610-873-1244 Book Online Text Us

East Fallowfield Township, PA

Expert HVAC Service and More in East Fallowfield Township, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in East Fallowfield Township, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in East Fallowfield Township, PA

Rated 5.0 out of 5 stars based on 13 customer reviews

Customers say: The reviews exhibit a positive overall sentiment, with recurring positive themes and sentiments. The majority of reviews express satisfaction with the services provided, highlighting the expertise, professionalism, and courtesy of the technicians. Customers appreciate the prompt and efficient service, with many mentioning the technicians' ability to diagnose and resolve issues quickly. Positive feedback is also directed towards the company's customer service, with many praising the helpfulness and efficiency of the office staff. Customers also mention the quality of the work and the professionalism of the technicians, indicating a high level of satisfaction with the services provided. Additionally, there are mentions of the technicians' knowledge and expertise, with customers expressing confidence in their ability to handle various HVAC-related issues. Overall, the reviews suggest a positive experience with the company, with customers expressing satisfaction with the services provided and the professionalism of the technicians.

Our Local Reviews by City

Job Locations and Reviews


The valve on oil tank is a fire omatic valve that is stuck OPEN. Tried multiple times to close valve.
Filter and strainer cannot be replaced until new valve is installed.
We will provide email estimate to pull tank into vacuum and install new valve.
Tank is 50 years old so you the other option is to replace the oil tank altogether with new valve. 

Completed remainder of tune up procedures.
Replaced 16x25x1 air filter 
Cleaned heat exchanger. Only minimal soot and some rust in heat exchanger.
Inspected all burner components. Cad cell eye is glazed over. Provided email estimate to replace. 
Nozzle is .50 80A or what is currently in there is Steinen. 50 80 HT.
Measured temperature rise

Combustion and draft tests pass.

Open return. For this applications there must be return ducts ducted to appliance from the living space. As it is, the return air will influence the draft and combustion of the furnace.

System operating ok but needs new oil tank or at very least new tank valve.

The valve on oil tank is a fire omatic valve that is stuck OPEN. Tried multiple times to close valve.
Filter and strainer cannot be replaced until new valve is installed.
We will provide email estimate to pull tank into vacuum and install new valve.
Tank is 50 years old so you the other option is to replace the oil tank altogether with new valve. 

Completed remainder of tune up procedures.
Replaced 16x25x1 air filter 
Cleaned heat exchanger. Only minimal soot and some rust in heat exchanger.
Inspected all burner components. Cad cell eye is glazed over. Provided email estimate to replace. 
Nozzle is .50 80A or what is currently in there is Steinen. 50 80 HT.
Measured temperature rise

Combustion and draft tests pass.

Open return. For this applications there must be return ducts ducted to appliance from the living space. As it is, the return air will influence the draft and combustion of the furnace.

System operating ok but needs new oil tank or at very least new tank valve.
Barry P.
Barry P. Checked in
The valve on oil tank is a fire omatic valve that is stuck OPEN. Tried multiple times to close valve. Filter and strainer cannot be replaced until new valve is installed. We will provide email estimate to pull tank into vacuum and install new valve. Tank is 50 years old so you the other option is to replace the oil tank altogether with new valve. Completed remainder of tune up procedures. Replaced 16x25x1 air filter Cleaned heat exchanger. Only minimal soot and some rust in heat exchanger. Inspected all burner components. Cad cell eye is glazed over. Provided email estimate to replace. Nozzle is .50 80A or what is currently in there is Steinen. 50 80 HT. Measured temperature rise Combustion and draft tests pass. Open return. For this applications there must be return ducts ducted to appliance from the living space. As it is, the return air will influence the draft and combustion of the furnace. System operating ok but needs new oil tank or at very least new tank valve.
East Fallowfield Township, PA 19320

Completed heat tune up for natural gas furnace.

Homeowners will replace 20x25x4 filter soon
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses.
Propane burners are very corroded. There have already been no heat issues caused by burners back to 2023. Burners are worse now. I removed buildup of rust from crossover ports. Strongly recommend upgrading burners to stainless steel. 
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked wiring, controls, electric motors and components; there are no surge protectors; left estimate for a surge protector for each of the 2 main circuits of system
Checked manifold gas pressure; there is an appliance connector inside furnace compartment. Needs to be hard piped. Provided previous estimate to repair. 
Inspected drain and pump. 

Combustion, draft and smoke tests: Pass

After discussing with Mr. Seaman h

Completed heat tune up for natural gas furnace.

