Expert HVAC Service and More in Pottstown, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Pottstown, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in Pottstown, PA

Rated 4.9 out of 5 stars based on 28 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting a high level of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and efficiency demonstrated by the service team. A dominant theme throughout is the technicians' exceptional communication skills, with reviewers frequently praising how thoroughly issues were explained in clear, understandable terms. The company's customer-focused approach emerges as a standout quality, with multiple mentions of staff going above and beyond expectations, taking extra time to answer questions, and showing genuine care for customer needs. Reviewers repeatedly highlight the knowledgeable and friendly demeanor of the technicians, noting their respectfulness toward property and their ability to provide detailed assessments. The thoroughness of inspections and maintenance visits receives particular acclaim, with customers expressing confidence in the quality of work performed. Many reviews emphasize positive ongoing relationships, indicating strong customer loyalty and satisfaction with repeat service experiences. The sentiment of trust is evident, with customers appreciating honest recommendations and feeling empowered to make informed decisions. Overall, the tone is enthusiastically positive, conveying a sense of relief and satisfaction that the company delivers exceptional, reliable service that exceeds modern expectations for integrity and customer care.

Pottstown, PA at a glance

DiBiase Heating and Cooling Company has completed 10 jobs in Pottstown, PA between August 2026 and October 2026.

The 15 customer reviews shown here average 5.0 out of 5.

The most recent job was on October 21, 2026.

DiBiase Heating and Cooling Company has completed 54 jobs in Pottstown, PA in the last 12 months. The first job there was in December 2023.

