610-873-1244 Book Online Text Us

Landenberg, PA

Expert HVAC Service and More in Landenberg, PA

DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Landenberg, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.

Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!

Recent Jobs and Reviews in Landenberg, PA

Rated 4.9 out of 5 stars based on 8 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently express gratitude for professional, knowledgeable, and courteous technicians who demonstrate expertise in diagnosing and resolving HVAC issues efficiently. A recurring theme is the technicians' ability to clearly explain problems and solutions, making customers feel informed and comfortable throughout the service process. Many reviewers emphasize the thoroughness and attention to detail displayed during installations, repairs, and routine maintenance, with several noting how technicians go above and beyond expectations. The prompt response times, particularly for emergency calls, receive frequent praise, as does the professionalism and respectful demeanor of service personnel. Customers repeatedly express confidence in the quality of work performed and indicate strong willingness to recommend the company to others. The positive tone extends to appreciation for warranty reminders and cost-saving suggestions that demonstrate customer-focused service. Overall, the reviews convey a sense of relief, satisfaction, and trust in the company's ability to deliver reliable, high-quality HVAC services with exceptional customer care.

Our Local Reviews by City

Job Locations and Reviews

Issue is uninsulated ducts are sweating on top of new drop ceiling tiles. 
Happens on hot days. 

2nd Floor Duct dimensions are 8x24” 
He has tried bubble wrapping it himself. It only sags.
Ideally the  cuz drop ceiling needs to be removed or taken apart enough to be able wrap what sections we can.

Relative humidity was 62% measured by my psychrometer. 
I encouraged him to use his plug in dehumidifier but set to 50% or 55%. Which will help. 

Also replaced dirty 16x20x1 filter. I offered to do AC tune up, He has another company doing the AC tune up soon. 

I took as many photos as I could. I recommend site visit from management to give quote for wrapping ducts and installing dehumidifier.
Issue is uninsulated ducts are sweating on top of new drop ceiling tiles. 
Happens on hot days. 

2nd Floor Duct dimensions are 8x24” 
He has tried bubble wrapping it himself. It only sags.
Ideally the  cuz drop ceiling needs to be removed or taken apart enough to be able wrap what sections we can.

Relative humidity was 62% measured by my psychrometer. 
I encouraged him to use his plug in dehumidifier but set to 50% or 55%. Which will help. 

Also replaced dirty 16x20x1 filter. I offered to do AC tune up, He has another company doing the AC tune up soon. 

I took as many photos as I could. I recommend site visit from management to give quote for wrapping ducts and installing dehumidifier.
Barry P.
Barry P. Checked in
Issue is uninsulated ducts are sweating on top of new drop ceiling tiles. Happens on hot days. 2nd Floor Duct dimensions are 8x24” He has tried bubble wrapping it himself. It only sags. Ideally the cuz drop ceiling needs to be removed or taken apart enough to be able wrap what sections we can. Relative humidity was 62% measured by my psychrometer. I encouraged him to use his plug in dehumidifier but set to 50% or 55%. Which will help. Also replaced dirty 16x20x1 filter. I offered to do AC tune up, He has another company doing the AC tune up soon. I took as many photos as I could. I recommend site visit from management to give quote for wrapping ducts and installing dehumidifier.
Landenberg, PA 19350
Equipment is 3.5 Ton heat pump with 10KW electric heat kit.

Homeowner explained that he had a company replace blower motor this past December.
System is not zoned. 2nd floor remains hot in cooling season unless thermostat (on first floor) is set to target temperature 70°.
Ductwork that is in attic for (2) second floor bedrooms is not sealed or insulated. 
*The underside of roof sheathing is insulated but there is no insulation in the bays under plywood. Homeowner may invest in insulating attic to modern standards, Took photos of attic and ducts that are in attic. 

Thermostat does not have input for outdoor temperature. Heat 
Unp drop was set to Comfort. I set to 3° which will control use of 10KW auxiliary heater a little better. Provo estimate to install Honeywell S1200 smart thermostat to be able to lock out electric heat when outdoor temperature is above a setpoint (40°)

Completed tune up. 

