
*Created new call to complete work as agreed to in previous invoice/appointment from earlier today. Cut out improperly installed T+P relief valve piping and installed new. Pipe is now in copper 3-5” from floor. *Very important: I informed homeowners that they have a spin-on oil filter and that in future oil tune up visits there will be an additional charge for this filter. Approximately $80-$120. Collected payment today.
East Fallowfield Township, PA 19320
Completed
QA

Inspected all aspects of install.

There was a return duct popping when you walk over a section on first floor sun room. I secured the return trunk a little better. Popping went away.

Condensate pump was loud. Installed Asurity clearvue pump.

Checked fan speeds.

High sensitivity gas leak test on furnace piping: Pass

Combustion test: Pass
Completed
QA

Inspected all aspects of install.

There was a return duct popping when you walk over a section on first floor sun room. I secured the return trunk a little better. Popping went away.

Condensate pump was loud. Installed Asurity clearvue pump.

Checked fan speeds.

High sensitivity gas leak test on furnace piping: Pass

Combustion test: Pass
Barry P.
Barry P. Checked in
Completed QA Inspected all aspects of install. There was a return duct popping when you walk over a section on first floor sun room. I secured the return trunk a little better. Popping went away. Condensate pump was loud. Installed Asurity clearvue pump. Checked fan speeds. High sensitivity gas leak test on furnace piping: Pass Combustion test: Pass
East Fallowfield Township, PA 19320
Review
Luis is the best! I trust him and his work. He is excellent. I am always happy with the work provided by DiBiase
Maura - East Fallowfield Township, PA 19320
Review
Extremely informative and you can tell Kurt (Technician) really loved his field of work. He was extremely pationiate towards educating and ensuring any heating/cooling problems were resolved in the most efficent manner.
Jonathan Muntz - East Fallowfield Township, PA 19320
Response from DiBiase Heating and Cooling Company:

Hi Jonathan! Thank you so much for your kind words! We're thrilled to hear that Kurt made such a great impression. His passion for the trade and commitment to helping our customers truly sets him apart. We'll be sure to pass along your feedback—it will mean a lot to him. If there's ever anything else we can help with, don’t hesitate to reach out!

Review
DiBiase heating and cooling is a company I will definitely call again when I experience HVAC issues. From the moment I contacted DiBiase, the staff was attentive and helpful. I received the option to call or text with details which was convenient with my full schedule. I received a text when the technician was on his way, along with the ability to track his arrival time! The technician who came to my home, Luis Tenorio was courteous, professional, and competent. Luis explained the furnace system to me in a way that I understood and shared details about his process of diagnosing the problem. My heating issue was resolved. I am very pleased with the services. I would highly recommend DiBiase Heating and Cooling.
Suzette - East Fallowfield Township, PA 19320
Review
Does an excellent job. Explains everything clearly. No surprises
Maura - East Fallowfield Township, PA 19320
Response from DiBiase Heating and Cooling Company:

We’re delighted to hear about your recent experience with us and we’re so pleased that you recommend our services. Thank you for taking the time to share your experience and we look forward to welcoming you back soon!

Review
Great service!
Leigh - East Fallowfield Township, PA 19320
Response from DiBiase Heating and Cooling Company:

Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.

Review
Always great service from DiBiase!
Freddy Alvisi - East Fallowfield Township, PA 19320
Response from DiBiase Heating and Cooling Company:

Hi Freddy! Thank you for your continued trust in DiBiase Heating and Cooling! We’re glad to hear you’ve consistently had great service. We look forward to serving you again!

Review
Luis does an excellent job! He is personable, wants to make sure I am happy with the service, explains everything and goes the extra mile.
Maura - East Fallowfield Township, PA 19320
Review
Tom, our service representative, was very thorough with his work, offered some suggestions, and very friendly to deal with. Knows his HVAC!
David - East Fallowfield Township, PA 19320
Review
Service
Kristen - East Fallowfield Township, PA 19320
Review
The technician was very knowledgeable and informative regarding the care and maintenance of my HVAC system.
Thomas - East Fallowfield Township, PA 19320
Review
Thomas Velez was our most recent technician and he was great. He was on-time, took time to explain what he was doing, and went the extra mile to help me set up the app for our water heater. Thanks again, DiBiase!
Amy - East Fallowfield Township, PA 19320
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next