Our Local Reviews by City

Job Locations and Reviews

On 10/21, I conducted a comprehensive heat pump check-up on a 3-year-old Bosch system. I meticulously examined all electrical connections and voltages, ensuring they were within safe parameters. The air filter was replaced with a size 213, provided by the customer. I inspected the indoor coil and blower motor, measuring amperage draws. Indoor temperature splits were recorded at the supply and return. The outdoor heat pump was tested for BTU output and unit pressures. All outdoor components were inspected, and everything was found to be functioning optimally.
On 10/21, I conducted a comprehensive heat pump check-up on a 3-year-old Bosch system. I meticulously examined all electrical connections and voltages, ensuring they were within safe parameters. The air filter was replaced with a size 213, provided by the customer. I inspected the indoor coil and blower motor, measuring amperage draws. Indoor temperature splits were recorded at the supply and return. The outdoor heat pump was tested for BTU output and unit pressures. All outdoor components were inspected, and everything was found to be functioning optimally.
Daniel R.
Daniel R. Checked in
On 10/21, I conducted a comprehensive heat pump check-up on a 3-year-old Bosch system. I meticulously examined all electrical connections and voltages, ensuring they were within safe parameters. The air filter was replaced with a size 213, provided by the customer. I inspected the indoor coil and blower motor, measuring amperage draws. Indoor temperature splits were recorded at the supply and return. The outdoor heat pump was tested for BTU output and unit pressures. All outdoor components were inspected, and everything was found to be functioning optimally.
Pottstown, PA 19465
On 10/20/26, I inspected a thermostat that was calling for heat but found no response from the system. After bypassing the boiler at the t&t terminals, it successfully activated. However, bypassing at the thermostat base yielded no results. I traced the wiring and examined all wire nut connections, discovering a broken connection on the white wire. After reconnecting and testing, the boiler resumed proper operation. No charge was applied due to the nature of the installation.
On 10/20/26, I inspected a thermostat that was calling for heat but found no response from the system. After bypassing the boiler at the t&t terminals, it successfully activated. However, bypassing at the thermostat base yielded no results. I traced the wiring and examined all wire nut connections, discovering a broken connection on the white wire. After reconnecting and testing, the boiler resumed proper operation. No charge was applied due to the nature of the installation.
Kurt M.
Kurt M. Checked in
On 10/20/26, I inspected a thermostat that was calling for heat but found no response from the system. After bypassing the boiler at the t&t terminals, it successfully activated. However, bypassing at the thermostat base yielded no results. I traced the wiring and examined all wire nut connections, discovering a broken connection on the white wire. After reconnecting and testing, the boiler resumed proper operation. No charge was applied due to the nature of the installation.
Pottstown, PA 19465
On October 14, I assessed a no-cooling issue with a 2021 Amana communicating hybrid system. Using the Cool Cloud, I connected to the indoor unit and identified a major low line voltage error, causing the system to lock out. This error arises when the incoming line voltage is insufficient for the communicating system to operate. I explained to the customer that no action could be taken until the voltage normalized. After power restoration, I reset the indoor and outdoor unit breakers, tested the system, and checked voltages and 410A refrigerant pressures. During the visit, a power outage occurred, and the backup generator activated, prompting me to inform the customer about potential breaker resets.
On October 14, I assessed a no-cooling issue with a 2021 Amana communicating hybrid system. Using the Cool Cloud, I connected to the indoor unit and identified a major low line voltage error, causing the system to lock out. This error arises when the incoming line voltage is insufficient for the communicating system to operate. I explained to the customer that no action could be taken until the voltage normalized. After power restoration, I reset the indoor and outdoor unit breakers, tested the system, and checked voltages and 410A refrigerant pressures. During the visit, a power outage occurred, and the backup generator activated, prompting me to inform the customer about potential breaker resets.
Kurt M.
Kurt M. Checked in
On October 14, I assessed a no-cooling issue with a 2021 Amana communicating hybrid system. Using the Cool Cloud, I connected to the indoor unit and identified a major low line voltage error, causing the system to lock out. This error arises when the incoming line voltage is insufficient for the communicating system to operate. I explained to the customer that no action could be taken until the voltage normalized. After power restoration, I reset the indoor and outdoor unit breakers, tested the system, and checked voltages and 410A refrigerant pressures. During the visit, a power outage occurred, and the backup generator activated, prompting me to inform the customer about potential breaker resets.
Pottstown, PA 19465
On 10/10/26, I assessed a heating issue with a 2025 Trane Link hybrid system. Upon arrival, the thermostat appeared satisfied, but an error code indicated the A2L sensor was not connected to the mitigation board. After verifying the connection, I discovered the blower was running continuously on the gas furnace. Although there is no bypass option for the A2L sensor in the Trane Link setup, switching to emergency heat allowed the system to function normally. I also switched to the propane furnace. The issue began after a recent power blip, and a maintenance visit two days prior. I ordered a new mitigation sensor, which will be returned and installed. The customer currently has heat, and no charge was applied under the 2-year warranty.