Homeowners will replace 20x25x4 filter soon
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses.
Propane burners are very corroded. There have already been no heat issues caused by burners back to 2023. Burners are worse now. I removed buildup of rust from crossover ports. Strongly recommend upgrading burners to stainless steel. 
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked wiring, controls, electric motors and components; there are no surge protectors; left estimate for a surge protector for each of the 2 main circuits of system
Checked manifold gas pressure; there is an appliance connector inside furnace compartment. Needs to be hard piped. Provided previous estimate to repair. 
Inspected drain and pump. 

Combustion, draft and smoke tests: Pass

After discussing with Mr. Seaman h
Barry P.
Barry P. Checked in
Completed heat tune up for natural gas furnace. Homeowners will replace 20x25x4 filter soon Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses. Propane burners are very corroded. There have already been no heat issues caused by burners back to 2023. Burners are worse now. I removed buildup of rust from crossover ports. Strongly recommend upgrading burners to stainless steel. Inspected hot surface ignitor and verified resistance with meter Cleaned flame sensor and verified flame rectification circuit Measured temperature rise and static pressure Checked wiring, controls, electric motors and components; there are no surge protectors; left estimate for a surge protector for each of the 2 main circuits of system Checked manifold gas pressure; there is an appliance connector inside furnace compartment. Needs to be hard piped. Provided previous estimate to repair. Inspected drain and pump. Combustion, draft and smoke tests: Pass After discussing with Mr. Seaman h
East Fallowfield Township, PA 19320
Performed quality assurance check. Tested unit operation and checked all the DIP switch settings along with the quality of work done regarding the install system to manufacture specifications at this time. The unit needed to be cleaned up again inside. I collected check
Performed quality assurance check. Tested unit operation and checked all the DIP switch settings along with the quality of work done regarding the install system to manufacture specifications at this time. The unit needed to be cleaned up again inside. I collected check
Nathan P.
Nathan P. Checked in
Performed quality assurance check. Tested unit operation and checked all the DIP switch settings along with the quality of work done regarding the install system to manufacture specifications at this time. The unit needed to be cleaned up again inside. I collected check
East Fallowfield Township, PA 19320
Quality assurance check all dip switches,tested system analyzed the install quality of work, operation system is currently running . customers happy with the work .schrader valve caps on the outdoor unit were loose unit needed to be cleaned up inside, and switches needed to be adjusted.
Quality assurance check all dip switches,tested system analyzed the install quality of work, operation system is currently running . customers happy with the work .schrader valve caps on the outdoor unit were loose unit needed to be cleaned up inside, and switches needed to be adjusted.
Nathan P.
Nathan P. Checked in
Quality assurance check all dip switches,tested system analyzed the install quality of work, operation system is currently running . customers happy with the work .schrader valve caps on the outdoor unit were loose unit needed to be cleaned up inside, and switches needed to be adjusted.
East Fallowfield Township, PA 19320
Performed precision heat tune up on trane heat pump system. Homeowner replaces 14x25x1 air filter. Checked all electrical connections and components. Checked temperature rise. Found only 14-2 power wire feeding 5 kw in air handler. Power wire should be a 10-2 with a 30 amp double pole breaker. Also found aqua guard water detection switch in pa recommend upgrading to wet switch. Inspected evaporation coil. Tested outdoor capacitor. Checked 410a refrigerant pressures. Provided estimate to install surge protector on mini split system. Found a spot inside condenser coil where aluminum fins were ripped off possibly because of an I’ve chunk in side. No damage to pipping inside though. Did not heat any loud cluck from heat pump while on site. Heat pump is working properly at time of service.
Performed precision heat tune up on trane heat pump system. Homeowner replaces 14x25x1 air filter. Checked all electrical connections and components. Checked temperature rise. Found only 14-2 power wire feeding 5 kw in air handler. Power wire should be a 10-2 with a 30 amp double pole breaker. Also found aqua guard water detection switch in pa recommend upgrading to wet switch. Inspected evaporation coil. Tested outdoor capacitor. Checked 410a refrigerant pressures. Provided estimate to install surge protector on mini split system. Found a spot inside condenser coil where aluminum fins were ripped off possibly because of an I’ve chunk in side. No damage to pipping inside though. Did not heat any loud cluck from heat pump while on site. Heat pump is working properly at time of service.
Kurt  M.
Kurt M. Checked in
Performed precision heat tune up on trane heat pump system. Homeowner replaces 14x25x1 air filter. Checked all electrical connections and components. Checked temperature rise. Found only 14-2 power wire feeding 5 kw in air handler. Power wire should be a 10-2 with a 30 amp double pole breaker. Also found aqua guard water detection switch in pa recommend upgrading to wet switch. Inspected evaporation coil. Tested outdoor capacitor. Checked 410a refrigerant pressures. Provided estimate to install surge protector on mini split system. Found a spot inside condenser coil where aluminum fins were ripped off possibly because of an I’ve chunk in side. No damage to pipping inside though. Did not heat any loud cluck from heat pump while on site. Heat pump is working properly at time of service.
East Fallowfield Township, PA 19320
Luis 12-5-25 gas heat tune up 


