Paoli, PA

Expert HVAC Service and More in Paoli, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Paoli, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in Paoli, PA

Rated 4.9 out of 5 stars based on 18 customer reviews

Customers say: The reviews reflect an overwhelmingly positive sentiment toward the HVAC service provided. Customers consistently express appreciation for technicians who are knowledgeable, professional, and efficient in diagnosing and resolving heating issues. The tone across the collection is predominantly positive, with recurring themes of excellent communication, thorough explanations of technical matters, and prompt service—particularly valued during emergency situations in cold weather. Customers frequently highlight the technicians' ability to clearly explain system operations, maintenance recommendations, and available options. The service is repeatedly characterized as courteous and professional, with many customers noting the technicians' transparency and helpfulness. Customers also appreciate the absence of aggressive upselling and the technicians' dedication to resolving problems completely. Overall, the reviews convey a strong sense of customer satisfaction and trust in the technical expertise and customer service provided.

Our Local Reviews by City

Job Locations and Reviews

Completed heat tune up for 3.5 ton R22 heat pump with 20KW electric heat kit,
Installed 11/15/04 21 years old 

20x20x1 filter ok
Indoor and outdoor coils in good condition.
Inspected wiring, controls, electric motors and components. 20KW electric heat amp draw 85A ok. Thermostat cannot be configured to control electric auxiliary heat us. Provided email estimate for WiFi thermostat which will result in savings. 
Told him he can leave the top breaker on the service disconnect at indoor equipment off to downsize the heat kit to 10KW. If he feels uncomfortable he will turn back on. 
Measured temperature rise and static pressure
Inspected drains. There is no trap or overfill protection switch on drain line. Provided estimate for EZ trap. Also provided estimate for wet switch/flood safety 
Verified integrity of compressor and defrost cycle ok.
Checked refrigerant charge/pressures. R22 198/36 ok. 

Heat pump operating ok at this time, but is well beyond Replacement age. Also lacks control of
Completed heat tune up for 3.5 ton R22 heat pump with 20KW electric heat kit,
Installed 11/15/04 21 years old 

20x20x1 filter ok
Indoor and outdoor coils in good condition.
Inspected wiring, controls, electric motors and components. 20KW electric heat amp draw 85A ok. Thermostat cannot be configured to control electric auxiliary heat us. Provided email estimate for WiFi thermostat which will result in savings. 
Told him he can leave the top breaker on the service disconnect at indoor equipment off to downsize the heat kit to 10KW. If he feels uncomfortable he will turn back on. 
Measured temperature rise and static pressure
Inspected drains. There is no trap or overfill protection switch on drain line. Provided estimate for EZ trap. Also provided estimate for wet switch/flood safety 
Verified integrity of compressor and defrost cycle ok.
Checked refrigerant charge/pressures. R22 198/36 ok. 