On 10/10/26, I assessed a heating issue with a 2025 Trane Link hybrid system. Upon arrival, the thermostat appeared satisfied, but an error code indicated the A2L sensor was not connected to the mitigation board. After verifying the connection, I discovered the blower was running continuously on the gas furnace. Although there is no bypass option for the A2L sensor in the Trane Link setup, switching to emergency heat allowed the system to function normally. I also switched to the propane furnace. The issue began after a recent power blip, and a maintenance visit two days prior. I ordered a new mitigation sensor, which will be returned and installed. The customer currently has heat, and no charge was applied under the 2-year warranty.
Kurt M.
Kurt M. Checked in
On 10/10/26, I assessed a heating issue with a 2025 Trane Link hybrid system. Upon arrival, the thermostat appeared satisfied, but an error code indicated the A2L sensor was not connected to the mitigation board. After verifying the connection, I discovered the blower was running continuously on the gas furnace. Although there is no bypass option for the A2L sensor in the Trane Link setup, switching to emergency heat allowed the system to function normally. I also switched to the propane furnace. The issue began after a recent power blip, and a maintenance visit two days prior. I ordered a new mitigation sensor, which will be returned and installed. The customer currently has heat, and no charge was applied under the 2-year warranty.
Pottstown, PA 19465
On October 6, I conducted a quality assurance inspection on a single head Hisense mini split heat pump system. The customer reported that in cooling mode, with the room temperature at 68 degrees and the set temperature at 77 degrees, the fan continued to run. I contacted Hisense technician support, who confirmed this as the correct operating procedure. The fan operates at medium speed to air sample the room and dry out the indoor coil. This feature is not present in heating mode due to the coil not being wet. I also checked the settings in the power monitoring box and ensured all electrical connections were secure. The mini split heat pump is functioning correctly.
On October 6, I conducted a quality assurance inspection on a single head Hisense mini split heat pump system. The customer reported that in cooling mode, with the room temperature at 68 degrees and the set temperature at 77 degrees, the fan continued to run. I contacted Hisense technician support, who confirmed this as the correct operating procedure. The fan operates at medium speed to air sample the room and dry out the indoor coil. This feature is not present in heating mode due to the coil not being wet. I also checked the settings in the power monitoring box and ensured all electrical connections were secure. The mini split heat pump is functioning correctly.
Kurt M.
Kurt M. Checked in
On October 6, I conducted a quality assurance inspection on a single head Hisense mini split heat pump system. The customer reported that in cooling mode, with the room temperature at 68 degrees and the set temperature at 77 degrees, the fan continued to run. I contacted Hisense technician support, who confirmed this as the correct operating procedure. The fan operates at medium speed to air sample the room and dry out the indoor coil. This feature is not present in heating mode due to the coil not being wet. I also checked the settings in the power monitoring box and ensured all electrical connections were secure. The mini split heat pump is functioning correctly.
Pottstown, PA 19464
On September 29, I installed new vinyl piping from the heater condensation pump to the sump pump. This involved carefully measuring and cutting the existing vinyl to ensure a precise fit. I then added a coupling to seal the old existing vinyl discharge sewer, ensuring there were no leaks. The condensation pump was successfully connected to the sump pump, which the customer confirmed was operational. I tested the condensation pump to verify it was functioning correctly, ensuring efficient drainage. The entire process was completed with attention to detail, ensuring all connections were secure and leak-free.
On September 29, I installed new vinyl piping from the heater condensation pump to the sump pump. This involved carefully measuring and cutting the existing vinyl to ensure a precise fit. I then added a coupling to seal the old existing vinyl discharge sewer, ensuring there were no leaks. The condensation pump was successfully connected to the sump pump, which the customer confirmed was operational. I tested the condensation pump to verify it was functioning correctly, ensuring efficient drainage. The entire process was completed with attention to detail, ensuring all connections were secure and leak-free.
Luis T.
Luis T. Checked in
On September 29, I installed new vinyl piping from the heater condensation pump to the sump pump. This involved carefully measuring and cutting the existing vinyl to ensure a precise fit. I then added a coupling to seal the old existing vinyl discharge sewer, ensuring there were no leaks. The condensation pump was successfully connected to the sump pump, which the customer confirmed was operational. I tested the condensation pump to verify it was functioning correctly, ensuring efficient drainage. The entire process was completed with attention to detail, ensuring all connections were secure and leak-free.
Pottstown, PA 19465
Luis 9-23-26
Performed propane gas heat inspection on a newer Bosch heater/heat pump 3 years old. 413 filter ok.
Check all electrical connections and components check air delivery system clean combustion components, igniter and sensor inspect burners and offices check low and high stage. Perform combustion test check supply and return air temperature difference ok. Test water safety recycle system OK Bosch system is working properly at a time of service. 

