610-873-1244 Book Online Text Us

Glenolden, PA

Expert HVAC Service and More in Glenolden, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Glenolden, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in Glenolden, PA

Rated 5.0 out of 5 stars based on 1 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently express gratitude for professional, knowledgeable, and courteous technicians who demonstrate expertise in diagnosing and resolving HVAC issues efficiently. A recurring theme is the technicians' ability to clearly explain problems and solutions, making customers feel informed and comfortable throughout the service process. Many reviewers emphasize the thoroughness and attention to detail displayed during installations, repairs, and routine maintenance, with several noting how technicians go above and beyond expectations. The prompt response times, particularly for emergency calls, receive frequent praise, as does the professionalism and respectful demeanor of service personnel. Customers repeatedly express confidence in the quality of work performed and indicate strong willingness to recommend the company to others. The positive tone extends to appreciation for warranty reminders and cost-saving suggestions that demonstrate customer-focused service. Overall, the reviews convey a sense of relief, satisfaction, and trust in the company's ability to deliver reliable, high-quality HVAC services with exceptional customer care.

Our Local Reviews by City

Job Locations and Reviews

Reviewed equipment with Michelle to inspect installation.  Installation looks professional and there were no issues.  Found air filter to be getting dirty, informed Michelle to replace 16x25x1 filter as soon as possible.  Tested system in ac mode and measured system charge and tested all components operation.  Measured supply air temp.  Michelle said 2nd floor is hotter than the first floor and this was a problem before the installation.  Inspected ductwork and found 2 return grills on the second floor that were abandoned when a wall was removed in the kitchen.  There are currently no return air ducts on the second floor and this is why it is hotter.  Found a path in dining room corner that aligns with 2nd floor bedroom and mechanical room where a return can go.  Michelle will weight out the cost of getting a contractor to put in a soffit.  Inspected wiring that was completed by electrician.  Taped connections at outdoor unit and reinserted surge protector wiring into the disconnect te
Reviewed equipment with Michelle to inspect installation.  Installation looks professional and there were no issues.  Found air filter to be getting dirty, informed Michelle to replace 16x25x1 filter as soon as possible.  Tested system in ac mode and measured system charge and tested all components operation.  Measured supply air temp.  Michelle said 2nd floor is hotter than the first floor and this was a problem before the installation.  Inspected ductwork and found 2 return grills on the second floor that were abandoned when a wall was removed in the kitchen.  There are currently no return air ducts on the second floor and this is why it is hotter.  Found a path in dining room corner that aligns with 2nd floor bedroom and mechanical room where a return can go.  Michelle will weight out the cost of getting a contractor to put in a soffit.  Inspected wiring that was completed by electrician.  Taped connections at outdoor unit and reinserted surge protector wiring into the disconnect te
Joseph D.
Joseph D. Checked in
Reviewed equipment with Michelle to inspect installation. Installation looks professional and there were no issues. Found air filter to be getting dirty, informed Michelle to replace 16x25x1 filter as soon as possible. Tested system in ac mode and measured system charge and tested all components operation. Measured supply air temp. Michelle said 2nd floor is hotter than the first floor and this was a problem before the installation. Inspected ductwork and found 2 return grills on the second floor that were abandoned when a wall was removed in the kitchen. There are currently no return air ducts on the second floor and this is why it is hotter. Found a path in dining room corner that aligns with 2nd floor bedroom and mechanical room where a return can go. Michelle will weight out the cost of getting a contractor to put in a soffit. Inspected wiring that was completed by electrician. Taped connections at outdoor unit and reinserted surge protector wiring into the disconnect te
Glenolden, PA 19036
Estomate
Estomate
Tony F.
Tony F. Checked in
Estomate
Glenolden, PA 19036
Luis 5-10-26 customer called Joe, they have an issue with the electrical panel, upon arrival check outdoor ac  breaker and found to be damaged visually inspect panel, I was not able to install new breaker due bud bars been damaged. Customer needs to contact electrician to inspect electrical panel, most likely customer will need to upgrade electrical panel for safety purposes.
Luis 5-10-26 customer called Joe, they have an issue with the electrical panel, upon arrival check outdoor ac  breaker and found to be damaged visually inspect panel, I was not able to install new breaker due bud bars been damaged. Customer needs to contact electrician to inspect electrical panel, most likely customer will need to upgrade electrical panel for safety purposes.