Heat pump operating ok at this time, but is well beyond Replacement age. Also lacks control of
Barry P.
Barry P. Checked in
Completed heat tune up for 3.5 ton R22 heat pump with 20KW electric heat kit, Installed 11/15/04 21 years old 20x20x1 filter ok Indoor and outdoor coils in good condition. Inspected wiring, controls, electric motors and components. 20KW electric heat amp draw 85A ok. Thermostat cannot be configured to control electric auxiliary heat us. Provided email estimate for WiFi thermostat which will result in savings. Told him he can leave the top breaker on the service disconnect at indoor equipment off to downsize the heat kit to 10KW. If he feels uncomfortable he will turn back on. Measured temperature rise and static pressure Inspected drains. There is no trap or overfill protection switch on drain line. Provided estimate for EZ trap. Also provided estimate for wet switch/flood safety Verified integrity of compressor and defrost cycle ok. Checked refrigerant charge/pressures. R22 198/36 ok. Heat pump operating ok at this time, but is well beyond Replacement age. Also lacks control of
Paoli, PA 19301
Performed precision heat pump tune up on 2021 amana heat pump system. Replaced aprilaire 213 air filter, provided by homeowner. Checked all electrical connections and components. Checked temperature rise. Tested emergency heat. Checked refrigerant pressures and temperature and indoor and outdoor units. Provided estimate to install uv bulb to kill any bacteria on evaporator coil. Heat pump is working properly at time of service.
Performed precision heat pump tune up on 2021 amana heat pump system. Replaced aprilaire 213 air filter, provided by homeowner. Checked all electrical connections and components. Checked temperature rise. Tested emergency heat. Checked refrigerant pressures and temperature and indoor and outdoor units. Provided estimate to install uv bulb to kill any bacteria on evaporator coil. Heat pump is working properly at time of service.
Kurt M.
Kurt M. Checked in
Performed precision heat pump tune up on 2021 amana heat pump system. Replaced aprilaire 213 air filter, provided by homeowner. Checked all electrical connections and components. Checked temperature rise. Tested emergency heat. Checked refrigerant pressures and temperature and indoor and outdoor units. Provided estimate to install uv bulb to kill any bacteria on evaporator coil. Heat pump is working properly at time of service.
Paoli, PA 19301
Review
Trust
Paul - Paoli, PA 19301
Luis 2-10-26 performed gas heat tune on 2011 Ruud gas heater 90%. Check all electrical low and high ok. Replace customer supplied 413 filter. Check ignition components, air delivery motor and wheel, inspect combustion removal system. Performed combustion test ok. Temperature rise ok. I noticed burners and sensor had some rust. I cleaned them as much as possible. Heat exchanger is showing wear. Unit is 15 years old. I provided estimate to replace burners, sensor and igniter, Would recommend getting an estimate for replacement of system. Unit is over life expectancy, all parts are original to system, system is operating properly at the time of service.
Luis 2-10-26 performed gas heat tune on 2011 Ruud gas heater 90%. Check all electrical low and high ok. Replace customer supplied 413 filter. Check ignition components, air delivery motor and wheel, inspect combustion removal system. Performed combustion test ok. Temperature rise ok. I noticed burners and sensor had some rust. I cleaned them as much as possible. Heat exchanger is showing wear. Unit is 15 years old. I provided estimate to replace burners, sensor and igniter, Would recommend getting an estimate for replacement of system. Unit is over life expectancy, all parts are original to system, system is operating properly at the time of service.
Luis T.
Luis T. Checked in
Luis 2-10-26 performed gas heat tune on 2011 Ruud gas heater 90%. Check all electrical low and high ok. Replace customer supplied 413 filter. Check ignition components, air delivery motor and wheel, inspect combustion removal system. Performed combustion test ok. Temperature rise ok. I noticed burners and sensor had some rust. I cleaned them as much as possible. Heat exchanger is showing wear. Unit is 15 years old. I provided estimate to replace burners, sensor and igniter, Would recommend getting an estimate for replacement of system. Unit is over life expectancy, all parts are original to system, system is operating properly at the time of service.
Paoli, PA 19301
Customer called in for no heat, oil boiler. System, has four zones. Three zones are working. Number two, which is kitchen, dining room, living room entertainment area. I tested valve ok.  Both sides of valve are hot, I noticed no water is flowing back to boiler from that zone. all other zones have plenty of water coming back. Could be restriction or frozen pipe. Customer will need to contact plumber for this issue. I also purger is leaking I added cap for now this should also be fix.
Customer called in for no heat, oil boiler. System, has four zones. Three zones are working. Number two, which is kitchen, dining room, living room entertainment area. I tested valve ok.  Both sides of valve are hot, I noticed no water is flowing back to boiler from that zone. all other zones have plenty of water coming back. Could be restriction or frozen pipe. Customer will need to contact plumber for this issue. I also purger is leaking I added cap for now this should also be fix.
Luis T.
Luis T. Checked in
Customer called in for no heat, oil boiler. System, has four zones. Three zones are working. Number two, which is kitchen, dining room, living room entertainment area. I tested valve ok. Both sides of valve are hot, I noticed no water is flowing back to boiler from that zone. all other zones have plenty of water coming back. Could be restriction or frozen pipe. Customer will need to contact plumber for this issue. I also purger is leaking I added cap for now this should also be fix.
Paoli, PA 19301

The pressure trannsducer will be replaced in accordance with Bosch bulletin using a tee and installing the transducer outside of the cabinet.  Rewire the unit and test operation.

Part is listed as under warranty.,  Complete warranty paperwork and return with vendor.