Replaced 20x20x1 filter
Indoor and outdoor coils in good condition 
Inspected wiring, cont
Equipment is 3.5 Ton heat pump with 10KW electric heat kit.

Homeowner explained that he had a company replace blower motor this past December.
System is not zoned. 2nd floor remains hot in cooling season unless thermostat (on first floor) is set to target temperature 70°.
Ductwork that is in attic for (2) second floor bedrooms is not sealed or insulated. 
*The underside of roof sheathing is insulated but there is no insulation in the bays under plywood. Homeowner may invest in insulating attic to modern standards, Took photos of attic and ducts that are in attic. 

Thermostat does not have input for outdoor temperature. Heat 
Unp drop was set to Comfort. I set to 3° which will control use of 10KW auxiliary heater a little better. Provo estimate to install Honeywell S1200 smart thermostat to be able to lock out electric heat when outdoor temperature is above a setpoint (40°)

Completed tune up. 

Replaced 20x20x1 filter
Indoor and outdoor coils in good condition 
Inspected wiring, cont
Barry P.
Barry P. Checked in
Equipment is 3.5 Ton heat pump with 10KW electric heat kit. Homeowner explained that he had a company replace blower motor this past December. System is not zoned. 2nd floor remains hot in cooling season unless thermostat (on first floor) is set to target temperature 70°. Ductwork that is in attic for (2) second floor bedrooms is not sealed or insulated. *The underside of roof sheathing is insulated but there is no insulation in the bays under plywood. Homeowner may invest in insulating attic to modern standards, Took photos of attic and ducts that are in attic. Thermostat does not have input for outdoor temperature. Heat Unp drop was set to Comfort. I set to 3° which will control use of 10KW auxiliary heater a little better. Provo estimate to install Honeywell S1200 smart thermostat to be able to lock out electric heat when outdoor temperature is above a setpoint (40°) Completed tune up. Replaced 20x20x1 filter Indoor and outdoor coils in good condition Inspected wiring, cont
Landenberg, PA 19350
AC tune up for 5 Ton AC
Equipment is hybrid propane furnace/heat pump installed last month 5/23/26. 

20x25x4 filter ok recommend replacing every 3-4 months.
Completed AC tune up for 3 Ton Amana AC system
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimates for surge protectors.  Currently has Nest thermostat.
 Provided estimate for Honeywell S1200 thermostat with EIM which will allow for more precise control of furnace staging and furnace lockouts in heating and allow for sensors and accessory wiring, *Cooling fan motor speed set to 450 CFM/ton. Black wire at defrost board is for bringing on auxiliary heat during defrost. Wired it in today,* they had already wired the white conductor between the outdoor unit and indoor control to the W1 terminal. Wired black conductor (X2) from defrost to white W1. 
Measured temperature split and static pressure 
Inspected drains; cleared trap tested pump; wet switch, ez trap and conden
AC tune up for 5 Ton AC
Equipment is hybrid propane furnace/heat pump installed last month 5/23/26. 

20x25x4 filter ok recommend replacing every 3-4 months.
Completed AC tune up for 3 Ton Amana AC system
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimates for surge protectors.  Currently has Nest thermostat.
 Provided estimate for Honeywell S1200 thermostat with EIM which will allow for more precise control of furnace staging and furnace lockouts in heating and allow for sensors and accessory wiring, *Cooling fan motor speed set to 450 CFM/ton. Black wire at defrost board is for bringing on auxiliary heat during defrost. Wired it in today,* they had already wired the white conductor between the outdoor unit and indoor control to the W1 terminal. Wired black conductor (X2) from defrost to white W1. 
Measured temperature split and static pressure 
Inspected drains; cleared trap tested pump; wet switch, ez trap and conden
Barry P.
Barry P. Checked in
AC tune up for 5 Ton AC Equipment is hybrid propane furnace/heat pump installed last month 5/23/26. 20x25x4 filter ok recommend replacing every 3-4 months. Completed AC tune up for 3 Ton Amana AC system Indoor and outdoor coils in good condition Inspected wiring, controls, electric motors and components; left estimates for surge protectors. Currently has Nest thermostat. Provided estimate for Honeywell S1200 thermostat with EIM which will allow for more precise control of furnace staging and furnace lockouts in heating and allow for sensors and accessory wiring, *Cooling fan motor speed set to 450 CFM/ton. Black wire at defrost board is for bringing on auxiliary heat during defrost. Wired it in today,* they had already wired the white conductor between the outdoor unit and indoor control to the W1 terminal. Wired black conductor (X2) from defrost to white W1. Measured temperature split and static pressure Inspected drains; cleared trap tested pump; wet switch, ez trap and conden
Landenberg, PA 19350
Completed (3) Plan member AC tune ups.