Luis T.
Luis T. Checked in
Luis 5-10-26 customer called Joe, they have an issue with the electrical panel, upon arrival check outdoor ac breaker and found to be damaged visually inspect panel, I was not able to install new breaker due bud bars been damaged. Customer needs to contact electrician to inspect electrical panel, most likely customer will need to upgrade electrical panel for safety purposes.
Glenolden, PA 19036
Replaced txv pressure tested evacuated and charged system to standards with fresh refrigerant. Tested operations . Supply at 49.
Replaced txv pressure tested evacuated and charged system to standards with fresh refrigerant. Tested operations . Supply at 49.
Nathan P.
Nathan P. Checked in
Replaced txv pressure tested evacuated and charged system to standards with fresh refrigerant. Tested operations . Supply at 49.
Glenolden, PA 19036
Luis 12-8-25 performed quality assurance on recently installed system. Check indoor and outdoor units. All electrical connections and components ok. Check heater operation settings on second stage delay ok CFM on heat and ac side ok. Test safeties ok. Check static pressure. Rerun side is very high in can be improve by adding different type of grill (floor metal grill and making the opening bigger). See photos. We can also increase return flexes to 8 currently 7 in (2). I also replaced filter. Customer will set up WiFi later on. I showed customer how to operate Settings on thermostat. Customer also would want to move unit coupe feet away from door see photos. Joe is aware this.
Luis 12-8-25 performed quality assurance on recently installed system. Check indoor and outdoor units. All electrical connections and components ok. Check heater operation settings on second stage delay ok CFM on heat and ac side ok. Test safeties ok. Check static pressure. Rerun side is very high in can be improve by adding different type of grill (floor metal grill and making the opening bigger). See photos. We can also increase return flexes to 8 currently 7 in (2). I also replaced filter. Customer will set up WiFi later on. I showed customer how to operate Settings on thermostat. Customer also would want to move unit coupe feet away from door see photos. Joe is aware this.
Luis T.
Luis T. Checked in
Luis 12-8-25 performed quality assurance on recently installed system. Check indoor and outdoor units. All electrical connections and components ok. Check heater operation settings on second stage delay ok CFM on heat and ac side ok. Test safeties ok. Check static pressure. Rerun side is very high in can be improve by adding different type of grill (floor metal grill and making the opening bigger). See photos. We can also increase return flexes to 8 currently 7 in (2). I also replaced filter. Customer will set up WiFi later on. I showed customer how to operate Settings on thermostat. Customer also would want to move unit coupe feet away from door see photos. Joe is aware this.
Glenolden, PA 19036
SOLD: 11/21/2025 6:02:39 PM - Best
Best system for performance, comfort, and value.
SOLD: 11/21/2025 6:02:39 PM - Best
Best system for performance, comfort, and value.
Riley V.
Riley V. Checked in
SOLD: 11/21/2025 6:02:39 PM - Best Best system for performance, comfort, and value.
Glenolden, PA 19036
Luis 11-17-25 customer called in for no heat, thermostat issues, found unit off upon arrival. Thermostat would not move from 67 up or down. I manually jumper board to test operation, heater did not work until third time. Flames were bouncing as soon as blower come on. I performed combustion test and smoke test, heater filled smoke test, this indicates there is now an opening on heat exchanger, could be welding connections, gaskets or cracks. Unit is from 1992. Customer decided to keep heater off and to get an estimate to replace system. I took photos of indoor and outdoor units. Joe will email Michelle and go over system replacement options.
Luis 11-17-25 customer called in for no heat, thermostat issues, found unit off upon arrival. Thermostat would not move from 67 up or down. I manually jumper board to test operation, heater did not work until third time. Flames were bouncing as soon as blower come on. I performed combustion test and smoke test, heater filled smoke test, this indicates there is now an opening on heat exchanger, could be welding connections, gaskets or cracks. Unit is from 1992. Customer decided to keep heater off and to get an estimate to replace system. I took photos of indoor and outdoor units. Joe will email Michelle and go over system replacement options.
Luis T.
Luis T. Checked in
Luis 11-17-25 customer called in for no heat, thermostat issues, found unit off upon arrival. Thermostat would not move from 67 up or down. I manually jumper board to test operation, heater did not work until third time. Flames were bouncing as soon as blower come on. I performed combustion test and smoke test, heater filled smoke test, this indicates there is now an opening on heat exchanger, could be welding connections, gaskets or cracks. Unit is from 1992. Customer decided to keep heater off and to get an estimate to replace system. I took photos of indoor and outdoor units. Joe will email Michelle and go over system replacement options.
Glenolden, PA 19036