2/6/26
Installed new pressure transducer at outdoor service port using 1/4” SAE swivel tee. Flared the 1/4” inducer tubing. Used a flare tire fitting/gasket here. Tightened all tee firings. Checked for leaks using soap bubbles.
Ran new wire to control. 
Ran system 20 min with probes on.
Compared measured liquid pressure to liquid pressure recognized by the control. 304 measured pressure 308 on control: Good
Also followed Bosch procedures and checked  Volts DC between two points on the connector. Found to be good.

System operating well at this time.

Collected payment.

The pressure trannsducer will be replaced in accordance with Bosch bulletin using a tee and installing the transducer outside of the cabinet.  Rewire the unit and test operation.

Part is listed as under warranty.,  Complete warranty paperwork and return with vendor.

2/6/26
Installed new pressure transducer at outdoor service port using 1/4” SAE swivel tee. Flared the 1/4” inducer tubing. Used a flare tire fitting/gasket here. Tightened all tee firings. Checked for leaks using soap bubbles.
Ran new wire to control. 
Ran system 20 min with probes on.
Compared measured liquid pressure to liquid pressure recognized by the control. 304 measured pressure 308 on control: Good
Also followed Bosch procedures and checked  Volts DC between two points on the connector. Found to be good.

System operating well at this time.

Collected payment.
Barry P.
Barry P. Checked in
The pressure trannsducer will be replaced in accordance with Bosch bulletin using a tee and installing the transducer outside of the cabinet. Rewire the unit and test operation. Part is listed as under warranty., Complete warranty paperwork and return with vendor. 2/6/26 Installed new pressure transducer at outdoor service port using 1/4” SAE swivel tee. Flared the 1/4” inducer tubing. Used a flare tire fitting/gasket here. Tightened all tee firings. Checked for leaks using soap bubbles. Ran new wire to control. Ran system 20 min with probes on. Compared measured liquid pressure to liquid pressure recognized by the control. 304 measured pressure 308 on control: Good Also followed Bosch procedures and checked Volts DC between two points on the connector. Found to be good. System operating well at this time. Collected payment.
Paoli, PA 19301
I arrived to the customers home to look at his Bosch heat pump system. The system is 3 years old, and it’s a second homeowner from this was installed. I found that I had the same lockout code on the outdoor unit H5. I did reset the unit and go through my testing process to see what is going on with the heat pump system. I started up in the attic to be sure. The air filter was OK. Air filter size is 20 x 22 x1. My Gauges I have 55 psi and 265psi. Board -  72psi / 14 psi I ran a test on my transducer and it failed I have 5 dc volts which it needs but my pressure ratio needs to be 0- 4.0 I have 222.6 . Transducer is failed. No charge for today recall . Management will reach out to the customer to see if there is any kind of warranty on the part and the pricing and availability on the transducer.
I arrived to the customers home to look at his Bosch heat pump system. The system is 3 years old, and it’s a second homeowner from this was installed. I found that I had the same lockout code on the outdoor unit H5. I did reset the unit and go through my testing process to see what is going on with the heat pump system. I started up in the attic to be sure. The air filter was OK. Air filter size is 20 x 22 x1. My Gauges I have 55 psi and 265psi. Board -  72psi / 14 psi I ran a test on my transducer and it failed I have 5 dc volts which it needs but my pressure ratio needs to be 0- 4.0 I have 222.6 . Transducer is failed. No charge for today recall . Management will reach out to the customer to see if there is any kind of warranty on the part and the pricing and availability on the transducer.
Daniel R.
Daniel R. Checked in
I arrived to the customers home to look at his Bosch heat pump system. The system is 3 years old, and it’s a second homeowner from this was installed. I found that I had the same lockout code on the outdoor unit H5. I did reset the unit and go through my testing process to see what is going on with the heat pump system. I started up in the attic to be sure. The air filter was OK. Air filter size is 20 x 22 x1. My Gauges I have 55 psi and 265psi. Board - 72psi / 14 psi I ran a test on my transducer and it failed I have 5 dc volts which it needs but my pressure ratio needs to be 0- 4.0 I have 222.6 . Transducer is failed. No charge for today recall . Management will reach out to the customer to see if there is any kind of warranty on the part and the pricing and availability on the transducer.
Paoli, PA 19301
1/28/26 Dan 

I arrived to the customers home that the furnace isn’t running. Found the gas Weil McLain  boiler not heating. I have a call from the thermostat and the circulator is running, found the pilot light was out the thermocouple isn’t holding the flame. I quoted for new thermocouple , and talked to the customer and had told him that it could also be the gas valve not holding the flame. He went ahead and approved the thermocouple repair. I replaced the thermocouple and it held the flame. I tested for combustion and it passed. I Did highly recommend to the customer that the boiler should be replaced in the near future . It’s 28 yrs old . I collected for diagnostic and repair for $483.18 paid by cc. 