Inspected burners, heat exchanger, pressure switches and inducer assembly
Cleaned flame sensor and verified flame rectification circuit
Inspected ignitor and clean sensor 
Confirmed proper manifold gas pressures
Measured temperature rise ok  and check static pressure
 checked drain
Inspected wiring, controls, electric motors and components;  no surge protection customer is aware no surge protection, performed Combustion and draft tests

System operating well at this time

Homeowner paid for plan renewal today.
Luis 12-5-25 gas heat tune up 


Inspected burners, heat exchanger, pressure switches and inducer assembly
Cleaned flame sensor and verified flame rectification circuit
Inspected ignitor and clean sensor 
Confirmed proper manifold gas pressures
Measured temperature rise ok  and check static pressure
 checked drain
Inspected wiring, controls, electric motors and components;  no surge protection customer is aware no surge protection, performed Combustion and draft tests

System operating well at this time

Homeowner paid for plan renewal today.
Luis T.
Luis T. Checked in
Luis 12-5-25 gas heat tune up Inspected burners, heat exchanger, pressure switches and inducer assembly Cleaned flame sensor and verified flame rectification circuit Inspected ignitor and clean sensor Confirmed proper manifold gas pressures Measured temperature rise ok and check static pressure checked drain Inspected wiring, controls, electric motors and components; no surge protection customer is aware no surge protection, performed Combustion and draft tests System operating well at this time Homeowner paid for plan renewal today.
East Fallowfield Township, PA 19320
Luis 12-3-25 customer has a Rheem tankless water heater propane. It does not fire all the time code 11 I check venting, inlet gas pressures. Propane, gas pressure coming in as 11 inches water column. I will probably increase that about 13 inches water column. Also, I will recommend getting rid of the concentric kit and run 3 inch venting to the outside for intake and exhaust. Customer will take care of those tasks. If customers still has issues, further troubleshooting will be required. Office to decide if we work on this type of equipment.
Luis 12-3-25 customer has a Rheem tankless water heater propane. It does not fire all the time code 11 I check venting, inlet gas pressures. Propane, gas pressure coming in as 11 inches water column. I will probably increase that about 13 inches water column. Also, I will recommend getting rid of the concentric kit and run 3 inch venting to the outside for intake and exhaust. Customer will take care of those tasks. If customers still has issues, further troubleshooting will be required. Office to decide if we work on this type of equipment.
Luis T.
Luis T. Checked in
Luis 12-3-25 customer has a Rheem tankless water heater propane. It does not fire all the time code 11 I check venting, inlet gas pressures. Propane, gas pressure coming in as 11 inches water column. I will probably increase that about 13 inches water column. Also, I will recommend getting rid of the concentric kit and run 3 inch venting to the outside for intake and exhaust. Customer will take care of those tasks. If customers still has issues, further troubleshooting will be required. Office to decide if we work on this type of equipment.
East Fallowfield Township, PA 19320
Daniel R.
Daniel R. Checked in
I arrived to the customers home for a water leak on the furnace. The threads on the bar fitting coming out of furnace into the PVC was loose not very tight. The system is about five years old. I remove the fitting put some Teflon tape on it and tightened back into the PVC water tested the system no water at this time. I collected for $164.52 paid by cc.
East Fallowfield Township, PA 19320
Installed new trane gas furnace and A/C coil. Built new return and supply. Tapped/caulked return and supply. Adapted high volt and installed new outlet and switch. Adapted gas line and flue pipes. Ran new condensate line with ez trap and condensate pump. Ran new vinyl from condensate pump to sump pump located in basement. Installed new t6 thermostat and wired low volt with safeties. Ran new line set and connected to new equipment. Installed new A/C outdoor on leveled pad. Installed new disconnect with surge protector and wired into outdoor unit. Cleaned up work are and tested our equipment. To come to test AC.
Installed new trane gas furnace and A/C coil. Built new return and supply. Tapped/caulked return and supply. Adapted high volt and installed new outlet and switch. Adapted gas line and flue pipes. Ran new condensate line with ez trap and condensate pump. Ran new vinyl from condensate pump to sump pump located in basement. Installed new t6 thermostat and wired low volt with safeties. Ran new line set and connected to new equipment. Installed new A/C outdoor on leveled pad. Installed new disconnect with surge protector and wired into outdoor unit. Cleaned up work are and tested our equipment. To come to test AC.
Zachary  B.
Zachary B. Checked in
Installed new trane gas furnace and A/C coil. Built new return and supply. Tapped/caulked return and supply. Adapted high volt and installed new outlet and switch. Adapted gas line and flue pipes. Ran new condensate line with ez trap and condensate pump. Ran new vinyl from condensate pump to sump pump located in basement. Installed new t6 thermostat and wired low volt with safeties. Ran new line set and connected to new equipment. Installed new A/C outdoor on leveled pad. Installed new disconnect with surge protector and wired into outdoor unit. Cleaned up work are and tested our equipment. To come to test AC.
East Fallowfield Township, PA 19320
Nathan P.
Nathan P. Checked in
.
East Fallowfield Township, PA 19320
Review
Another great visit by the famous Luis! He keeps my systems running like fine-tuned clocks!
Neal Baldwin - East Fallowfield Township, PA 19320
Review
Barry was very thorough. He found an issue we were not aware of and though he had already been here a couple hours services our heating system, he reached out to his supply department to ensure they had parts in stock. He then left to pick up those parts, came back and installed them. Talk about taking care of the customer. Barry is awesome at customer service.
J - East Fallowfield Township, PA 19320
Review
Luis is the best! I trust him and his work. He is excellent. I am always happy with the work provided by DiBiase
Maura - East Fallowfield Township, PA 19320
Review
Extremely informative and you can tell Kurt (Technician) really loved his field of work. He was extremely pationiate towards educating and ensuring any heating/cooling problems were resolved in the most efficent manner.
Jonathan Muntz - East Fallowfield Township, PA 19320
Response from DiBiase Heating and Cooling Company:

Hi Jonathan! Thank you so much for your kind words! We're thrilled to hear that Kurt made such a great impression. His passion for the trade and commitment to helping our customers truly sets him apart. We'll be sure to pass along your feedback—it will mean a lot to him. If there's ever anything else we can help with, don’t hesitate to reach out!

Review
DiBiase heating and cooling is a company I will definitely call again when I experience HVAC issues. From the moment I contacted DiBiase, the staff was attentive and helpful. I received the option to call or text with details which was convenient with my full schedule. I received a text when the technician was on his way, along with the ability to track his arrival time! The technician who came to my home, Luis Tenorio was courteous, professional, and competent. Luis explained the furnace system to me in a way that I understood and shared details about his process of diagnosing the problem. My heating issue was resolved. I am very pleased with the services. I would highly recommend DiBiase Heating and Cooling.
Suzette - East Fallowfield Township, PA 19320
Review
Does an excellent job. Explains everything clearly. No surprises
Maura - East Fallowfield Township, PA 19320
Response from DiBiase Heating and Cooling Company:

We’re delighted to hear about your recent experience with us and we’re so pleased that you recommend our services. Thank you for taking the time to share your experience and we look forward to welcoming you back soon!

Review
Great service!
Leigh - East Fallowfield Township, PA 19320
Response from DiBiase Heating and Cooling Company:

Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.

Review
Always great service from DiBiase!
Freddy Alvisi - East Fallowfield Township, PA 19320
Response from DiBiase Heating and Cooling Company:

Hi Freddy! Thank you for your continued trust in DiBiase Heating and Cooling! We’re glad to hear you’ve consistently had great service. We look forward to serving you again!

Review
Luis does an excellent job! He is personable, wants to make sure I am happy with the service, explains everything and goes the extra mile.
Maura - East Fallowfield Township, PA 19320
Review
Tom, our service representative, was very thorough with his work, offered some suggestions, and very friendly to deal with. Knows his HVAC!
David - East Fallowfield Township, PA 19320
Review
Service
Kristen - East Fallowfield Township, PA 19320
Review
The technician was very knowledgeable and informative regarding the care and maintenance of my HVAC system.
Thomas - East Fallowfield Township, PA 19320
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next