3 Ton Minisplit with (2) Ceiling cassettes and (1) wall mount in garage. 6 years old
2 Ton Carrier Heat pump that serves the game room/basement only. Installed 2023 3 years old.
5 Ton Trane heat pump/propane hybrid system installed May 2016 10 years old.

Filters are fiberglass “micro power guard media” (16x25x1) and (16x20x1) and washable for Minisplits. Homeowner will purchase these as needed 

For each system:

-Inspected indoor and outdoor coils Indoor and outdoor coils in good condition. 
-Inspected wiring, controls, electric motors and components; left estimates for surge protectors Carrier outdoor unit and indoor unit, the Minisplit AND the Trane indoor equipment have surge protectors. Outdoor unit main system does not. Left empty estimate 
Measured temperature split and static pressure 
Inspected drains; cleared traps, tested pump; both the traditional split systems would benefit by replacing the pvc traps with traps with cleanout and ove
Completed (3) Plan member AC tune ups.

3 Ton Minisplit with (2) Ceiling cassettes and (1) wall mount in garage. 6 years old
2 Ton Carrier Heat pump that serves the game room/basement only. Installed 2023 3 years old.
5 Ton Trane heat pump/propane hybrid system installed May 2016 10 years old.

Filters are fiberglass “micro power guard media” (16x25x1) and (16x20x1) and washable for Minisplits. Homeowner will purchase these as needed 

For each system:

-Inspected indoor and outdoor coils Indoor and outdoor coils in good condition. 
-Inspected wiring, controls, electric motors and components; left estimates for surge protectors Carrier outdoor unit and indoor unit, the Minisplit AND the Trane indoor equipment have surge protectors. Outdoor unit main system does not. Left empty estimate 
Measured temperature split and static pressure 
Inspected drains; cleared traps, tested pump; both the traditional split systems would benefit by replacing the pvc traps with traps with cleanout and ove
Barry P.
Barry P. Checked in
Completed (3) Plan member AC tune ups. 3 Ton Minisplit with (2) Ceiling cassettes and (1) wall mount in garage. 6 years old 2 Ton Carrier Heat pump that serves the game room/basement only. Installed 2023 3 years old. 5 Ton Trane heat pump/propane hybrid system installed May 2016 10 years old. Filters are fiberglass “micro power guard media” (16x25x1) and (16x20x1) and washable for Minisplits. Homeowner will purchase these as needed For each system: -Inspected indoor and outdoor coils Indoor and outdoor coils in good condition. -Inspected wiring, controls, electric motors and components; left estimates for surge protectors Carrier outdoor unit and indoor unit, the Minisplit AND the Trane indoor equipment have surge protectors. Outdoor unit main system does not. Left empty estimate Measured temperature split and static pressure Inspected drains; cleared traps, tested pump; both the traditional split systems would benefit by replacing the pvc traps with traps with cleanout and ove
Landenberg, PA 19350
Review
Always capable, personable and competent.
Marjorie - Landenberg, PA 19350
Completed (2) AC tune ups. 
1st Floor 3.5 Tons AC dates to 2010 16 years old, furnace is 2019 7 years old 
2nd Floor 3 Ton AC also dates to 2010 16 years old; furnace is 2019 7 years old 