I did leave an estimate for a boiler contract for the customers to review.
1/28/26 Dan 

I arrived to the customers home that the furnace isn’t running. Found the gas Weil McLain  boiler not heating. I have a call from the thermostat and the circulator is running, found the pilot light was out the thermocouple isn’t holding the flame. I quoted for new thermocouple , and talked to the customer and had told him that it could also be the gas valve not holding the flame. He went ahead and approved the thermocouple repair. I replaced the thermocouple and it held the flame. I tested for combustion and it passed. I Did highly recommend to the customer that the boiler should be replaced in the near future . It’s 28 yrs old . I collected for diagnostic and repair for $483.18 paid by cc. 

I did leave an estimate for a boiler contract for the customers to review.
Daniel R.
Daniel R. Checked in
1/28/26 Dan I arrived to the customers home that the furnace isn’t running. Found the gas Weil McLain boiler not heating. I have a call from the thermostat and the circulator is running, found the pilot light was out the thermocouple isn’t holding the flame. I quoted for new thermocouple , and talked to the customer and had told him that it could also be the gas valve not holding the flame. He went ahead and approved the thermocouple repair. I replaced the thermocouple and it held the flame. I tested for combustion and it passed. I Did highly recommend to the customer that the boiler should be replaced in the near future . It’s 28 yrs old . I collected for diagnostic and repair for $483.18 paid by cc. I did leave an estimate for a boiler contract for the customers to review.
Paoli, PA 19301
Found outdoor unit locked out on H5 error code.
5 low pressure lockouts in 100 min.
I enabled the extended defrost dipswitches at outdoor unit, this will allow defrost to run 60 seconds longer to help with returning outdoor coil to a state where it can act as heat pump
Checked filter. It is clean. The correct size filter for this air handler is a 20x22x1. He has been using the 20x20x1.
Afterwards tested system.
Had probes on refrigerant ports.
Lowest the suction pressure got was 54 psi. Not low enough for a low pressure incident.
Temperature rise after 15 mi. Was 70-105 or 35° Good
There is no supplemental electric heat kit in air handler so during defrost they will feel cold air from supply ducts/vents. 

There is some snow inside outdoor unit. We poured hot water on sections of piping at outdoor unit that were covered in snow. 

It is better to assess refrigerant charge on the cooling season. 

System operating well at this time. 

There is an oil boiler with (3) zones.
There is a le
Found outdoor unit locked out on H5 error code.
5 low pressure lockouts in 100 min.
I enabled the extended defrost dipswitches at outdoor unit, this will allow defrost to run 60 seconds longer to help with returning outdoor coil to a state where it can act as heat pump
Checked filter. It is clean. The correct size filter for this air handler is a 20x22x1. He has been using the 20x20x1.
Afterwards tested system.
Had probes on refrigerant ports.
Lowest the suction pressure got was 54 psi. Not low enough for a low pressure incident.
Temperature rise after 15 mi. Was 70-105 or 35° Good
There is no supplemental electric heat kit in air handler so during defrost they will feel cold air from supply ducts/vents. 

There is some snow inside outdoor unit. We poured hot water on sections of piping at outdoor unit that were covered in snow. 

It is better to assess refrigerant charge on the cooling season. 

System operating well at this time. 