Heat pump inspection on 1.5 trane HP from 1999. 8 kw electric heat ok test and check all electrical connections and components indoor and outdoor. Customer know unit is old and we have previously informed about issues, capacitors reading below standards, major biological growth inside unit. Outdoor unit compressor is having difficulties compressing refrigerant. Valves working harder to over come friction. 
Outdoor capacitor is below tolerance. Reversing valve actuator heavily corroded very hard to test or remove wires. 
Customer know
Luis 9-23-26
Performed propane gas heat inspection on a newer Bosch heater/heat pump 3 years old. 413 filter ok.
Check all electrical connections and components check air delivery system clean combustion components, igniter and sensor inspect burners and offices check low and high stage. Perform combustion test check supply and return air temperature difference ok. Test water safety recycle system OK Bosch system is working properly at a time of service. 

Heat pump inspection on 1.5 trane HP from 1999. 8 kw electric heat ok test and check all electrical connections and components indoor and outdoor. Customer know unit is old and we have previously informed about issues, capacitors reading below standards, major biological growth inside unit. Outdoor unit compressor is having difficulties compressing refrigerant. Valves working harder to over come friction. 
Outdoor capacitor is below tolerance. Reversing valve actuator heavily corroded very hard to test or remove wires. 
Customer know
Luis T.
Luis T. Checked in
Luis 9-23-26 Performed propane gas heat inspection on a newer Bosch heater/heat pump 3 years old. 413 filter ok. Check all electrical connections and components check air delivery system clean combustion components, igniter and sensor inspect burners and offices check low and high stage. Perform combustion test check supply and return air temperature difference ok. Test water safety recycle system OK Bosch system is working properly at a time of service. Heat pump inspection on 1.5 trane HP from 1999. 8 kw electric heat ok test and check all electrical connections and components indoor and outdoor. Customer know unit is old and we have previously informed about issues, capacitors reading below standards, major biological growth inside unit. Outdoor unit compressor is having difficulties compressing refrigerant. Valves working harder to over come friction. Outdoor capacitor is below tolerance. Reversing valve actuator heavily corroded very hard to test or remove wires. Customer know
Pottstown, PA 19464
Review
Technician Barry was quick, courteous, took care to keep the house clean as he went in and out, and provided real information on the problem with the AC system rather than a sales pitch.
Mike Campbell - Pottstown, PA 19465
2.5 Ton Lennox AC piston metering with gas furnace dates to October 2019.

*Used Lennox warranty verification to determine warranty expired 2025

System running in a vacuum.
Empty of refrigerant.
Leak can be heard at indoor coil. *Because system was running in a vacuum for a short period air can be heard sucking into the leak point of coil. 
Indoor coil needs to be replaced. 
Very important to consider that because compressor has been running in a vacuum for unknown amount of time, compressor failure is likely soon.

Explained everything to homeowner. Sent email estimate to replace indoor coil and install new low pressure switch. Also scheduled sales call for AC replacement for today 2PM. 
Also emailed estimate for compressor replacement for homeowners information. 
Left power off to disconnect to prevent compressor from running. Running AC when in a vacuum can cause damage 

• No obligation quote to replace system
• A Comfort Specialist will provide several options to suit your comfor
2.5 Ton Lennox AC piston metering with gas furnace dates to October 2019.

*Used Lennox warranty verification to determine warranty expired 2025

System running in a vacuum.
Empty of refrigerant.
Leak can be heard at indoor coil. *Because system was running in a vacuum for a short period air can be heard sucking into the leak point of coil. 
Indoor coil needs to be replaced. 
Very important to consider that because compressor has been running in a vacuum for unknown amount of time, compressor failure is likely soon.

Explained everything to homeowner. Sent email estimate to replace indoor coil and install new low pressure switch. Also scheduled sales call for AC replacement for today 2PM. 
Also emailed estimate for compressor replacement for homeowners information. 
Left power off to disconnect to prevent compressor from running. Running AC when in a vacuum can cause damage 