Completed heat tune up for natural gas furnace.

Replaced 16x25x1 folter 
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked wiring, controls, electric motors and components; there are no surge protectors; left estimate for a surge protector for each of the 2 main circuits of system
Checked manifold gas pressure
Inspected drain and pump. There is a condensate pump safety but no EZ trap. A wet switch is recommended to shut down equipment in the event of a water leak on floor provided estimate

Combustion, draft and smoke tests: Pass

Gas furnace is operating well at this time. 

Homeowners renewed and paid for plan today.

Completed heat tune up for natural gas furnace.

Replaced 16x25x1 folter 
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked wiring, controls, electric motors and components; there are no surge protectors; left estimate for a surge protector for each of the 2 main circuits of system
Checked manifold gas pressure
Inspected drain and pump. There is a condensate pump safety but no EZ trap. A wet switch is recommended to shut down equipment in the event of a water leak on floor provided estimate

Combustion, draft and smoke tests: Pass

Gas furnace is operating well at this time. 

Homeowners renewed and paid for plan today.
Barry P.
Barry P. Checked in
Completed heat tune up for natural gas furnace. Replaced 16x25x1 folter Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses Inspected hot surface ignitor and verified resistance with meter Cleaned flame sensor and verified flame rectification circuit Measured temperature rise and static pressure Checked wiring, controls, electric motors and components; there are no surge protectors; left estimate for a surge protector for each of the 2 main circuits of system Checked manifold gas pressure Inspected drain and pump. There is a condensate pump safety but no EZ trap. A wet switch is recommended to shut down equipment in the event of a water leak on floor provided estimate Combustion, draft and smoke tests: Pass Gas furnace is operating well at this time. Homeowners renewed and paid for plan today.
Glenolden, PA 19036
Barry P.
Barry P. Checked in
Completed AC tune up for 2.5 Ton Amana AC system Replaced 16x25x1 filter Indoor and outdoor coils in good condition Inspected wiring, controls, electric motors and components; left estimate for surge protector for indoor equipment Measured temperature split and static pressure Inspected drains; cleared EZ trap, tested pump; added treatment tabs to drain pan. Checked integrity of compressor motor (mega ohm test) Assessed refrigerant charge checked pressures. AC system operating well at this time.
Glenolden, PA 19036
Chris B.
Chris B. Checked in
Performed Precision Heating Tune Up on Amana Gas Furnace. Replaced the Air Filter for system. Inspected electrical components and connections. Cleaned pressure switch tubing. Cleaned flame sensor and inspected burners. Reviewed system programming on the Control Board. Put into operation and performed combustion testing for low and high stage heating. System operating to standards at this time. Collected payment for service plan membership.
Glenolden, PA 19036
Review
Very good service
Donald - Glenolden, PA 19036
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next