Expert HVAC Service and More in Villanova, PA
DiBiase Heating and Cooling Company provides a full range of services to keep your home comfortable and efficient year-round in Villanova, PA. Whether you need HVAC repair, installation, or maintenance, we’ve got you covered. Our team also specializes in improving indoor air quality with air purifiers, humidifiers, and ductwork services. Looking for water heater solutions? We offer repairs and replacements for both tank and tankless systems. Additionally, our energy services, including air sealing, insulation, and energy audits, help homeowners save on utility costs while maximizing comfort. Whatever your home’s needs, DiBiase Heating and Cooling Company is here to deliver expert service.
Founded in 2008, DiBiase Heating and Cooling Company is a family-owned and operated company that’s committed to delivering honest, reliable service. We take pride in our expertise, offering certified technicians who provide top-quality HVAC, plumbing, and energy services. What sets us apart is our focus on process and integrity—we do the job right the first time, ensuring your home is always in good hands. Ready to experience the DiBiase difference? Call 610-873-1244 or contact us online today to schedule your service!
Recent Jobs and Reviews in Villanova, PA
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction with the service provided. Customers consistently express appreciation for the professionalism, efficiency, and expertise demonstrated by the technicians. A dominant theme throughout is the promptness of service, with many reviewers noting quick response times, same-day repairs, and technicians arriving within hours of initial contact. The technical staff receives particular praise for their knowledge and diagnostic abilities, with customers frequently highlighting how problems were identified and resolved quickly and effectively. Another recurring positive sentiment centers on communication and customer education—reviewers repeatedly commend technicians for taking time to explain issues in detail, offering multiple options based on budget considerations, and providing helpful maintenance tips for the future. The personable and friendly nature of the service providers is mentioned consistently, contributing to a welcoming and trustworthy experience. Customers also express relief and gratitude when seemingly major problems turn out to have simple solutions, appreciating the honesty and transparency demonstrated. The thoroughness of inspections and the quality of workmanship are additional strengths noted across multiple reviews. Overall, the tone is enthusiastically positive, with strong recommendations for both the company and individual technicians, and customers expressing confidence in requesting specific service providers for future needs.
Villanova, PA at a glance
DiBiase Heating and Cooling Company has completed 10 jobs in Villanova, PA between February 2026 and August 2026.
The 3 customer reviews shown here average 5.0 out of 5.
The most recent job was on August 25, 2026.
Our Local Reviews by City
- Ambler, PA (1)
- Ardmore, PA (1)
- Aston, PA (4)
- Atglen, PA (3)
- Avondale, PA (3)
- Berwyn, PA (4)
- Brookhaven, PA (6)
- Broomall, PA (8)
- Chadds Ford, PA (4)
- Chadds Ford Township, PA (1)
- Chester, PA (1)
- Chester Springs, PA (84)
- Chesterbrook, PA (5)
- Claymont, DE (2)
- Clifton Heights, PA (1)
- Coatesville, PA (240)
- Cochranville, PA (5)
- Collegeville, PA (6)
- Collingdale, PA (5)
- Conshohocken, PA (4)
- Devon, PA (5)
- Downingtown, PA (292)
- Eagleville, PA (3)
- East Fallowfield Township, PA (16)
- Edgmont Township, PA (1)
- Elverson, PA (7)
- Exton, PA (74)
- Folsom, PA (5)
- Gap, PA (3)
- Garnet Valley, PA (4)
- Gladwyne, PA (1)
- Glen Mills, PA (8)
- Glenmoore, PA (37)
- Glenolden, PA (1)
- Green Lane, PA (1)
- Gwynedd Valley, PA (1)
- Haverford, PA (2)
- Havertown, PA (10)
- Honey Brook, PA (45)
- Kennett Square, PA (57)
- King of Prussia, PA (10)
- Landenberg, PA (9)
- Lansdowne, PA (1)
- Leacock-Leola-Bareville, PA (1)
- Lincoln University, PA (4)
- Lionville, PA (1)
- Malvern, PA (41)
- Media, PA (12)
- Merion Station, PA (5)
- Morgantown, PA (12)
- Newtown Square, PA (12)
- Norristown, PA (5)
- Oxford, PA (9)
- Paoli, PA (23)
- Parkesburg, PA (25)
- Phoenixville, PA (18)
- Plymouth Meeting, PA (4)
- Pottstown, PA (28)
- Ridley Park, PA (3)
- Royersford, PA (4)
- Saint Davids, PA (1)
- Spring City, PA (9)
- Springfield, PA (12)
- Swarthmore, PA (3)
- Thornbury Township, PA (3)
- Thorndale, PA (15)
- Valley Township, PA (5)
- Villanova, PA (2)
- Wayne, PA (15)
- West Bradford Township, PA (44)
- West Brandywine Township, PA (8)
- West Chester, PA (160)
- West Grove, PA (4)
- Wilmington, DE (2)
Job Locations and Reviews
8/25/26. Installed Honeywell s1200 thermostat. Showed him how to use thermostat. Also found that there is (2) a/cs located on the premises and (1) gas boiler. Provided estimate for maintenance plan. Bill signed up for maintenance plan. The person that is responsible for the app was not on site. When we return to perform heat tune up will also need to connect to the internet at that time. A/c is working properly at time of service. Office to bill out.