• No obligation quote to replace system
• A Comfort Specialist will provide several options to suit your comfor
Barry P.
Barry P. Checked in
2.5 Ton Lennox AC piston metering with gas furnace dates to October 2019. *Used Lennox warranty verification to determine warranty expired 2025 System running in a vacuum. Empty of refrigerant. Leak can be heard at indoor coil. *Because system was running in a vacuum for a short period air can be heard sucking into the leak point of coil. Indoor coil needs to be replaced. Very important to consider that because compressor has been running in a vacuum for unknown amount of time, compressor failure is likely soon. Explained everything to homeowner. Sent email estimate to replace indoor coil and install new low pressure switch. Also scheduled sales call for AC replacement for today 2PM. Also emailed estimate for compressor replacement for homeowners information. Left power off to disconnect to prevent compressor from running. Running AC when in a vacuum can cause damage • No obligation quote to replace system • A Comfort Specialist will provide several options to suit your comfor
Pottstown, PA 19465
Luis 8-6-26
Customer called in for radiators getting warm. I check system operation. I noticed there was a call for heat at Boiler, removed stat from wall and still getting call. I check wiring short or old wiring from original installation of house. I replaced 20 feet of wire and installed thermostat back to base ok. System stayed idle and no more call for heat. I talked to customer about todays repair, customer to contact office if they still have issues. No charge warranty.
Luis 8-6-26
Customer called in for radiators getting warm. I check system operation. I noticed there was a call for heat at Boiler, removed stat from wall and still getting call. I check wiring short or old wiring from original installation of house. I replaced 20 feet of wire and installed thermostat back to base ok. System stayed idle and no more call for heat. I talked to customer about todays repair, customer to contact office if they still have issues. No charge warranty.
Luis T.
Luis T. Checked in
Luis 8-6-26 Customer called in for radiators getting warm. I check system operation. I noticed there was a call for heat at Boiler, removed stat from wall and still getting call. I check wiring short or old wiring from original installation of house. I replaced 20 feet of wire and installed thermostat back to base ok. System stayed idle and no more call for heat. I talked to customer about todays repair, customer to contact office if they still have issues. No charge warranty.
Pottstown, PA 19465
Nathan P.
Nathan P. Checked in
Luis and Nate 8-3-26 Return visit to check water leak from one of the indoor mini split heads. Bedroom unit. Remove unit from bracket add extra insulation to line set. We also corrected drain line so it drain properly. Test operation ok. Customer also told us to check office unit it seems like was dripping at some point, we also added extra insulation and correct drain pitch. Test drain and system operation ok 19 degree split on all three indoor heads. 56/74 no charge warranty.
Pottstown, PA 19464
Review
Great service, people, and company. I highly recommend
Carolyn - Pottstown, PA 19465
Review
On time, professional. Kevin and Isaac had a lot of units due for their annual check. They did an excellent job and didn’t make a mess doing it.
Sharon - Pottstown, PA 19465
Review
Great job..very thorough
Beverly - Pottstown, PA 19464
Review
Great job, professional and very knowledgeable
Susette - Pottstown, PA 19465
Review
Kurt was friendly and knowledgeable.
Michael - Pottstown, PA 19465
Review
Excellent service
Eric - Pottstown, PA 19465
Review
Kurt is an exceptional and knowledgeable technician, and a good guy.
Carolyn - Pottstown, PA 19465
Review
Excellent service
Olumuyiwa - Pottstown, PA 19464
Review
Kurt is great—knowledgeable and kind.
Carolyn - Pottstown, PA 19465
Review
Very professional and furnished useful information for later service/purchase
Susette - Pottstown, PA 19465
Review
Kurt was a pleasure, he found the issue rather quickly and got the condenser working which was the problem. Checked the system pressure and gave it a clean bill of health! Very happy with the service of Kurt and Di Biase Heating and Cooling!
Ray & Kelly Trusdell - Pottstown, PA 19464
Response from DiBiase Heating and Cooling Company:

Hello Ray and Kelly! Thank you for the great review! We're so glad to hear Kurt was able to quickly diagnose and fix the issue with your condenser. It's always our goal to provide fast, reliable service, and we're happy everything checked out in great shape. We’ll be sure to pass along your kind words to Kurt. Thanks again for choosing DiBiase Heating and Cooling!

Review
Conner and Liz did a great job insulating our new house. They were very customer service friendly.
Chris Savo - Pottstown, PA 19465
Response from DiBiase Heating and Cooling Company:

Hi Chris! Thank you for your feedback! We're thrilled to hear that Conner and Liz provided top-notch insulation work and outstanding customer service. Making sure our customers are comfortable in their homes is always our priority. We appreciate your support!

Review
I manage a community DiBiase manages under Associa - Mid Atlantic. He was thorough, friendly and informative. He did not try and sell products we did not need and called prior and post arrival for a report. Thank you Daniel Ruggirello!
Amanda Keegan - Pottstown, PA 19464
Response from DiBiase Heating and Cooling Company:

Hi Amanda! Thank you for your kind words and for taking the time to share your experience! We’re thrilled to hear that Daniel provided thorough, friendly, and informative service while respecting your needs. We appreciate your trust in DiBiase Heating and Cooling and look forward to assisting you in the future!

Review
Today was our very first time dealing with DiBiase Heating and Cooling company. And we were very satisfied with the overall experience. Dan who was our service technician was very professional and courteous. He was able to answer our questions and explain everything that was happening as he serviced our furnace. He was thorough, good communication, and very down-to-earth. Would definitely recommend this company and will use in the future. Thanks Dan.
Derrick T - Pottstown, PA 19464
Response from DiBiase Heating and Cooling Company:

Hi Derrick! Thank you for sharing your first experience with us! We're thrilled to hear that Dan provided professional, courteous, and thorough service while keeping you well-informed. Your recommendation means a lot, and we’re grateful for the opportunity to assist with your furnace. We look forward to helping you again in the future!

Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next