There is an oil boiler with (3) zones.
There is a le
Barry P.
Barry P. Checked in
Found outdoor unit locked out on H5 error code. 5 low pressure lockouts in 100 min. I enabled the extended defrost dipswitches at outdoor unit, this will allow defrost to run 60 seconds longer to help with returning outdoor coil to a state where it can act as heat pump Checked filter. It is clean. The correct size filter for this air handler is a 20x22x1. He has been using the 20x20x1. Afterwards tested system. Had probes on refrigerant ports. Lowest the suction pressure got was 54 psi. Not low enough for a low pressure incident. Temperature rise after 15 mi. Was 70-105 or 35° Good There is no supplemental electric heat kit in air handler so during defrost they will feel cold air from supply ducts/vents. There is some snow inside outdoor unit. We poured hot water on sections of piping at outdoor unit that were covered in snow. It is better to assess refrigerant charge on the cooling season. System operating well at this time. There is an oil boiler with (3) zones. There is a le
Paoli, PA 19301
Homeowner’s carbon monoxide detector went off late last night.
He was using his wood fired fire place in living room.
I did an ambient carbon monoxide search throughout the house.
Also did ambient Carbon monoxide test in the ductwork of each system while running 0 ppm million,
Combustion analysis/test for each furnace: Pass
The only time where I had a brief blip of 1 ppm but it quickly zeroed out. was when I was within 5’ of wood burning fireplace.
Chances are the CO detector malfunctioned last night.

Also replaced the 20x25x5 filter at basement system. It is a MERV 16 filter so replace every 3 months. 

His detectors are 12+ years old. I offered a low level carbon monoxide alarm. He is going to replace them.
Homeowner’s carbon monoxide detector went off late last night.
He was using his wood fired fire place in living room.
I did an ambient carbon monoxide search throughout the house.
Also did ambient Carbon monoxide test in the ductwork of each system while running 0 ppm million,
Combustion analysis/test for each furnace: Pass
The only time where I had a brief blip of 1 ppm but it quickly zeroed out. was when I was within 5’ of wood burning fireplace.
Chances are the CO detector malfunctioned last night.

Also replaced the 20x25x5 filter at basement system. It is a MERV 16 filter so replace every 3 months. 

His detectors are 12+ years old. I offered a low level carbon monoxide alarm. He is going to replace them.
Barry P.
Barry P. Checked in
Homeowner’s carbon monoxide detector went off late last night. He was using his wood fired fire place in living room. I did an ambient carbon monoxide search throughout the house. Also did ambient Carbon monoxide test in the ductwork of each system while running 0 ppm million, Combustion analysis/test for each furnace: Pass The only time where I had a brief blip of 1 ppm but it quickly zeroed out. was when I was within 5’ of wood burning fireplace. Chances are the CO detector malfunctioned last night. Also replaced the 20x25x5 filter at basement system. It is a MERV 16 filter so replace every 3 months. His detectors are 12+ years old. I offered a low level carbon monoxide alarm. He is going to replace them.
Paoli, PA 19301
Fully assessed humidifier not humidifying as well as it should. Found winter summer damper not open all the way. Showed Kate how to open all the way. Also found humidifier pad full of calcium and debris and needed serviced anyway. Serviced humidifier with #35 pad and flushed out drain. Tested humidifier operation. Humidifier is working properly at time of service.
Fully assessed humidifier not humidifying as well as it should. Found winter summer damper not open all the way. Showed Kate how to open all the way. Also found humidifier pad full of calcium and debris and needed serviced anyway. Serviced humidifier with #35 pad and flushed out drain. Tested humidifier operation. Humidifier is working properly at time of service.
Kurt M.
Kurt M. Checked in
Fully assessed humidifier not humidifying as well as it should. Found winter summer damper not open all the way. Showed Kate how to open all the way. Also found humidifier pad full of calcium and debris and needed serviced anyway. Serviced humidifier with #35 pad and flushed out drain. Tested humidifier operation. Humidifier is working properly at time of service.
Paoli, PA 19301
Review
He was very knowledgeable, friendly, courteous and helpful
Mary - Paoli, PA 19301
Review
On time, polite, friendly, helpful, would carefully explain any questions about my system, neat and clean. I really like this technician.
Richard Weinstein - Paoli, PA 19355
Response from DiBiase Heating and Cooling Company:

Hello Richard! Thank you for sharing your experience! We’re thrilled to hear your technician was on time, friendly, and took the time to answer all your questions. We’ll be sure to pass along your kind words—it means a lot to know their professionalism and care made such a great impression.