Closed job. There were no notes added.
Issue is with the far first floor bedroom and the room immediately above it are remaining warm. There are (3) Thermostats in the building. 1st floor thermostat in the foyer/entrance controls the basement system. The other First floor thermostat (in the problem bedroom)7 on the opposite side of the building controls (2) booster fans only it does not have any control of the heating or cooling equipment. It is the second floor thermostat that controls the heating and cooling for this far first floor bedroom. So what happens is the second floor thermostat satisfies and those (2) rooms remain warm. This has not been brought to our attention because up to this point no one has used these rooms. It will not be easy to zone this from the ductwork because each supply duct will need its own damper and the tic is very tight. In fact there is an abandoned 8x8 damper. The best solution here is to install a (2) head Minisplit system. To allow for heating and cooling for these spaces. This wil
Luis 6-8-26 Performed ac tune up on two Amana systems 3 ton first floor and 2.5 second floor both units from 2017. Both 413 filters ok. Check all electrical connections and components, check drain system, air delivery and drain system, indoor and outdoor electrical components and coils, compressor and fan motor operation. Found second floor not working, (open capacitor) talked to father Jim and he approved replacement of capacitor for second floor. Check refrigerant levels and pressures for both units. Both unit registering little lower than normal numbers. I provided estimate to add refrigerant and dye. Father Jim approved adding refrigerant to both units and also add dye. After adding refrigerant and dye re test system pressures and compare before/after both units are running within manufacture standards. We will check for leaks during next visits.
Luis 3-16-26 customer called for noise, I inspect system operation. Noise is coming from return grill, I check ductwork system supply and return, air handler has a very hard to get to, final recommendation is replace duct system. Supervisor to come out and insect ductwork, this is the only way to fix issue. See notes from previous years. No charge warranty
Collected information to provide a propsal to replace ductwork in kneewall space
Equipment is 4 Ton AC with 90,000 BTU 2 stage natural gas furnace. 2 zones Lennox Harmony III zone board with discharge air sensor that opens the AC (outdoor unit) circuit when temp drops below 40° (2) Zones (2) Thermostats 1st Fl and 2nd floor (3) Dampers: (2)are 8x20 1st Fl (1) is 16x8 2nd Fl Formerly the other side of Y conductor at the furnace control was landed to DS on the zone board so only when dehumidification would call would the Y contact close on the indoor control and energize cooling blower speed. Zone panel is no longer energizing the dehumidification, so o wired to Y1 contact on zone board. Afterwards tested AC. Pressures ok. Capacitor is a 45/10uF reading ok on 45 but a little weak on the 10 (fan) side. Contactor is also pitted Provided estimate to replace both. During my time here today we discussed and I recommended replacing the system. Offered consultation but she will be too busy to be able to sit down for a consultation. I took notes and photos for Joe to
Good communication and excellent response time.
Luis 2-10-26 Replace OEM Furnace Control+Flame Sensor. Set up board to match existing heater. Test heater operation ok. Performed combustion test. Heater is now working correctly. Temperature inside house went from 53 F to 60F by the time I left. Customer had to leave the home prior, finishing up office to call customer to collect balance.
Luis 2-9-26 follow up visit found unit off on ground not conneted issue. Check ground and wiring, ground is good. reset unit and unit came on. Test operation, I see lot of wear on ignition system. Heat exchanger, burners and igniter. System is 14 years old. I would recommend replacing system. Heater needs new sensor and control board.
Great response time
Found furnace off. 90,000 BTU 2-stage Error code 112 “Furnace ground not detected.” Opened 4x4 box. There was a gap on the grounding wires. I Wire nutted These together however found 2x4 box that feeds furnace with an old cloth wire WITHOUT a ground. The only nearby available ground is from an outdoor lighting wiring box. I ran a 15’ length of MC wire between this box and the 4x4 box with the ground to provide a ground to the furnace. Error code still persisted. Based on Lennox troubleshooting forum. The game sensor connections can also be the source of this problem. I throughly cleaned the terminal that the wire connects to there was a decent amount of rust her put everything back together. Started system and no error codes presented themselves. We need to order control board but this isn’t guaranteed to solve problem.Left estimate to replace board and flame sensor. Strongly recommend having an electrician run a new feed wire from breaker panel to the furnace with its own gr