Replaced 16x25x1 filter for 2nd Floor
Replaced 20x25x1 for 1st floor 

For each system: 
Indoor and outdoor coils in good condition; cleaned outdoor coils with available hose  Bib. 2nd floor system has some buildup on backside. But otherwise they were clean. *Units are still level from work done in 2024
Inspected wiring, controls, electric motors and components; left estimates for surge protectors. Home odors have a whole home surge protector at panel. Surge protectors for separate circuits are still recommended
Up to (4) can be installed. 
Measured temperature split and static pressure 
Inspected drains; cleared EZ trap, tested pump; added treatment tabs to drain pan. 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. 

Closed bypass dampers and wa
Completed (2) AC tune ups. 
1st Floor 3.5 Tons AC dates to 2010 16 years old, furnace is 2019 7 years old 
2nd Floor 3 Ton AC also dates to 2010 16 years old; furnace is 2019 7 years old 

Replaced 16x25x1 filter for 2nd Floor
Replaced 20x25x1 for 1st floor 

For each system: 
Indoor and outdoor coils in good condition; cleaned outdoor coils with available hose  Bib. 2nd floor system has some buildup on backside. But otherwise they were clean. *Units are still level from work done in 2024
Inspected wiring, controls, electric motors and components; left estimates for surge protectors. Home odors have a whole home surge protector at panel. Surge protectors for separate circuits are still recommended
Up to (4) can be installed. 
Measured temperature split and static pressure 
Inspected drains; cleared EZ trap, tested pump; added treatment tabs to drain pan. 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. 

Closed bypass dampers and wa
Barry P.
Barry P. Checked in
Completed (2) AC tune ups. 1st Floor 3.5 Tons AC dates to 2010 16 years old, furnace is 2019 7 years old 2nd Floor 3 Ton AC also dates to 2010 16 years old; furnace is 2019 7 years old Replaced 16x25x1 filter for 2nd Floor Replaced 20x25x1 for 1st floor For each system: Indoor and outdoor coils in good condition; cleaned outdoor coils with available hose Bib. 2nd floor system has some buildup on backside. But otherwise they were clean. *Units are still level from work done in 2024 Inspected wiring, controls, electric motors and components; left estimates for surge protectors. Home odors have a whole home surge protector at panel. Surge protectors for separate circuits are still recommended Up to (4) can be installed. Measured temperature split and static pressure Inspected drains; cleared EZ trap, tested pump; added treatment tabs to drain pan. Checked integrity of compressor motor (mega ohm test) Assessed refrigerant charge checked pressures. Closed bypass dampers and wa
Landenberg, PA 19350
Completed AC tune up for 4 Ton Goodman AC system

Furnace is 9 years old. AC is approximately 3 years old

Replaced 16x20x1 filter with one provided by homeowner 
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimates for surge protectors. The Y conductor between the thermostat and the indoor equipment control is shorted and the green conductor is therefore used for the cooling contact. There is no way of controlling the fan. The only way to address this is to install a thermostat with an EIM. A wire pull is not feasible. Wire is anchored and basement ceilimgs are drywall. 
 *The cost of repairs for components that may be damaged by surges can far exceed the cost of surge protectors
Measured temperature split and static pressure 
Inspected drains; cleared EZ trap, 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. Good

AC system operating well at this time.
Completed AC tune up for 4 Ton Goodman AC system

Furnace is 9 years old. AC is approximately 3 years old

Replaced 16x20x1 filter with one provided by homeowner 
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimates for surge protectors. The Y conductor between the thermostat and the indoor equipment control is shorted and the green conductor is therefore used for the cooling contact. There is no way of controlling the fan. The only way to address this is to install a thermostat with an EIM. A wire pull is not feasible. Wire is anchored and basement ceilimgs are drywall. 
 *The cost of repairs for components that may be damaged by surges can far exceed the cost of surge protectors
Measured temperature split and static pressure 
Inspected drains; cleared EZ trap, 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. Good