Review
We had service tech Kurt arrive for our yearly AC system check up. Kurt was on time, friendly and had a deep knowledge of HVAC systems. He ran a complete battery of tests on our old system, while never getting bothered by the homeowner standing there, asking questions. We are very happy with the level of service and care Kurt provided. Ask for him...you will be impressed! 10/2025, Fall heater service. Kurt returned, this time to check and prepare out heating system for the coming winter. I requested Kurt because I thought he would be just as thorough and knowledgeable with out heating as he had been with out AC....and he was. Everything I said above still applies. After completing the service call, I received an email with docs & photos of all the tests and their results. DiBiase has been reasonable with their pricing, delivered on their service, and honesty....no pressure or up-selling for work thats not needed. Thanks DiBiase!
J8stringer - Paoli, PA 19301
Response from DiBiase Heating and Cooling Company:

Hey there! Thank you for the fantastic review! We're so glad to hear that Kurt provided such thorough, knowledgeable, and friendly service during your AC check-up. We know how important it is to feel confident in your system—especially with an older unit—and we're thrilled Kurt was able to answer your questions and leave such a great impression. We’ll be sure to pass along your kind words to him. Thanks again for choosing DiBiase Heating and Cooling!

Review
We had service tech Kurt arrive for our yearly AC system check up. Kurt was on time, friendly and had a deep knowledge of HVAC systems. He ran a complete battery of tests on our old system, while never getting bothered by the homeowner standing there, asking questions. We are very happy with the level of service and care Kurt provided.
Joseph - Paoli, PA 19301
Review
Great service with a very knowledgeable technician.
Joe - Paoli, PA 19301
Review
Dan was so experienced and explained everything in detail
Dipannita Ghosh - Paoli, PA 19301
Response from DiBiase Heating and Cooling Company:

Hello Dipannita! Thank you for the great feedback! We’re glad to hear Dan took the time to explain everything clearly and provided you with a great experience. At DiBiase, we believe in keeping our customers informed and confident in their decisions. We appreciate you choosing us!

Review
Excellent service
Xiyan - Paoli, PA 19301
Review
zhaohui ao - Paoli, PA 19301
Response from DiBiase Heating and Cooling Company:

Hello Zhaohui! We greatly appreciate you leaving us a 5-star review!

Review
He did a great job
Eileen - Paoli, PA 19301
Review
Barry explained everything clearly and concisely
Jodi - Paoli, PA 19301
Response from DiBiase Heating and Cooling Company:

It was a pleasure serving you and your family. Thank you for sharing your kind words with us. It means the world to us and to our entire team!

Review
DiBiase HVAC have quickly and effectively answered our calls and got the right people for each job. Replacement quote, service, and todays emergency call. Barry,, thank YOU., for ensuring all is safe and burning clean.. Mr Tony, cannot thank you enough for Moms timely quote, and the kind patient reminder/ discussion with all Mom has going on. Angela, thank you for professionally handling our multiple calls.
Brian Wilkerson - Paoli, PA 19301
Response from DiBiase Heating and Cooling Company:

Hi Brian! Thank you for the kind review! We're glad Kurt was able to provide cost-effective solutions for your ductwork and take the time to discuss your future propane hot water needs. We appreciate your trust in DiBiase and look forward to helping you again whenever you need us!

Review
Technician arrived towards the beginning of the window and completed everything promptly. I appreciate that he explained that a part was starting to fail but didnt need to be replaced today and then later sent a formal quote to replace the part at a later time me.
Matt Gauthier - Paoli, PA 19301
Response from DiBiase Heating and Cooling Company:

Hello Matt! Thank you for the great review! We're happy to hear your technician arrived right on time and provided clear, thorough service. We always aim to make every visit as smooth and informative as possible. Thanks for choosing DiBiase Heating and Cooling!

Review
Efficient, helpful and knowledgeable
Jodi - Paoli, PA 19301
Review
As always, a great job well done. Very friendly and professional.
Nancy Hirschle - Paoli, PA 19301
Response from DiBiase Heating and Cooling Company:

Hello Nancy! Thank you for your kind words! We're thrilled to consistently meet your expectations and appreciate your continued trust in us. We look forward to serving you again in the future!

Review
I have trusted DiBiase for more than a decade
Paul - Paoli, PA 19301
Review
Barry was very professional & courteous.
Theresa - Paoli, PA 19301
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next