AC system operating well at this time.
Barry P.
Barry P. Checked in
Completed AC tune up for 4 Ton Goodman AC system Furnace is 9 years old. AC is approximately 3 years old Replaced 16x20x1 filter with one provided by homeowner Indoor and outdoor coils in good condition Inspected wiring, controls, electric motors and components; left estimates for surge protectors. The Y conductor between the thermostat and the indoor equipment control is shorted and the green conductor is therefore used for the cooling contact. There is no way of controlling the fan. The only way to address this is to install a thermostat with an EIM. A wire pull is not feasible. Wire is anchored and basement ceilimgs are drywall. *The cost of repairs for components that may be damaged by surges can far exceed the cost of surge protectors Measured temperature split and static pressure Inspected drains; cleared EZ trap, Checked integrity of compressor motor (mega ohm test) Assessed refrigerant charge checked pressures. Good AC system operating well at this time.
Landenberg, PA 19350
Completed AC tune up for 3 Ton Trane inverter heat pump system
System installed August 13, 2025

Replaced 24x24x1 filter; I left a 12x12x1, homeowner will replace 
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components;
Measured temperature split and static pressure 
Inspected drains; cleared  EZ trap, added treatment tabs to drain pan. 

Assessed refrigerant charge checked pressures. 

AC system operating well at this time.
Completed AC tune up for 3 Ton Trane inverter heat pump system
System installed August 13, 2025

Replaced 24x24x1 filter; I left a 12x12x1, homeowner will replace 
Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components;
Measured temperature split and static pressure 
Inspected drains; cleared  EZ trap, added treatment tabs to drain pan. 

Assessed refrigerant charge checked pressures. 

AC system operating well at this time.
Barry P.
Barry P. Checked in
Completed AC tune up for 3 Ton Trane inverter heat pump system System installed August 13, 2025 Replaced 24x24x1 filter; I left a 12x12x1, homeowner will replace Indoor and outdoor coils in good condition Inspected wiring, controls, electric motors and components; Measured temperature split and static pressure Inspected drains; cleared EZ trap, added treatment tabs to drain pan. Assessed refrigerant charge checked pressures. AC system operating well at this time.
Landenberg, PA 19350
Completed heat tune up for 100,000 BTU natural gas furnace.
(Furnace installed Oct. 2022; AC Installed July 2019)

Replaced 16x25x1 filter; was very dirty recommend replacing once every 2-3 months provided estimate for Air ranger electrostatic filter. This filter assembly powered by 24V acts as a MERV 14 filter. Replace media every 3-4 months. 

Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimate for surge protector for outdoor equipment circuit
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked mainofold gas pressure
Inspected drain and pump. Cleared EZ trap and flushed with water. System does not have a wet switch. This switch would shut equipment down if water makes its way on floor near equipment. Provided email estim
Completed heat tune up for 100,000 BTU natural gas furnace.
(Furnace installed Oct. 2022; AC Installed July 2019)

Replaced 16x25x1 filter; was very dirty recommend replacing once every 2-3 months provided estimate for Air ranger electrostatic filter. This filter assembly powered by 24V acts as a MERV 14 filter. Replace media every 3-4 months. 

Indoor and outdoor coils in good condition 
Inspected wiring, controls, electric motors and components; left estimate for surge protector for outdoor equipment circuit
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked mainofold gas pressure
Inspected drain and pump. Cleared EZ trap and flushed with water. System does not have a wet switch. This switch would shut equipment down if water makes its way on floor near equipment. Provided email estim
Barry P.
Barry P. Checked in
Completed heat tune up for 100,000 BTU natural gas furnace. (Furnace installed Oct. 2022; AC Installed July 2019) Replaced 16x25x1 filter; was very dirty recommend replacing once every 2-3 months provided estimate for Air ranger electrostatic filter. This filter assembly powered by 24V acts as a MERV 14 filter. Replace media every 3-4 months. Indoor and outdoor coils in good condition Inspected wiring, controls, electric motors and components; left estimate for surge protector for outdoor equipment circuit Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses Inspected hot surface ignitor and verified resistance with meter Cleaned flame sensor and verified flame rectification circuit Measured temperature rise and static pressure Checked mainofold gas pressure Inspected drain and pump. Cleared EZ trap and flushed with water. System does not have a wet switch. This switch would shut equipment down if water makes its way on floor near equipment. Provided email estim
Landenberg, PA 19350
Completed AC tune up for 5 Ton Lennox heat pump system. Equipment is propane furnace/heat pump hybrid 
System is 12 years old. 

Filter Replaced in February; in good condition 
Indoor coil had refrigerant oil on the top right side. Conducted electronic leak search and found leak at top of A coil. Showed homeowner video of this. 
Inspected wiring, controls, electric motors and components; left estimates for surge protectors 
Measured temperature split and static pressure 
Inspected drains; drain, tested pump; added treatment tabs to pump. Left previous estimate to replace pump and tubing. 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. 2.8° Subcooling. Refrigerant pressures and date indicate and undercharge which correlates to finding leak at indoor coil. 

Provided 2 estimates
1. Charge system up to 2# R410A refrigerant. There is no guarantee how long refrigerant will last considering leak.
2. Replace indoor coil. This is also not
Completed AC tune up for 5 Ton Lennox heat pump system. Equipment is propane furnace/heat pump hybrid 
System is 12 years old. 

Filter Replaced in February; in good condition 
Indoor coil had refrigerant oil on the top right side. Conducted electronic leak search and found leak at top of A coil. Showed homeowner video of this. 
Inspected wiring, controls, electric motors and components; left estimates for surge protectors 
Measured temperature split and static pressure 
Inspected drains; drain, tested pump; added treatment tabs to pump. Left previous estimate to replace pump and tubing. 
Checked integrity of compressor motor (mega ohm test)

Assessed refrigerant charge checked pressures. 2.8° Subcooling. Refrigerant pressures and date indicate and undercharge which correlates to finding leak at indoor coil. 

Provided 2 estimates
1. Charge system up to 2# R410A refrigerant. There is no guarantee how long refrigerant will last considering leak.
2. Replace indoor coil. This is also not
Barry P.
Barry P. Checked in
Completed AC tune up for 5 Ton Lennox heat pump system. Equipment is propane furnace/heat pump hybrid System is 12 years old. Filter Replaced in February; in good condition Indoor coil had refrigerant oil on the top right side. Conducted electronic leak search and found leak at top of A coil. Showed homeowner video of this. Inspected wiring, controls, electric motors and components; left estimates for surge protectors Measured temperature split and static pressure Inspected drains; drain, tested pump; added treatment tabs to pump. Left previous estimate to replace pump and tubing. Checked integrity of compressor motor (mega ohm test) Assessed refrigerant charge checked pressures. 2.8° Subcooling. Refrigerant pressures and date indicate and undercharge which correlates to finding leak at indoor coil. Provided 2 estimates 1. Charge system up to 2# R410A refrigerant. There is no guarantee how long refrigerant will last considering leak. 2. Replace indoor coil. This is also not
Landenberg, PA 19350

Completed heat tune up for propane furnace. System is 12 years old. 

Replaced 20x25x5 filter provided by homeowners
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked wiring, controls, electric motors and components; there are no surge protectors; left estimate for a surge protector for each of the 2 main circuits of system. Also provided estimate for Honeywell S1200 thermostat for better control of aux heat lockout. Current thermostat is a NEST. 
Checked manifold gas pressure
Inspected drain and pump. As previously noted vinyl discharge tubing of condensate pump is in bad condition. Left estimate to replace condensate pump and vinyl tubing. We will run new vinyl tubing to the 3” plumbing to make freeze proof will allow for use of humidifier. As of last couple years humidifier is not

Completed heat tune up for propane furnace. System is 12 years old. 

Replaced 20x25x5 filter provided by homeowners
Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses
Inspected hot surface ignitor and verified resistance with meter
Cleaned flame sensor and verified flame rectification circuit
Measured temperature rise and static pressure
Checked wiring, controls, electric motors and components; there are no surge protectors; left estimate for a surge protector for each of the 2 main circuits of system. Also provided estimate for Honeywell S1200 thermostat for better control of aux heat lockout. Current thermostat is a NEST. 
Checked manifold gas pressure
Inspected drain and pump. As previously noted vinyl discharge tubing of condensate pump is in bad condition. Left estimate to replace condensate pump and vinyl tubing. We will run new vinyl tubing to the 3” plumbing to make freeze proof will allow for use of humidifier. As of last couple years humidifier is not
Barry P.
Barry P. Checked in
Completed heat tune up for propane furnace. System is 12 years old. Replaced 20x25x5 filter provided by homeowners Inspected heat exchanger, burners, flue pipe, inducer assembly and hoses Inspected hot surface ignitor and verified resistance with meter Cleaned flame sensor and verified flame rectification circuit Measured temperature rise and static pressure Checked wiring, controls, electric motors and components; there are no surge protectors; left estimate for a surge protector for each of the 2 main circuits of system. Also provided estimate for Honeywell S1200 thermostat for better control of aux heat lockout. Current thermostat is a NEST. Checked manifold gas pressure Inspected drain and pump. As previously noted vinyl discharge tubing of condensate pump is in bad condition. Left estimate to replace condensate pump and vinyl tubing. We will run new vinyl tubing to the 3” plumbing to make freeze proof will allow for use of humidifier. As of last couple years humidifier is not
Landenberg, PA 19350
Review
New heat pump
David - Landenberg, PA 19350
Review
Luis was here on time. He came on a Sunday night for which I am very thankful, and did an excellent job of getting my air back on very quickly.
Bonnie - Landenberg, PA 19350
Review
Very impressed. Called mid day with a concern. The office staff was helpful and efficient. Received same day service and an immediate fix. Would definitely recommend. Our tech Barry was quick efficient, fixed the issue and made suggestions. Thank you Barry and team.
DE storage - Landenberg, PA 19350
Review
I have used another company for the last 30+ years and when I needed this HVAC servicing quickly was told it would be sometime in September (now July). I asked a friend who they used that was reliable and they said "Barry with DiBoise" was their preferred technician and company by far. I called got an appointment quickly. Barry was not only extremely good technically but also was excellent at explaining to me why and how the service steps would help improve the operation of my HVAC as he performed the Service. I heartily recommend DiBoise and hope you are lucky enough also to get Barry!
Roszann - Landenberg, PA 19350
Review
Matt Arenz - Landenberg, PA 19350
Response from DiBiase Heating and Cooling Company:

Hi Matt! Thank you so much for leaving a 5-star review!

Review
Punctual, professional and pleasant.
M K - Landenberg, PA 19350
Response from DiBiase Heating and Cooling Company:

Hello! Thank you so much for the kind words! We're glad to hear you had a positive experience with our team. Being punctual, professional, and pleasant is exactly what we strive for at DiBiase Heating and Cooling. We appreciate your support!

Review
M K - Landenberg, PA 19350
Response from DiBiase Heating and Cooling Company:

Hello! Thank you so much for taking the time to leave a 5-star review!

Review
Service person Barry was incredible and super helpful in answering questions honestly without feeling as if he was trying to push a sale on me.
Zach - Landenberg, PA 19350
Review
Great service.
Marjorie - Landenberg, PA 19350
Review
Barry is great, professional, and friendly. I love that I always have the same technician.👍🏻
Matt - Landenberg, PA 19350
Review
Always knowlegeable and courteous.
Margie Ciunci - Landenberg, PA 19350
Response from DiBiase Heating and Cooling Company:

Hello Margie! Thanks so much for your continued trust and support! We're thrilled to hear that you find our team knowledgeable and courteous.

Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 610-873-1244 .

By pressing Submit I agree to receive phone, email, or text messages from DiBiase Heating and Cooling Company to the provided mobile number and also agree to the DiBiase Heating and Cooling Company terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next